E46-420 · Commissioning & Run-In · Diaphragm coupling · ★★
During installation of the diaphragm coupling the spacer was not aligned and the bolts were not preloaded, so in operation the diaphragm took extra bending moment and fatigued to fracture.
[Mechanism] A wrong axial gap between the two coupling halves bends the diaphragm, and loose bolts make the loading uneven.
[Calculation] When the gap deviation exceeds 2mm the additional stress in the diaphragm exceeds its fatigue limit.
[Design gap] The gap was not measured and the bolts were not preloaded to torque.
① Measure the gap: measure the gap between the two coupling halves to the drawing and keep it within tolerance
② Align: align the spacer with a process shaft or a straightedge to prevent misalignment
③ Preload: tighten the bolts in a diagonal cross pattern in several passes to the torque value
④ Re-measure: re-measure the gap and concentricity after tightening, and rotate only once they are stable
⑤ Listen: run and listen to the diaphragm for abnormal noise and stop immediately if there is any
⑥ Record: record the gap and the torque for traceability
⑦ Quality verification: confirm acceptance by gap and torque, confirmed by data
⑧ Standardize process: write the preloading step into the installation card, controlling at the source
GB/T 3852-2017 Couplings - Shaft holes and connections