E46-404 · Commissioning & Run-In · Pump unit coupling · ★★★
The pump and motor were directly connected with a flexible coupling, and the unit was run without alignment; vibration velocity exceeded 7.1mm/s and the anchor bolts loosened.
[Mechanism] Skew between the two shaft centerlines subjects the coupling to cyclic bending moments, exciting twice-frequency vibration.
[Calculation] At a 0.3mm radial offset the added bending moment pushes the vibration velocity to three times the standard.
[Design gap] Alignment was not measured and adjusted with a dial gauge.
① Dial-gauge alignment: measure the radial and face offsets with a dial gauge and hold them within 0.05mm
② Adjust shims: add or remove motor base shims to adjust the height and eliminate parallel offset
③ Adjust axially: move the motor to eliminate the face gap and control the angular offset
④ Tighten in steps: tighten one end's bolts first and re-measure to prevent drifting after tightening
⑤ Re-measure: re-measure the alignment before coupling up to confirm stability
⑥ Measure vibration: measure the vibration velocity at no load and re-align above 4.5mm/s
⑦ Quality verification: confirm acceptance by the alignment record and vibration value, confirmed by data
⑧ Standardize process: write the alignment requirements into the installation and commissioning card, controlling at the source
GB/T 3852-2017 Couplings - Shaft holes and connections