T = 9550·P/n
T — torque (N·m)
P — power (kW)
n — speed (r/min)
P = T·ω = T·2πn/60
T = 60P/(2πn) = 9.549P/n (W,r/min)
= 9550·P/n (kW, r/min)
1. 3-phase induction motor
Synchronous speed n1 = 60 f / p
f — supply frequency (50 Hz)
p — pole pairs (2-pole p = 1, 4-pole p = 2)
Rated speed nN = n1 dot (1 - s)
s — slip (0.02~0.06)
2-pole (sync 3000): rated 2880~2940
4-pole (sync 1500): rated 1440~1470
6-pole (sync 1000): rated 960~980
8-pole (sync 750): rated 720~735
2. DC motor
n = (U-Ia·Ra)/(Ke·Φ)
Speed control: vary U (voltage) or vary Phi (field weakening)
3. Servo motor
Rated speed usually 3000 / 1500 / 1000 rpm
Peak torque = 2~3x rated torque
4. Stepper motor
Speed = 60 x frequency / (steps x microstep)
Holding torque large at low speed, decays severely at high speed
Induction motor starting torque = 1.5~2.5x rated
Starting current = 5~7x rated
Y-Delta start:
Starting torque = 1/3 direct start
Starting current = 1/3 direct start
n = 60f·(1-s)/p
VFD adjusts f to control speed
Constant V/f control keeps flux constant
4-pole induction motor P = 5.5 kW, n = 1440 rpm
T = 9550×5.5/1440 = 36.5N·m
Starting torque approx 2 x 36.5 = 73 N.m
Starting current approx 6 x IN = 6 x 11.6 = 69.6 A
Ratio of motor speed to load demand speed = i
Select reducer ratio i so motor runs near rated speed
P = Tload·nload/(9550·η·i)
η — transmission efficiency
i — reduction ratio
Consider duty factor K = 1.1~1.5
P_motor = K dot P
R = Jload'/Jmotor = Jload/(i²·Jmotor)
Jload — total load-end inertia (kg.m^2)
Jmotor — motor rotor inertia (kg.m^2)
i — reduction ratio
Recommended values:
Servo motor: R <= 10 (best <5)
Stepper motor: R <= 30 (best <10)
1. Rotary body:
Solid cylinder J = 0.5 dot m dot r^2
Ring J = 0.5 dot m dot (r1^2 + r2^2)
Slender rod (about center) J = m dot L^2 / 12
Slender rod (about end) J = m dot L^2 / 3
2. Linear motion (via screw reflection):
J = m dot (L/(2pi))^2 (screw lead L)
3. Via gear / timing belt reflection:
J' = J/i²
Tacc = (Jmotor + Jload')·α
α = 2π·n/(60·tacc) (rad/s²)
n — target speed (rpm)
t_acc — acceleration time (s)
Tpeak = Tacc + Tfriction + Tload
T_friction = mu dot m dot g dot (L/(2pi i)) (screw drive)
Tload = F·(L/(2πi·η))
1. T_peak <= T_max (motor peak torque)
2. T_rms <= T_N (rated torque)
3. n_max <= n_motor_max
4. R <= recommended
Trms = √(Σ(Ti²·ti)/Σti)
Include accel / const / decel / rest segments
i = n_motor_max / n_load_max
Or by inertia ratio: i >= sqrt(Jload / (R dot Jmotor))
Increasing i:
- Lowers inertia ratio
- Lowers required motor torque
- But raises motor speed (may exceed limit)
Load m = 50 kg, screw lead L = 10 mm, eta = 0.9
v = 1 m/s, accel time 0.2 s
Jload = 50×(0.01/(2π))² = 1.27×10⁻⁴ kg·m²
Select motor Jmotor = 0.5 x 10^-4, ratio i = 1
R=1.27/0.5=2.53 < 10 ✓
alpha = 2pi x 60 x 1 / (0.2 x 60) = 31.4 rad/s^2 (assume n = 600)
Tacc=(0.5+1.27)e-4×31.4=0.0556N·m
Tfriction=0.1×50×9.81×0.01/(2π×0.9)=0.087N·m
Tpeak=0.0556+0.087=0.143N·m
Select 400 W servo (TN = 1.27, Tmax = 3.8) sufficient
u(t) = Kp·e(t) + Ki·∫e(t)dt + Kd·de(t)/dt
or u(t) = Kp dot [e(t) + (1/Ti) dot integral e(t) dt + Td dot de(t)/dt]
Kp — proportional gain
Ki — integral gain = Kp / Ti
Kd — derivative gain = Kp dot Td
Ti — integral time
Td — derivative time
e(t) — error = setpoint - feedback
u(k) = Kp·e(k) + Ki·Ts·Σe(i) + Kd·(e(k)-e(k-1))/Ts
Ts — sampling period
Compute u(k) directly
Integral term needs anti-windup
Δu = Kp(e(k)-e(k-1)) + Ki·Ts·e(k) + Kd/Ts·(e(k)-2e(k-1)+e(k-2))
u(k) = u(k-1) + Δu
Pros: no accumulated error, smooth switching
1. Critical oscillation method
P control only, increase Kp until sustained oscillation
Record critical gain Ku and oscillation period Tu
PID parameters:
Kp = 0.6Ku
Ti = 0.5Tu
Td = 0.125Tu
PI control: Kp = 0.45 Ku, Ti = 0.83 Tu
P control: Kp = 0.5 Ku
2. Step response method
Measure open-loop step response
Lag tau, slope R
PID: Kp=1.2/(Rτ), Ti=2τ, Td=0.5τ
PI: Kp=0.9/(Rτ), Ti=3.3τ
Increase Kp: fast response, large overshoot, possible oscillation
Increase Ki: eliminates steady-state error, but more overshoot
Increase Kd: reduces overshoot, but noise sensitive
1. P first, then I, then D
2. Kp from small to large until fast but no overshoot
3. Add I to eliminate steady-state error
4. Add D to reduce overshoot
5. Fine-tune to optimal
Stop integral accumulation when output saturates
Or use conditional integration / back-calculation
Temperature control: Kp = 2.0, Ki = 0.1, Kd = 5.0
Setpoint 100 C, feedback 98 C
e=2
Integral term (accumulated) = -0.5 (assume previously low)
Derivative term = (2 - 3)/0.1 = -10 (assume last error 3)
u = 2 x 2 + 0.1 x (-0.5) + 5 x (-10) = 4 - 0.05 - 50 = -46 (abnormal)
Shows derivative too large is noise sensitive
Temperature / pressure / flow / level control
Servo position loop / speed loop
UAV attitude control
F = B²·A/(2μ0) = (B²·A)/(8π×10⁻⁷) (SI)
B — air-gap flux density (T)
A — pole area (m^2)
mu0 — vacuum permeability = 4pi x 10^-7 H/m
Rough estimate:
F approx 40 dot B^2 dot A (N, B in T, A in m^2)
F ≈ 4·B²·A (kgf)
B=1T, A=1cm²: F≈4N
B=1.5T: F≈9N
F = NI = H·l = Φ·Rm
N — coil turns
I — current (A)
H — magnetic field intensity (A/m)
l — magnetic path length (m)
Phi — magnetic flux (Wb)
Rm — reluctance = l / (mu dot A)
Total magnetomotive force = Sigma H l (each segment) + Hg dot g (air gap)
Air-gap magnetic drop usually 80~90%
NI = Bg·g/μ0 + Σ(Hi·li)
Bg — air-gap flux density
g — air-gap length
Induced EMF e = -N dot dPhi/dt
DC electromagnet coil:
U = I dot R (steady state)
Current rises gradually with inductance L at energizing
tau = L / R (time constant)
AC electromagnet:
U = 4.44 dot f dot N dot Phi_m (RMS)
Phi_m — flux amplitude
1. DC electromagnet
Constant force, low loss
Needs arc suppressor (DC arc hard to extinguish)
2. AC electromagnet
Force pulsation (2x line freq), needs shading coil to remove vibration
Has iron loss (eddy + hysteresis)
Large current at energizing (inrush)
DC electromagnet: air gap g = 2 mm, A = 10 cm^2, B = 1.2 T
F = 40 x 1.2^2 x 0.001 = 0.058 N = 5.8 gf -> too small
Increase A = 50 cm^2: F = 40 x 1.44 x 0.005 = 0.288 N = 29 gf
Real electromagnets use high-B material (silicon steel Bm = 1.5~1.8 T)
F can reach tens to hundreds of N
Relay / contactor
Solenoid valve
Electromagnetic brake / clutch
Magnetic separator
Electromagnetic chuck (lifting)
(1) Open-loop position control (no encoder)
(2) High torque at low speed
(3) Torque decays severely at high speed (inductance effect)
(4) Has resonance region (unstable at low speed)
(5) Errors do not accumulate
Standard: 1.8 deg/step (200 steps/rev)
High resolution: 0.9 deg (400 steps/rev)
5-phase: 0.72 deg (500 steps/rev)
After microstepping:
Actual Step Angle = Standard Step Angle / Microstep Count
1.8 deg / 16 microstep = 0.1125 deg (3200 steps/rev)
Holding torque Th (max torque at standstill)
Running torque drops sharply as speed increases
n=0: T=Th
n=200rpm: T≈0.9Th
n=1000rpm: T≈0.4Th
n=2000rpm: T≈0.15Th
No-load start frequency: fs (typical 1~3 kHz pulses)
Loaded start frequency: fs' = fs dot sqrt(1 - (Tl/Th)^2)
Above start frequency needs gradual freq ramp
Current determines torque (Th proportional I)
Voltage determines high-speed performance (high U -> holds torque at high speed)
Common config:
NEMA 23 stepper: 2~3 A, 24~48 V
NEMA 34 stepper: 4~6 A, 48~80 V
NEMA 42 stepper: 6~8 A, 60~100 V
(1) Compute load torque Tl (incl accel + friction + load)
(2) Select Th = Tl / 0.5~0.7 (margin)
(3) Determine max speed nmax (from T-n curve T(nmax) >= Tl)
(4) Verify inertia ratio (Jload/Jrotor <= 30)
(5) Select driver and supply
Low-freq resonance region (typically 100~200 Hz pulses)
May lose steps or vibrate in this region
Solutions:
(1) Use microstepping (smaller step angle)
(2) Add damper
(3) Avoid operating at resonant speed
(4) Use closed-loop stepper with feedback
(1) Sudden speed change (exceeds start frequency)
(2) Load exceeds torque
(3) Insufficient supply voltage
(4) Excessive inertia
Stepper: low cost, open-loop, high low-speed torque, prone to resonance
Servo: high cost, closed-loop, good high-speed, smooth
Stepper suits: low-speed positioning, dispensing, engraving, 3D printing
Servo suits: high-speed precision, continuous motion, CNC
Other quick references in this series:Mechanics FundamentalsFluid MechanicsVibrationThermodynamicsElectrical FundamentalsQuick-Calc FormulasHydraulics / Inertia CalculationGear StrengthShaft StrengthKeyed ConnectionsSpringsBolt StrengthWeld StrengthBeam and Plate Bending