E43-364 · Welded/Cast Forming Dimensional Error · A tubesheet with 1200 holes at 32mm pitch, designed pitch 32±0.1, measured accumulated shift 1.8 · ★★★
Tubesheet build-up welding and drilling distortion accumulate a pitch error of 1.8mm, making tube insertion difficult.
[Mechanism] Build-up welding shrinkage on the thick tubesheet shifts the whole hole group, accumulating pitch error.
[Calculation] Accumulated deviation Δ≈n·δ=1200×0.0015≈1.8mm (each hole offset 0.0015 accumulates), 18× the tolerance of 0.1.
[Design Omission] No control of the build-up sequence or of welding before drilling — a design defect leading to pitch error.
1) Drill the datum hole group first, build up weld, then ream;
2) Build up weld symmetrically in segments to reduce shrinkage;
3) Use drill jigs/bushings to hold pitch;
4) Stress-relieve the tubesheet after welding;
5) CNC-drill to theoretical coordinates;
6) Measure pitch on a CMM;
7) Trial-insert tubes to verify;
8) Measure first-article pitch ≤0.1mm.
GB/T 151-2014 Heat exchangers