For the electrolyte filling process of prismatic aluminum-shell cells, this article gives a complete worked example in four steps: "convert the fill quantity to volume → derive the flow rate from the cycle time → match pump displacement to the stroke rate → check accuracy". Readers can apply the formulas directly to select a ceramic-plunger metering pump and avoid common pitfalls such as back pressure and leakage.
Electrolyte filling is the key process that determines consistency in lithium-battery manufacturing: too large a deviation in the injected amount directly lowers cell capacity or makes cycle life plunge. The fill quantity per cell is usually 20~80 mL for prismatic aluminum-shell cells, 5~30 mL for pouch cells, and only 2~5 mL for cylindrical cells. Two kinds of mistakes are common in engineering: first, selecting the pump only by "how many milliliters per minute are needed" without checking the number of strokes and the accuracy within a single fill time, so the cycle gets faster but the fill accuracy falls to worse than ±2%; second, ignoring the piping back pressure and the valve response lag, so the pump outlet displacement does not match the actual liquid delivered at the valve port and the tolerance is exceeded.
On lithium-battery filling lines there are mainly two kinds of metering pump: ceramic-plunger and PTFE-diaphragm. The plunger type is rigid with repeatability down to ±0.3%, but plunger seal wear needs attention; the diaphragm type avoids oil contamination and resists corrosion well, but its absolute displacement is smaller and its accuracy slightly lower. For large fill volumes in prismatic aluminum shells, the plunger type is the first choice.
Core Formulas
Electrolyte volume:V = m / ρ, where m is the fill mass per cell (g) and ρ the electrolyte density (g/mL).
Required average flow rate:Q = V / t_inj, where t_inj is the effective fill time per cell (s). Convert to mL/min: Q = V(mL) / t_inj(s) × 60.
Pump displacement per stroke:V_s = (π/4) · d² · S, where d is the plunger diameter (mm) and S the plunger stroke (mm).
Strokes per minute:n = Q / V_s。
Average plunger speed:v = 2 · S · n / 60, in m/s; for a ceramic plunger v≤0.3 m/s is recommended.
Fill accuracy check: error per cell = pump repeatability (FS) × V, required ≤±1% × V.
Parameter description
| Parameter | Meaning | Unit |
|---|---|---|
| m | Fill mass per cell | g |
| ρ | Electrolyte density (commonly 1.20~1.25 for LiPF6 systems) | g/mL |
| V | Fill volume per cell | mL |
| t_inj | Effective fill time per cell | s |
| Q | Required average flow rate | mL/min |
| V_s | Pump displacement per stroke | mL |
| d | Plunger diameter | mm |
| S | Plunger stroke | mm |
| n | Stroke rate | cycles/min |
| v | Average plunger speed | m/s |
Recommended Value Table
| Item | Recommended value | Notes |
|---|---|---|
| Fill accuracy requirement | ±0.5%~±1% | ±1% for power cells, ±0.5% for consumer electronics |
| Electrolyte density ρ | 1.20~1.25 g/mL | Use the measured value from the supplier's COA |
| Plunger pump repeatability | ±0.2%~±0.5% FS | A servo-driven ceramic plunger can reach ±0.3% |
| Average plunger speed v | ≤0.3 m/s | High speed reduces accuracy and accelerates seal wear |
| Stroke rate n | 30~120 strokes/min | Too low gives large discharge pulsation, too high shortens life |
| Piping back pressure | ≤0.3 MPa | Back-pressure fluctuation translates directly into fill-quantity deviation |
Complete Worked Example
Given:For a prismatic aluminum-shell 50 Ah cell, the fill mass per cell is m=48 g, the electrolyte density ρ=1.20 g/mL, the filling cycle T=8 s per cell, of which the fill valve is open and actually delivering liquid for t_inj=4 s, and the fill accuracy requirement is ±1%.
Step 1: convert the fill volume per cell.
V = 48 / 1.20 = 40.0 mL。
Step 2: find the required average flow rate.
Q = V / t_inj = 40.0 / 4 = 10.0 mL/s = 600 mL/min。
Step 3: make a first selection of the pump displacement per stroke.
Taking the stroke rate n near 60 strokes/min (1 per second, for easy matching with the cam/servo cycle), try V_s=10 mL. This corresponds to a plunger diameter d=12 mm and stroke S=88 mm; check:
V_s = (π/4) × 12² × 88 = 9953 mm³ ≈ 9.95 mL。
Step 4: check the stroke rate and the plunger speed.
n = 600 / 9.95 = 60.3 strokes/min, within the recommended range of 30~120.
Average plunger speed v = 2 × 0.088 × 60.3 / 60 = 0.177 m/s, far below the 0.3 m/s limit.
Step 5: fill accuracy check.
Strokes within 4 s = 60.3 × 4 / 60 = 4.02 strokes; actual discharge = 4.02 × 9.95 = 40.0 mL.
Taking the pump repeatability as ±0.3% FS, the fill error per cell = ±0.3% × 40 = ±0.12 mL, relative error = 0.12/40 = ±0.3%, less than the ±1% requirement.
Conclusion:Select a ceramic-plunger metering pump with a plunger diameter of 12 mm, a stroke of 88 mm, a displacement per stroke of about 9.95 mL, and a servo-driven stroke rate of 60 strokes/min; it meets the filling requirement of 40 mL per cell, an 8 s cycle, and ±1% accuracy.
If you have no idea for the structure, browse the full-line 3D models (sorting machines, feeders, etc., with parts lists) in the "MOULDL Model Library (mouldl Model Library)"; for data, check them again against the "BST Technical Handbook" to be safer.
This article was compiled by Baist Technology (BST) as a reference for mechanical selection.