This article deals with a shop-floor problem in which the burr height after slitting a positive NCM electrode reaches 15~20 μm (internal control standard ≤8 μm). It checks the five lines — upper/lower blade clearance, edge wear, axial misalignment, tension fluctuation, and dust extraction — one by one with quantified evidence, and gives the improved parameters and a before/after comparison table. Readers can use it to troubleshoot burr problems on their own slitting machines.
At a power-battery plant, positive NCM electrode is continuously slit on a slitting machine; the current collector is 15 μm aluminum foil, the total electrode thickness after single-side coating is about 120 μm, and the slit width is 112 mm. In June 2026 the shop reported: after the winding process went online, teardown of cells revealed the separator pierced by the electrode edge, and the self-short-circuit defect rate soared from 0.1% to 0.8%.
Samples were measured for burr height with a laser confocal microscope: one point every 50 mm along the slit edge, 5 rolls measured continuously; burr heights ranged from 15~22 μm with a maximum of 22 μm. The internal control standard requires burr height ≤8 μm (positive electrode) and ≤12 μm (negative electrode). The measurement is nearly 2 times the limit.
The slit-edge cross-section was examined: the edge is not a smooth cut but shows obvious roll-over and raised burrs, with coating debris flaking off. After a roll change the first roll passed, and the burrs grew steadily from the 3rd roll of continuous production. The machine is a domestic circular-blade slitter, and the upper and lower blades are cemented carbide with a cumulative cutting length of about 800,000 meters without a blade change.
Check item by item in the order "from easy to measure to hard to dismantle, from external to internal causes":
Check 1: upper/lower blade radial clearance.
The reasonable clearance for slitting metal foil is about 5%~8% of the total material thickness. With a total electrode thickness of 120 μm the reasonable clearance should be 6~10 μm. Using a feeler gauge at the middle of the blade shaft, the measured upper/lower blade clearance is35 μm, 4 times the reasonable value. When the clearance is too large the material is not sheared but torn, forming elongated burrs.
Conclusion: the blade clearance is out of tolerance and is the main cause of the burrs.
Check 2: blade edge sharpness.
Removing the upper blade and measuring the edge radius under a toolmaker's microscope. A new blade has an edge radius R≤3 μm; this blade measuredR=16 μm, so the edge is dulled. After a cumulative cut of 800,000 meters the cemented carbide blade's edge rounds off under abrasion by coating particles, shearing becomes squeezing, and the burrs inevitably grow.
Conclusion: the blade has served beyond its life.
Check 3: upper/lower blade axial misalignment.
Indicating the axial misalignment of the upper and lower blades at the meshing point, measured0.05 mm, with the machine manual allowing ≤0.01 mm. Axial misalignment misaligns the upper/lower blade contact line, one edge cannot press fully, and one-sided burrs form.
Conclusion: the blade set was not fine-adjusted after re-assembly.
Check 4: slitting tension fluctuation.
With tension meters attached at the unwinding and rewinding ends: the set tension is 80 N but the actual value fluctuates between 60~110 N, a fluctuation range of±25%. With large tension fluctuation the electrode makes tiny shifts under the blade, and the cut face is uneven.
Conclusion: the tension closed-loop control is inadequate.
Check 5: dust extraction effectiveness.
The measured air velocity at the dust hood near the blade edge is 8 m/s, while the manual requires ≥15 m/s. Debris accumulates at the blade edge and is pressed back into the electrode edge by the blades, forming secondary burrs.
Conclusion: the dust extraction airflow is insufficient.
Overall assessment: excessive blade clearance and edge dulling are the main causes, axial misalignment is a secondary cause, and tension fluctuation and insufficient dust extraction are aggravating factors.
Improvement 1: re-adjust the upper/lower blade radial clearance.
Stop the machine and clean residual adhesive and coating powder from the blade faces, then re-set the blades. Take the target clearance at 6% of the total thickness: 120 μm × 6% = 7.2 μm, controlled at6~8 μm. Use a 0.005 mm feeler gauge to measure at three points around the full meshing face, with a deviation ≤1 μm.
Improvement 2: replace with new blades and set up life management.
Replace both upper and lower blades with new cemented carbide circular blades. The specified cutting life is300,000 metersthey must be removed for regrinding, no longer following the passive mode of "change them once the burrs get big". After the new blades are installed, run them in for 500 m, sample and confirm the burrs are ≤5 μm, then start volume production.
Improvement 3: correct the upper/lower blade axial misalignment.
Re-indicate and adjust the blade holders, keeping the axial misalignment within0.005 mm(twice as tight as the manual's allowance). After adjustment, turn the blades by hand through one revolution and check that the meshing line is continuous with no breaks.
Improvement 4: upgrade the tension closed loop.
Change the open-loop magnetic-particle brake to a servo tension closed loop; the unwinding tension is set at 80 N with a control accuracy of±5%(i.e. 76~84 N). Add floating-roller position feedback at the slitting entry, limiting the floating-roller travel to ±5 mm.
Improvement 5: increase the dust extraction airflow.
Clean accumulated dust from the extraction duct, shrink the dust hood opening and bring it close to the blade edge (distance ≤5 mm); the measured air velocity rises to18 m/s. Check the suction-port vacuum gauge at the start of each shift.
After the rework it was tracked continuously for 3 months, sampling the burr height on every roll; the key indicators compare as follows:
| Indicator | Before rework | After rework |
|---|---|---|
| Upper/lower blade radial clearance | 35 μm | 7 μm |
| Edge radius R | 16 μm | 3 μm (new blade) |
| Upper/lower blade axial misalignment | 0.05 mm | 0.005 mm |
| Slitting tension fluctuation | ±25%(60~110 N) | ±5%(76~84 N) |
| Dust extraction air velocity at the blade edge | 8 m/s | 18 m/s |
| Burr height | 15~22 μm | 4~6 μm |
| Burr defect rate | 8.5% | 0.3% |
| Winding self-short-circuit defect rate | 0.8% | 0.05% |
| Blade replacement interval | Reactive blade change after 800,000 meters | Scheduled replacement every 300,000 meters |
3 months later the blades were removed for inspection: the edges are still sharp, the blade faces show no obvious indentations, and the burr height holds steady in the 4~6 μm range.