E46-408 · Commissioning & Run-In · Gearbox · ★★
After run-in the gearbox was put into service without changing the oil; the metal debris inside circulated with the oil and after 3 days the tooth flanks showed pitting and spalling.
[Mechanism] The wear debris from run-in acts as an abrasive, and continuous circulation worsens abrasive wear.
[Calculation] When the debris concentration in the oil exceeds 50 mg/L the wear rate rises several-fold.
[Design gap] No oil change and cleaning was specified after run-in.
① Always change after run-in: drain the oil and clean the housing immediately at the end of run-in, then refill with new oil
② Check the magnetic plug: inspect the iron chips on the magnetic plug and extend run-in if excessive
③ Clean the filter: clean the suction strainer and magnetic element when changing the oil
④ Oil sample check: sample the new oil for cleanliness before pouring and only pour when it meets spec
⑤ Verify the grade: confirm the oil grade and viscosity match the drawing and do not mix grades
⑥ Record all: record the oil change volume and batch for traceability
⑦ Quality verification: confirm acceptance by oil sample cleanliness, confirmed by data
⑧ Standardize process: write the post-run-in oil change into the maintenance procedure, controlling at the source
GB/T 5903-2011 Industrial enclosed gear oils