Dropping parts and deforming parts with grippers are high-frequency faults on automated loading/unloading lines. This article gives the gripping force check formula for pneumatic grippers, a friction coefficient table for common materials, and a complete worked example; it back-calculates the single-jaw output force from the workpiece mass, acceleration, and safety factor, then selects the bore against the catalog, helping you select the right gripper specification in one pass and avoid the two pitfalls of air pressure fluctuation and acceleration conditions.
Parallel-jaw pneumatic grippers are widely used at automated loading/unloading stations (machining loading/unloading, injection molding part removal, lithium electrode sheet handling). Many engineers, when selecting a gripper, only check whether the stroke is sufficient and whether the mounting hole positions match, without checking the gripping force, and three types of problems appear on site:
The "gripping force" stated in a gripper catalog is the single-jaw output force at the rated air pressure (usually 0.5 MPa) at the midpoint of the stroke. In actual selection, first back-calculate from the workpiece conditions how much normal gripping force is required, then divide by the friction coefficient to obtain the single-jaw force requirement, and finally check against the catalog while keeping a margin.
The workpiece is held without falling by the static friction between the two jaws and the workpiece surface; the check formula is:
F_jaw × 2 × μ ≥ m × (g + a) × k
That is:
F_jaw ≥ m × (g + a) × k / (2 μ)
Parameter description:
| Symbol | Meaning | Unit |
|---|---|---|
| F_jaw | Normal gripping force of a single jaw on the workpiece | N |
| μ | Static friction coefficient between the jaw and the workpiece surface | — |
| m | Workpiece mass | kg |
| g | Gravitational acceleration, taken as 9.81 | m/s² |
| a | Maximum resultant acceleration of the manipulator (including the gravity-direction component) | m/s² |
| k | Safety factor, about 2 | — |
With symmetric two-jaw gripping there are two friction surfaces, so multiply by 2; if the workpiece rests on a locating block on one side and the gripper only provides one-sided clamping, do not multiply by 2.
For a preliminary engineering calculation, take values from the table below; for smooth oily surfaces take the lower limit, and for surfaces with rubber/polyurethane pads take the upper limit:
| Jaw material | Workpiece material | Static friction coefficient μ |
|---|---|---|
| Steel (smooth) | Steel | 0.15~0.25 |
| Steel (smooth) | Aluminum | 0.15~0.20 |
| Steel (with rubber pad) | Steel/aluminum | 0.30~0.50 |
| Polyurethane pad | Steel/aluminum | 0.40~0.60 |
| Resin jaws | Plastic parts | 0.30~0.45 |
Given conditions:
Step 1: Calculate the required friction holding force
F_hold = m × (g + a) × k = 2 × (9.81 + 5) × 2 = 59.2 N
Step 2: Back-calculate the single-jaw normal force
Symmetric two-jaw gripping, two friction surfaces:
F_jaw = F_hold / (2 × μ) = 59.2 / (2 × 0.30) = 98.7 N
That is, each jaw must provide a normal force of no less than 98.7 N on the workpiece surface.
Step 3: Select the gripper bore against the catalog
Checking a common parallel gripper catalog (0.5 MPa air supply, midpoint of stroke):
| Bore specification | Single-jaw output force (approx.) |
|---|---|
| 16 mm | 50~60 N |
| 20 mm | 90~110 N |
| 25 mm | 150~170 N |
A 20 mm bore gripper outputs about 100 N per jaw at 0.5 MPa, just covering 98.7 N with almost no margin; considering that the workshop air pressure may fluctuate to 0.4 MPa (output force dropping to about 80 N), directly select a 25 mm bore gripper, which outputs about 160 N per jaw, 1.6 times the actual single-jaw force requirement of 98.7 N — a sufficient margin.
1. Air pressure fluctuation must be taken into account. The catalog gripping force is the value at 0.5 MPa, while the actual workshop air supply often fluctuates between 0.4 and 0.6 MPa; during selection, look up the gripper output force at the minimum air pressure of 0.4 MPa, and do not select right at the rated value.
2. The gripping point should fall on a rigid section of the workpiece. When the overhanging section or a thin-wall area of the workpiece is gripped, local elastic deformation reduces the effective friction surface, and no matter how sufficient the calculated force, it will slip; choose the gripping point as close as possible to the locating face and where the wall thickness is uniform.
3. Take the resultant value for acceleration. The peak acceleration of a six-axis manipulator during startup, turning, and emergency stop is often 1.5–2 times the rated value; take a as the maximum resultant acceleration from trajectory simulation, and do not calculate it only from the acceleration of the constant-speed segment of horizontal movement.
1. Gripper force diagram: two jaws gripping the workpiece, marking the directions of the normal force F_jaw, the friction force μF_jaw, and the workpiece weight m g.
2. Gripper selection flowchart: workpiece mass/acceleration/friction coefficient → back-calculate the single-jaw force → look up the catalog at the minimum air pressure of 0.4 MPa → select the bore.
3. Comparison chart of common jaw types: the contact state on the workpiece surface of three jaws — smooth steel, with rubber pad, and polyurethane pad.
If you are stuck on structure, browse the complete-line 3D models in the "MOULDL Model Library (mouldl model library)" (such as pick-and-place machines and injection molding machines, with parts lists); for the data, double-check with the "BST Technical Handbook" to be safer.
This article was compiled by Baist Technology (BST) as a reference for mechanical selection.