Problem Description

The robot's taught position was off by 2mm, so the weld deviated onto the base metal and lacked fusion

Root Cause

[Mechanism] A deviated taught point makes the torch stray onto the base metal, causing lack of fusion.
[Calculation] A 2mm positioning deviation shifts the bead, and lack of fusion weakens the joint.
[Design gap] No seam-tracking correction was performed.

Corrective Solution

① Laser seam tracking: use a laser seam-tracking system to correct the position and ensure alignment
② Fine-tune taught points: precisely adjust the robot's taught points to ensure accuracy
③ First-article trial weld: trial-weld the first part and check fusion to ensure quality
④ Real-time compensation: compensate for deviation in real time to stabilize the position
⑤ NDT for lack of fusion: use NDT to check for lack of fusion and detect it early
⑥ In-process inspection: check the positioning deviation and correct early
⑦ Positioning verification: confirm the position is accurate by trial welding
⑧ Standardize process: write the seam-tracking correction into the robot program, controlling at the source

Checklist

Reference

GB/T 19867.2-2008 Welding procedure specification for mechanized welding and automatic welding