E46-422 · Commissioning & Run-In · Centrifugal fan · ★★★
The fan impeller was installed and trial-run after welding without dynamic balancing; the vibration severity reached 9mm/s and the anchor-bolt welds cracked.
[Mechanism] Mass eccentricity of the impeller generates a centrifugal exciting force that grows with speed.
[Calculation] A 10 g eccentricity at 1500 rpm produces a centrifugal force of about 25 N, exceeding the allowance.
[Design gap] No dynamic balancing correction was performed.
① Mandatory balancing: after welding, balance the impeller on a balancing machine to better than grade G6.3
② Correct weight: remove material from or add balance weights to the wheel disc to bring the eccentricity within limits
③ Re-measure: re-measure the residual unbalance after balancing
④ Tighten blades: confirm that the blade-to-disc connections are not loose
⑤ Vibration test: with the impeller installed, run unloaded and measure vibration; rebalance if it exceeds 4.5mm/s
⑥ Record: record the unbalance amount and the balance-weight positions
⑦ Quality verification: confirm acceptance by balance grade and vibration value, confirmed by data
⑧ Standardize process: write dynamic balancing into the impeller process, controlling at the source
GB/T 9239.1-2006 Mechanical vibration - Balance quality requirements for rotors in a constant state