E46-353 · Surface Treatment & Coating · Steel Fastener · ★★
After phosphating, a steel part had a mottled coating with bare spots; salt spray showed rust spots at 48h (should be 96h), because the bath total acidity varied widely and was not titrated on a fixed schedule.
[Mechanism] Low total acidity slows the phosphating reaction and thins the coating, while high free acid over-etches the surface.
[Calculation] Total acidity should be held at 25-35 points and free acid at 1.5-3 points; a wrong ratio gives an uneven coating.
[Design gap] No scheduled titration was set up to adjust the acid ratio.
① Titrate on schedule: titrate total acidity and free acid every shift to control the ratio
② Adjust the acid ratio: add phosphating solution or neutralizer to reach the standard
③ Control temperature: hold the phosphating bath at 40℃ to stabilize coating formation
④ Check the acid ratio: use titration to check it, detecting problems early
⑤ Re-phosphate: strip off the poor coating and re-phosphate to restore evenness
⑥ Control contamination: remove oil and dirt to keep them out of the bath and stay clean
⑦ Coating weight verification: confirm the coating weight meets specification by the gravimetric method, verified by data
⑧ Standardize process: write the titration frequency into the bath management card, controlling at the source
GB/T 6807-2001 Phosphating of iron and steel workpieces prior to painting