A reinforcing structure for castings and welded parts. Design points:
① Rib thickness is 0.6~0.8 times the adjacent wall thickness
② Height ≤5 times the wall thickness
③ Avoid cross-shaped intersections
④ Place on the compression side
⑤ Provide vent holes (for castings)
A pipe and vessel connection element. Design points:
① Number and diameter of bolt holes according to the pressure class
② Sealing face Ra≤1.6μm
③ Flange thickness calculated from the pressure
④ Select a standard flange (GB/T 9112)
The foundation for equipment installation. Design points:
① Flatness ≤0.05/500mm
② Provide anchor bolt holes
③ Place weight-relief grooves in non-load-bearing areas
④ Allow for forklift handling
A safety protection structure. Design points:
① Safety distances per ISO 13857
② Ventilation opening area ≥10% of the surface area
③ Provide an inspection window
④ Hinges for convenient opening and closing
An access door for equipment maintenance. Design points:
① Hinges of sufficient strength
② Door lock preventing accidental opening
③ Seal strip for water and dust protection
④ Limit safety switch
A human-machine operating part. Design points:
① Reasonable load direction
② Anti-slip texture
③ No sharp edges
④ Spacing suitable for gripping
A wheel for moving equipment. Design points:
① Load capacity = 1.5 times the total equipment weight
② Swivel casters at the front, fixed casters at the rear
③ Braking function provided
④ Rubber wheels for vibration damping
Equipment fixing. Design points:
① Anchor bolts M16~M30
② Fixed by secondary grouting
③ Leave anchor holes in slots in the base
④ Use shims to adjust levelling
A heat dissipation structure. Design points:
① Fin spacing ≥ half the fin height
② Perpendicular to the heat flow direction
③ Aluminium dissipates heat better than steel
④ For natural convection, orient the fins vertically
Static sealing. Design points:
① Resistant to corrosion by the medium
② Working temperature within range
③ Compression ratio 15~25%
④ Contact surface Ra≤3.2μm
Protection for cables and hoses. Design points:
① Inner height > maximum cable diameter × 1.2
② Bending radius ≥10 times the maximum cable outer diameter
③ Fix both ends during installation
④ Choose bridge type (dust proof) or enclosed type
For viewing inside the equipment. Design points:
① Toughened glass ≥5mm
② Sealing ring for oil and water resistance
③ Provide a protective grille
④ Sensible installation position
A vibration reduction element. Design points:
① Natural frequency must avoid the equipment operating frequency
② Compression ≤15% of the thickness
③ Use rubber or spring dampers
④ Use active vibration isolation for precision equipment
Related quick references: Tolerances & FitsSurface RoughnessMaterial Heat TreatmentCast Part DesignGeometrical TolerancesDimension ChainsWelded StructuresSheet Metal StructuresShafting DesignSeal DesignMaterial SelectionHeat TreatmentDatum ReferencingTolerance Principles