The cylinder is the most widely used actuator in automated equipment. Common mistakes: setting the bore by rule of thumb, so it either cannot push or wastes compressed air; computing only the extend thrust but not the retract thrust; and not converting the air consumption, so the air compressor is sized wrong. This article gives a complete worked example along the chain of external load, required thrust, bore back-calculation, rounding to standards, load-ratio check, and air consumption estimate, with the basis aligned to ISO and the AirTAC model range. After reading it you can complete a single-cylinder sizing on your own.
The core of cylinder sizing is to first compute the external load accurately, then back-calculate the bore from the load ratio. For horizontal pushing the load is mainly friction; for vertical lifting include the self-weight; for off-center mounting convert to an additional resistance. Take the load ratio η as 0.3~0.5: the upper limit for low-speed smooth motion, the lower limit for high speed or impact.
Second, the extend and retract effective areas differ: the retract side excludes the piston-rod area and produces less thrust, so when the return stroke carries a load the retract side must be checked separately.
Third, air consumption: catalog volumes are at working pressure, so when sizing the air compressor they must be converted to standard-state free air; the piping is re-pressurized every stroke, and when the valve is far from the cylinder the piping volume can exceed the cylinder volume.
Core Formulas
Theoretical extend thrust: F_ext = P × π/4 × D²
Theoretical retract thrust: F_ret = P × π/4 × (D² − d²)
Required theoretical thrust: F_req = F_load / η
Bore back-calculation: D = SQRT(4 × F_req / (π × P))
Air consumption per cycle (standard state): V0 = (π/4 × D² × S + π/4 × (D² − d²) × S) × (P + 0.1) / 0.1
Air consumption per minute: q = V0 × n
Parameter description
| Parameter | Meaning | Unit |
|---|---|---|
| D | Bore | mm |
| d | Piston rod diameter | mm |
| S | Stroke | mm |
| P | Working gauge pressure | MPa |
| F_load | External load | N |
| η | Load ratio | — |
| n | Cycles per minute | cycles/min |
Recommended Value Table
| Item | Recommended value | Notes |
|---|---|---|
| Working pressure P | 0.4~0.6 MPa | Typically 0.5 |
| Load ratio η | 0.3~0.5 | Horizontal 0.4~0.5, high-speed impact 0.3, vertical 0.3 |
| Standard bore series | 20/25/32/40/50/63/80/100/125 mm | Round up |
| Piston rod diameter | 32 bore with φ16, 40 bore with φ16, 50 bore with φ20 | Per the SC model range |
| Cushion type | Choose air cushioning when the end speed exceeds 0.1 m/s | Rubber cushioning is only for low speed |
Complete Worked Example
Given: horizontal pushing of a workpiece, m=80 kg, sliding guide μ=0.2, stroke S=200 mm, P=0.5 MPa, 15 times per minute, valve-to-cylinder piping 5 m long with 6 mm ID, take η=0.4.
Step 1: compute the external load.F_load = μ × m × g = 0.2 × 80 × 9.81 = 156.96 N ≈ 157 N
Step 2: compute the required theoretical thrust.F_req = 157 / 0.4 = 392.4 N
Step 3: back-calculate the bore.D = SQRT(4 × 392.4 / (π × 0.5)) ≈ 31.6 mm, round up to the standard bore of 32 mm.
Step 4: check the load ratio and the retract thrust.
F_ext = 0.5 × π/4 × 32² = 402.1 N; actual load ratio = 157 / 402.1 = 0.39, acceptable.
Taking the piston rod at d=16 mm: F_ret = 0.5 × π/4 × (32² − 16²) = 301.6 N. In this case the return stroke is unloaded, so the margin is ample; if the return stroke carried a load, the retract-side load ratio would reach 0.52, near the upper limit, and a 40 bore would be advisable.
Step 5: estimate the air consumption.
V_ext = π/4 × 32² × 200 = 0.1609 L; V_ret = π/4 × (32² − 16²) × 200 = 0.1206 L.
Compression ratio = (0.5+0.1)/0.1 = 6; V0 = (0.1609 + 0.1206) × 6 = 1.689 NL/cycle; cylinder air consumption = 1.689 × 15 = 25.3 NL/min.
Piping volume = π/4 × 6² × 5000 = 0.1414 L, pressurized twice per cycle: V0_pipe = 0.1414 × 6 × 2 = 1.696 NL/cycle.
Total q = (1.689 + 1.696) × 15 ≈ 50.8 NL/min; size the air compressor with a 1.2~1.5 margin.
Conclusion:Select an SC32×200 standard cylinder (AirTAC model range) with air cushioning, supplied at 0.5 MPa, with an air consumption of about 51 NL/min.
If you have no idea for the structure, browse the full-line 3D models (chip mounters, inverters, etc., with parts lists) in the "MOULDL Model Library (mouldl Model Library)"; for data, check them again against the "BST Technical Handbook" to be safer.
This article was compiled by Baist Technology (BST) as a reference for mechanical selection.