Casting wall thickness should be as uniform as possible, avoiding heavy sections that cause shrinkage cavities and porosity.
Junctions of different wall thicknesses should have a transition fillet or a gradual taper.
Minimum wall thickness of cast iron parts: 3~5mm (sand casting)
Minimum wall thickness of cast steel parts: 5~8mm
Minimum wall thickness of aluminium alloy castings: 2~3mm
All internal and external corners must have a casting fillet, to avoid sharp corners that cause stress concentration and cracks.
Internal fillet R=(0.2~0.3)× wall thickness
External fillet R=(0.15~0.2)× wall thickness
Surfaces perpendicular to the parting line must be given a draft angle.
External wall draft angle: 1°~3°
Internal wall draft angle: 2°~5°
Rib thickness should not exceed 0.7~0.8 times the adjacent wall thickness
Rib layout should avoid intersections that form hot spots
Rib height generally should not exceed 5 times the wall thickness
Arrange wall junctions in a T shape rather than a cross shape wherever possible
Related quick references: Tolerances & FitsSurface RoughnessMaterial Heat TreatmentGeometrical TolerancesDimension ChainsWelded StructuresSheet Metal StructuresShafting DesignSeal DesignMaterial SelectionHeat TreatmentDatum ReferencingTolerance Principles