E46-311 · Casting & Forging · Ductile Iron Casting · ★★★
A ductile iron casting of grade QT500-7 was poured after a 40-minute interval, so the inoculation faded; the matrix became a mixture of ferrite and cementite, and elongation was only 2% (should be ≥7%).
[Mechanism] The ferrosilicon inoculant decays over time in the iron; the graphite spheroidization and inoculation effect weaken, and carbides precipitate.
[Calculation] The effective inoculation time is about 15 minutes; beyond that the nodularity drops, cementite increases, and elongation falls roughly linearly with fade.
[Design gap] The pouring tempo and stream inoculation were not controlled.
① Stream inoculation: add a stream inoculant during pouring to offset fade
② Control the tempo: finish pouring within 15 minutes of treatment, and re-inoculate if it runs over
③ In-mold inoculation: use in-mold inoculant blocks to delay fade
④ Composition adjustment: control the residual magnesium and rare earths to stabilize spheroidization
⑤ Mechanical re-test: cast a tensile test bar and measure elongation, detecting problems early
⑥ Metallographic check: section the part to check the matrix and confirm the absence of cementite
⑦ Property verification: confirm the elongation meets specification by tensile data
⑧ Standardize process: write the inoculation time limit into the process card, controlling at the source
GB/T 1348-2009 Spheroidal graphite iron castings