E46-407 · Commissioning & Run-In · General reduction drive · ★★
The unit passed its no-load test run merely by turning over and was handed over; a week into service the bearing temperature rise reached an abnormal 70K and the grease carbonized and failed.
[Mechanism] Without monitoring the temperature rise during the test run, early excessive friction or poor lubrication goes unnoticed.
[Calculation] A temperature rise above 40K is the warning level, and at 70K the grease base carbonizes and loses lubrication.
[Design gap] Temperature-rise monitoring was not listed as a test-run item.
① Measure temperature periodically: check the bearing temperature rise every 30 minutes during the no-load test run and stop if it exceeds 40K
② Run in speed steps: test from low to high in steps, recording the temperature at each step
③ Grease check: after the test run, open the cover to check the grease for carbonization or blackening
④ Listen for noise: check the drive for periodic abnormal noise and investigate any anomaly
⑤ Measure vibration: measure the body vibration to rule out misalignment
⑥ Record all: record the complete temperature-rise curve as a baseline
⑦ Quality verification: confirm acceptance by temperature rise and grease condition, confirmed by data
⑧ Standardize process: write temperature-rise monitoring into the test-run outline, controlling at the source
GB/T 6404.1-2005 Acceptance code for gear units