Rotating parts must have a guard. Guard clearance ≤10mm. Safety distances follow ISO 13857. Emergency stop buttons are red mushroom-head type.
The installation distance of a safety light curtain must be calculated (S=K×T+C).
Protective earthing resistance of equipment ≤4Ω. Lightning protection earthing ≤10Ω. The earthing conductor must be at least 1/2 of the phase conductor cross-section. In a TN-S system the PE line must never be disconnected.
Earthing terminals must be secured against loosening and the earthing resistance must be tested periodically.
Check guards before starting. Never put hands into the danger zone while running. After stopping, cut off the power and hang a warning tag.
New staff must complete safety training before being allowed to work on the equipment.