E46-438 · Commissioning & Run-In · Hydraulic piping · ★★
The piping seals were not rechecked after run-in; one week into service a joint seeped oil, the oil level dropped and the pump drew air with abnormal noise.
[Mechanism] Run-in vibration loosens joints that were not properly tightened, and small leaks accumulate into oil loss.
[Calculation] Once the seepage rate exceeds the make-up rate the oil level drops and the pump draws air.
[Design gap] No pressure-holding seal recheck was done after run-in.
① Pressure-hold check: after run-in hold system pressure and check every joint for seepage
② Retighten: retighten slightly seeping joints to the specified torque while pressure is held
③ Wipe clean: wipe the joints with a white cloth and check for oil traces; no traces means acceptable
④ Oil level: check that the reservoir level does not drop before and after pressure holding
⑤ Leak test: spray leak-detection fluid on suspect points and watch for bubbles
⑥ Record: record the holding pressure and the seepage points
⑦ Quality verification: confirm acceptance by holding pressure without seepage, confirmed by data
⑧ Standardize process: write the seal recheck into the commissioning sheet, controlling at the source
GB/T 3766-2015 General technical conditions for hydraulic systems