Standard Equipment · Piping & Pipe Fittings (Quick Reference)
Pipe Wall Thickness Calculation (SCH Schedule)
【Wall Thickness】δ=P×D/(2×[σ]×φ+P)
【SCH Number】SCH=1000×P/[σ], common values SCH10/20/40/80/160
【Corrosion Allowance】Normally 1.5~3mm for general process service, 3~6mm for corrosive media
Pipeline Thermal Expansion Compensation Calculation
【Elongation】ΔL=α×L×Δt, for steel α=0.012mm/m·℃
【Case】L=30m carbon steel pipe Δt=200℃ → ΔL=72mm
【Compensation】U-shaped compensator 50~400mm, π-shaped is twice the U-shaped one, bellows compensator 10~50mm
【Cold Setting】Pre-stretch by ΔL/2 during installation to reduce the hot-state stress