E46-349 · Casting & Forging · High-Manganese Steel Casting · ★★★
After water toughening, a high-manganese steel casting had insufficient hardness (should be ≥HB180) and wore rapidly because the carbides had not fully dissolved.
[Mechanism] A low water-toughening temperature or slow cooling leaves carbides undissolved in the austenite, degrading performance.
[Calculation] Below the critical water-toughening temperature carbides remain, while slow cooling precipitates carbides.
[Design gap] The water-toughening temperature and quench-in rate were not controlled.
① Control water-toughening temperature: heat to the temperature at which carbides fully dissolve
② Quench quickly: transfer rapidly into water after discharge to prevent carbide precipitation
③ Control soaking: soak long enough to homogenize
④ Check hardness: measure hardness after water toughening, detecting problems early
⑤ Metallographic check: inspect for residual carbides
⑥ Reprocess: re-water-toughen parts that fall short
⑦ Performance verification: confirm compliance by hardness
⑧ Standardize process: write the water-toughening specification into the process card, controlling at the source
GB/T 5680-2010 High manganese steel castings