A battery plant had cold welds in ultrasonic metal welding of aluminum tabs to the cap plate, with a mean vertical pull-off force of 228N (standard ≥200N), a CPK of only 0.52, and a defect rate of about 6%. This article checks quantitative evidence item by item along five lines — horn knurling wear, welding parameter window, tab oxide layer, fixture clearance, and equipment rigidity — gives the horn dressing interval and improved parameter values, and includes a before-and-after comparison table, so that readers can use it to troubleshoot their own welding stations.
On a module line at a power battery plant, aluminum tabs (a 5-layer stack of 0.1mm aluminum foil) are ultrasonically metal-welded to a positive cap plate aluminum sheet; the horn is of the longitudinal-vibration type and the weld point size is 4mm×4mm. The process requires a vertical pull-off force ≥200N and a fracture that is cohesive failure of the material.
A July 2026 customer complaint: finished products showed tab open circuits after vibration testing. Sampling the welding station's products over 3 consecutive days and running a vertical pull-off test on each, 300 pieces in total, gave a mean tensile force of 228N with a standard deviation of 18N and a defect rate of 5.9% (about 6%) below 200N. Taking the one-sided specification of 200N, CPK=(228−200)/(3×18)=0.52, so the process capability is seriously insufficient.
Dissecting the cold-weld points: the cold welds were concentrated at the discharge-side edge of the horn knurling, accounting for about 60%; the fracture showed a silvery metallic luster but no material tearing, which is interface-separation-type cold welding, not a pull-apart after fusion. The first article of a new shift passed, and the defect rate began to rise after about 2 hours of continuous production.
Check item by item in the order "from easy to measure to hard to dismantle, from external to internal causes":
Check 1: surface condition of the horn and the anvil.
The horn was removed and its knurl height measured under a toolmaker's microscope. A new horn has a knurl height of 0.08mm; this horn had produced about 80,000 points continuously and the measured knurl height was only0.03mm, a wear rate of 62.5%. Once the knurling is worn flat it can no longer pierce the oxide layer on the tab surface, the ultrasonic energy cannot be effectively transmitted into the workpiece, and the interface is only pressed together without welding. The working face of the anvil also showed aluminum-chip indentations and a bright band.
Conclusion: the horn knurling was worn beyond its service interval, and this is the main cause of the cold welds.
Check 2: welding parameter window.
The machine parameters were retrieved: amplitude set at 80%, welding pressure 0.35MPa, welding time 0.30s, with no trigger-force monitoring. Re-measured with a force sensor, the actual applied pressure fluctuated between 0.30~0.42MPa. The high amplitude caused the tab surface material to spatter and form a ring-shaped flash, while the central zone was in fact not fully fused.
Conclusion: the parameter window was too narrow and had no closed loop.
Check 3: tab material and surface oxide layer.
Samples were taken to measure the contact resistance of the tab surface: an aluminum tab left open in the workshop for 72 hours had a contact resistance of about 3.2mΩ, while a freshly cut tab had about 0.8mΩ. The thickened natural oxide film lowers the efficiency of frictional heat generation in ultrasonic welding. On site, incoming tabs are stored for an average of 48~72 hours before going on the line.
Conclusion: the thickened oxide layer aggravates the cold welds.
Check 4: fixture positioning and clearance.
A feeler gauge was used to measure the gap at the mating face between the tab and the cap plate, giving a reading of0.10~0.15mm, while the process requires ≤0.05mm. When a gap exists, the welding pressure is first used to flatten the gap, leaving insufficient effective forging time, and the cold welds mostly appear on the side with the poorer fit.
Conclusion: flattening and positioning were inadequate.
Check 5: equipment rigidity.
A dial indicator measured the vertical play of the horn holder at 50% applied pressure, giving 0.06mm and an excessive guide bushing clearance. The play causes part of the ultrasonic energy to be lost in the vertical direction.
Conclusion: a decline in equipment rigidity is a secondary cause.
Overall judgment: horn knurling wear is the main cause, the narrow parameter window is a secondary cause, the thickened oxide layer and fixture clearance are aggravating factors, and equipment rigidity is a background factor.
Improvement 1: horn knurl dressing and life management.The horn dressing interval was changed from 'dress it when there are too many cold welds' to management by point count: dress the knurling with an oilstone once every 20,000 welds, and force replacement when the knurl-height wear exceeds 30% (i.e. below 0.056mm); run a pull test on the first article at the start of every shift to confirm. Clean aluminum chips from the anvil working face once every 8 hours.
Improvement 2: recalibrate the welding parameter window.After a parameter DOE on the tab, the settings were locked in: amplitude reduced from 80% to 65% (about 26μm), welding pressure raised to 0.42MPa with pressure closed-loop control, welding time 0.28s, and a trigger-force trigger mode added (ultrasound is emitted only when the pressure reaches 90%). Test coupons verified that the mean tensile force held steadily above 260N.
Improvement 3: control the tab oxide layer.Tabs must go on the line within 24 hours of cutting, and open workshop positions must be fitted with moisture-proof covers; add a plasma cleaning or alcohol wiping step before welding, keeping the contact resistance ≤1.0mΩ.
Improvement 4: fixture and flattening mechanism.Add a pneumatic flattening block beside the welding head to press the tab against the cap plate before welding, and recheck with a feeler gauge that the clearance is ≤0.05mm; change the locating stop block to a quick-change type and re-check it with a dial indicator after a model change.
Improvement 5: restore equipment rigidity.Replace the guide bushing of the horn holder, keeping the vertical play at 50% applied pressure within 0.02mm.
After the rework the line was tracked continuously for 2 months, with 20 pieces sampled per shift for a pull-off test; the key indicators compare as follows:
| Indicator | Before rework | After rework |
|---|---|---|
| Mean pull-off force | 228N | 262N |
| Pull-off force standard deviation | 18N | 12N |
| Process capability CPK | 0.52 | 1.72 |
| Tensile defect rate (<200N) | 5.9% | 0.4% |
| Distribution of cold-weld locations | Concentrated at the discharge-side edge, 60% | Evenly distributed |
| Horn knurl height | 0.03mm (62.5% wear) | 0.07~0.08mm (after dressing) |
| Amplitude/pressure/time | 80%/0.35MPa/0.30s | 65%/0.42MPa/0.28s |
| Tab storage time | 48~72h | ≤24h |
| Gap between the tab and the cap plate | 0.10~0.15mm | ≤0.05mm |
| Vertical play of the horn holder | 0.06mm | ≤0.02mm |
After 2 months the machine was opened up to inspect the horn: the knurling was still clear, the flash was noticeably reduced, the mean tensile force held steady in the 255~270N range, and the CPK stayed above 1.6.