Standard Equipment · Pressure Vessels (Quick Reference)
Cylinder Wall Thickness Calculation (GB150)
【Internal Pressure Cylinder Wall Thickness】
δ=P×D_i/(2×[σ]^t×φ-P)
P design pressure (MPa), D_i internal diameter (mm)
[σ]^t allowable stress at the design temperature (MPa)
φ weld joint coefficient (0.7~1.0)
【Calculation Case】
P=2.0MPa, D_i=1000mm, Q345R, [σ]=170MPa, φ=0.85
δ=2.0×1000/(2×170×0.85-2.0)=7.0mm
Add a corrosion allowance of 1.5mm → nominal wall thickness 10mm
【External Pressure Verification】
A stability verification is required; when δ_e/D_o is small, stiffening rings are needed
Head Design and Selection
【Ellipsoidal Head】(most widely used)
a/b=2 (standard type)
δ=P×D_i×K/(2×[σ]^t×φ-0.5P)
Straight flange height h≥25mm
【Spherical Head】
The wall thickness is about 50% of an ellipsoidal head
But manufacturing is difficult and it occupies more space
【Conical Head】
Half cone angle α≤60°, a flange is needed when α>30°
Used for transitions between shells of different diameters / conical bottoms
【Selection Recommendations】
Atmospheric / low pressure: ellipsoidal head
High pressure: spherical head
Where product discharge is required: conical head
Nozzle Reinforcement Calculation Method (GB150)
【Area Replacement Method GB150】Opening weakened area A=d×δ
【Effective Reinforcement】Effective nozzle height h₁=min(√(d×δ_nt), actual height), shell reinforcement width B=max(2d, d+2δ_n+2δ_nt)
【Reinforcement Pad】Outer diameter D=2d, thickness ≤1.5 times the shell wall thickness, material the same as the shell
【No Reinforcement Required】When d≤0.14D and d≤89mm no separate reinforcement is needed
Flanged Connection Design Parameters
【Types】Flat plate PL for low pressure (≤2.5MPa), slip-on SO for medium pressure (≤6.3MPa), weld neck WN for high pressure (≥10MPa)
【Gaskets】Asbestos free T≤250℃ P≤2.5MPa, spiral wound T≤450℃ P≤25MPa, metal ring joint T≤600℃ P≤70MPa
【Preload】Torque T=K×F×d (K=0.2~0.3)
【Sealing Face】Flatness ≤0.5mm/m, gasket compression ratio 15%~25%
Stiffening Ring Design for External Pressure Vessels
【Instability】Critical pressure P_cr=2.6×E×(δ/D_o)^(5/2)/(L/D_o-0.45)
【Function】Divides the effective length into several sections to raise the critical pressure
【Ring Size】Required moment of inertia I_s=P×D_o³×L_s/(24×E)
【Spacing】L_s=(L/1.5)/(N+1), the stiffening rings are normally on the outside of the shell