Carbon content: 0.42%~0.50% (medium-carbon steel)
Performance characteristics:
• Balanced strength and toughness, excellent overall mechanical properties
• Hardness after quenching HRC48~55 (water quench)
• Tensile strength after quenching and tempering σb≈650~800MPa
• Annealed HB≤197, normalized HB170~217
• Moderate hardenability (critical diameter about 10~15mm)
Applications: general machine parts such as transmission shafts, gear shafts, connecting rods and bolts
Case: a φ50 transmission shaft made of 45 steel, quenched and tempered to HB220~250
Carbon content: 0.37%~0.44%
Alloying element: Cr 0.80%~1.10%
Performance characteristics:
• Better hardenability than 45 steel (critical diameter about 25~30mm)
• Hardness after quenching HRC50~55
• Tensile strength after quenching and tempering σb≈800~1000MPa (about 30% higher than 45 steel)
Compared with 45 steel: at the same hardness, 40Cr has about 50% higher yield strength
Costs about twice as much as 45 steel; suitable for critical parts of medium section
Applications: critical shafts, gears, connecting-rod bolts
Carbon content: 0.95%~1.05% (high-carbon bearing steel)
Alloying element: Cr 1.30%~1.65%
Performance characteristics:
• Hardness after quenching HRC60~66
• Extremely high contact fatigue strength
• Excellent wear resistance
• Good dimensional stability after heat treatment
Heat treatment process: spheroidizing anneal → quench at 830~860℃ → oil cool → low-temperature temper at 150~170℃
Applications: rolling-bearing rings, rolling elements, precision gauges
Case: 6205 bearing ring, GCr15 quenched to HRC61~65
Carbon content: 0.62%~0.70% (spring steel)
Alloying element: Mn 0.90%~1.20%
Performance characteristics:
• Fairly good hardenability
• Hardness after quenching HRC55~60
• High elastic limit
• Economical price
• Prone to quenching cracks (oil quenching recommended)
Heat treatment: quench at 790~830℃ → oil cool → temper at 380~480℃
Applications: springs, spring clips, spring washers, saw blades, agricultural machinery parts
Tensile strength: σb≥250MPa
Composition: C 3.0~3.3%, Si 1.5~2.0%, Mn 0.6~1.0%
Hardness: HB170~240
Characteristics:
• Good casting fluidity, can cast complex parts
• Excellent machinability
• Better damping than steel (suitable for machine-tool beds)
• Low cost
Applications: machine-tool beds, columns, gearbox housings, bearing housings, engine blocks
Case: the bed of a C6140 lathe is cast in HT250
Tensile strength: σb≥500MPa
Yield strength: σs≥320MPa
Elongation: δ≥7%
Hardness: HB180~230
Microstructure: ferritic + pearlitic ductile iron
Characteristics: good overall mechanical properties, far tougher than gray iron, can replace cast steel
Applications: automotive crankshafts, connecting rods, gearbox housings, valves, agricultural machinery parts
Case: a passenger-car crankshaft made of QT500, 15% lighter than a steel one
Carbon content: ≤0.22% (low-carbon steel)
Yield strength: ≥235MPa (varies with thickness)
Characteristics:
• Excellent weldability
• Lowest cost
• Cannot be strengthened by heat treatment
• Relatively low strength but good toughness
Applications: welded structures, equipment bases, frames, platforms, and sections such as angle steel/channel steel/I-beams
Case: a welded equipment base made of Q235, with no heat treatment required for the welds
Carbon content: 0.18%~0.24% (low-carbon alloy steel)
Alloying element: Cr 0.70%~1.00%
Use: carburized parts
Heat treatment: carburize → quench → low-temperature temper
• Case depth 0.8~1.2mm
• Surface hardness HRC58~63
• Core hardness HRC35~45
Characteristics: hard, wear-resistant surface with a tough, impact-resistant core
Applications: gears, small shafts, piston pins, rollers, cams, shift forks
Carbon content: 0.95%~1.04% (carbon tool steel)
Heat treatment: quench at 760~780℃ → water cool → low-temperature temper at 160~200℃
Working hardness: HRC62~64
Characteristics:
• High hardness, good wear resistance
• Poor hardenability (requires water quenching)
• Prone to quenching cracks (heating temperature must be controlled)
Applications: hand tools (files, taps, dies), punches, measuring tools (calipers)
Carbon content: 0.70%~0.80%
Alloying elements: W 17.5%~19.0%, Cr 3.8%~4.4%, V 1.0%~1.4%
Key property: red hardness
Still holds HRC60 or above at 600℃, allowing cutting speeds up to 40~60m/min
Heat treatment: quench at 1260~1290℃ → oil cool or salt bath → temper at 560℃, 3 times
Working hardness: HRC63~66
Applications: high-speed cutting tools such as high-speed turning tools, milling cutters, drills, hobs and broaches
Definition: the ratio of circular pitch to π, in mm
Standard module series (GB/T 1357):
First series: 1, 1.25, 1.5, 2, 2.5, 3, 4, 5, 6, 8, 10, 12, 16, 20, 25, 32, 40, 50
Second series: 1.125, 1.375, 1.75, 2.25, 2.75, 3.5, 4.5, 5.5, 7, 9, 11, 14, 18, 22, 28, 36, 45
Selection rule: prefer the first series
Case: a gear with m=3mm and z=30 teeth has a pitch-circle diameter d=mz=90mm
Standard pressure angle: α=20° (the vast majority of gears)
Other pressure angles:
• 14.5°: old standard, rarely used now
• 22.5°: high-strength gears
• 25°: heavy-duty gears
Effect of pressure angle:
Larger → thicker tooth root, higher strength → more sensitive to center distance, noisier
Smaller → thinner tooth root, lower strength → smoother transmission, quieter
Standard value: ha*=1.0
Formulas:
• Addendum ha = ha* × m
• Whole depth h = ha + hf = 2.25m (standard gears)
Case: for a standard gear with m=3mm, addendum ha=1.0×3=3mm and whole depth h=2.25×3=6.75mm
Stub-tooth system: ha*=0.8, used where contact ratio requirements are not strict
Standard value: c*=0.25 (clearance coefficient)
Formulas:
• Dedendum hf = (ha*+c*)×m = 1.25m
Function: ensure that when a pair of gears meshes there is a gap between the addendum of one gear and the dedendum of the other, avoiding interference while holding lubricating oil
Case: for a standard gear with m=3mm, dedendum hf=1.25×3=3.75mm and clearance=0.25×3=0.75mm
Four key characteristics:
① Center-distance separability: the transmission ratio stays constant even if the center distance is off (the most important characteristic)
② Constant transmission ratio: the involute profile satisfies the fundamental law of gearing
③ Straight line of action: the force direction stays constant and load carrying is smooth
④ Good machinability: can be cut with a standard hob
Compared with cycloidal gears: cycloidal gears are not center-distance separable and are complex to manufacture
Case: a ±0.1mm center-distance deviation in a gearbox gear does not affect the transmission ratio
Five main functions:
① Avoid undercutting: use a positive shift when the tooth count is <17
② Match the center distance: adjust by shifting when the standard center distance is not suitable
③ Improve tooth-root strength: a positive shift thickens the tooth root and raises strength
④ Improve tooth-flank contact strength
⑤ Repair worn gears: cut away the worn layer with a negative shift and pair it with a new positively shifted gear
Positive shift → thicker tooth root, pointed tooth tip, higher strength
Negative shift → thinner tooth root, wider tooth tip, lower strength
Case: a small gear with z=14 uses a positive shift x=+0.3 to avoid undercutting
Common range: β=8°~20°
Recommended values:
• Single-stage reduction: β=8°~15°
• High-speed gears: β=10°~20°
• Herringbone gears: β=25°~35°
• Automotive transmissions: β=25°~35°
The larger the helix angle → the greater the contact ratio → the smoother the transmission → the greater the axial force
The smaller the helix angle → the smaller the axial force → the smaller the contact ratio
Case: helical gears in an ordinary reducer use β=12°
Common values: z1=1, 2, 4, 6
Relation between the number of starts and the transmission ratio and efficiency:
• z1=1: i=40~80, efficiency η≈50~65%, self-locking, low speed
• z1=2: i=20~40, efficiency η≈65~75%, most common
• z1=4: i=10~20, efficiency η≈75~85%, high speed
• z1=6: i=5~10, efficiency η≈85~90%, high speed and light load
Case: hoisting worms use z1=1 (self-locking), machine-tool indexing worms z1=1~2
Accuracy grades (ISO 3408): C0 (highest) → C1 → C2 → C3 → C5 → C7 → C10
Cumulative error per 300mm:
• C0: ±3.5μm (jig borers, measuring machines)
• C1:±5μm
• C3: ±12μm (machining centers, precision grinders)
• C5: ±23μm (CNC lathes, milling machines)
• C7: ±50μm (ordinary automation equipment)
• C10: ±210μm (conveyor positioning)
Selection: the higher the accuracy, the higher the price; choose just enough to meet the application requirements
Definition: basic static load rating C0 / maximum static load
Recommended values:
• General machinery: fs≥1.0~1.5
• With impact and vibration: fs≥2.0~3.0
• High-precision positioning: fs≥2.5
• Cantilever mounting: fs≥3.0
Selection steps: ① Calculate the maximum load → ② Determine the required C0=Pmax×fs → ③ Select the guide model
Common materials and their properties:
• Polyurethane PU: good elasticity, wear-resistant, oil-resistant, working temperature -30~80℃, most commonly used
• Nylon PA: high strength, wear-resistant, resistant to chemical corrosion
• Rubber NR: good vibration damping, low cost, not oil-resistant
• Hytrel: heat-resistant from -40~150℃, high elasticity and high strength
Suitable coupling types: PU → jaw couplings/star couplings, rubber → tire couplings, nylon → pin couplings
Selection: high-precision servo → PU/Hytrel, general transmission → rubber/nylon
NBR (nitrile rubber): -40~120℃
Characteristics:
• Excellent resistance to mineral oil and hydraulic oil
• Good wear resistance
• Economical price
• Not resistant to ozone or ultraviolet light
Applications: hydraulic oil seals, O-rings, oil lines, gaskets
Not suitable for: strong acid/alkali environments, ketone solvents, >120℃ high-temperature environments
FKM (fluoroelastomer): -25~250℃
Characteristics:
• Outstanding high-temperature performance
• Excellent chemical resistance (acids/alkalis/solvents)
• Excellent oil resistance
• Relatively expensive (5~10× NBR)
Applications: high-temperature hydraulic systems, engine oil seals, chemical-media seals, vacuum systems
Case: an engine crankshaft oil seal made of FKM, withstanding working temperatures up to 200℃
PTFE:-200~260℃
Characteristics:
• Extremely low friction coefficient (0.04)
• Resistant to virtually all chemical media
• Non-stick
• Poor elasticity (requires a spring for compensation)
Applications: aggressive-media seals, high-temperature service, static seals in the food/pharmaceutical industry
Forms: PTFE gaskets, PTFE lip seals with spring, combined seal rings
Recommended fill amount:
• Low-speed bearings: fill 1/2~2/3
• Medium- and high-speed bearings: fill 1/3~1/2
• High-speed precision bearings: fill less than 1/3
• Vertical mounting: reduce the fill amount
Hazards of overfilling: a sharp temperature rise (the most common cause of bearing overheating), grease leakage, increased churning resistance
Case: SKF6204 bearings in a high-speed motor, filled with about 10g (1/3 of the cavity)
Normal range: -30~120℃ (general deep-groove ball/cylindrical roller bearings)
Temperature vs. life: for every 10℃ rise, grease life is shortened by about 50%
• Below 80℃: optimum working range
• 80~100℃: special grease required
• 100~150℃: high-temperature bearing steel + high-temperature grease required
Bearing-housing temperature rise: up to 45℃ above ambient is normal; stop and inspect if it exceeds 60℃
Temperature grades:
• Standard bearings: -30~120℃
• High-temperature class A: -30~200℃
• High-temperature class B: -30~250℃
• Ultra-high temperature: -30~350℃
Materials: Cr4Mo4V withstands 350℃, 440C stainless steel 250℃, Si3N4 ceramic 1000℃
Lubrication: use high-temperature grease at 150~250℃, solid lubricants (MoS2/graphite) at >250℃
Recommended intervals:
• New gearbox: first oil change at 300~500h
• Normal conditions: change oil every 3000~5000h
• High temperature and dusty: change oil every 1000~2000h
• Continuous operation: change oil every 6 months
Oil-change criteria: viscosity change >±15%, acid value >1.0mgKOH/g, water content >0.2%
Recommended intervals:
• Normal conditions: every 2000~4000h or annually
• Severe conditions: every 1000~2000h
• First oil change: after 500h of operation
Criteria: viscosity change ±15%, water content >0.1%, acid value >0.3mgKOH/g, contamination level >NAS class 10
Case: an injection-molding machine hydraulic system running 24h continuously → change oil every 2000h
Four main functions:
① Cooling: carries away cutting heat (water-based is best)
② Lubrication: reduces tool-workpiece friction (oil-based is best)
③ Cleaning: flushes away chips and prevents scratching the machined surface
④ Rust prevention: protects the workpiece and machine-tool surfaces
Types:
• Emulsion: water + oil, balancing cooling and lubrication, most commonly used
• Cutting oil: pure mineral oil, mainly for lubrication
• Aqueous solution: best cooling, poor lubrication
Selection: rough machining → emulsion (cooling), finish machining → cutting oil (lubrication)
Recommended concentrations:
• General turning and milling: 5~10%
• Grinding: 3~5%
• Drilling/tapping: 10~15%
• Deep-hole drilling: 15~20%
Too high a concentration → higher cost and poorer cooling
Too low a concentration → insufficient lubrication, rapid tool wear, prone to rust
Daily maintenance: check the concentration with a refractometer every day, top up with concentrate if low, and replace the whole batch if it has deteriorated
Standard unit: m/min (meters per minute)
Conversion formula: v = π×d×n/1000 (d in mm, n in r/min)
Typical values:
• Turning 45 steel: rough turning 60~100m/min, finish turning 100~150m/min
• Turning aluminum alloy: 200~600m/min
• 304 stainless steel: 60~120m/min
• Turning cast iron: 50~100m/min
Case: a φ80mm workpiece at n=400r/min, v=3.14×80×400/1000=100.5m/min
Standard unit: mm/r (feed per revolution)
Other forms:
• Feed per tooth fz: mm/z (used in milling)
• Feed per minute vf: mm/min
• Conversion: vf=fz×z×n
Typical values:
• Rough turning: 0.3~1.0mm/r
• Finish turning: 0.05~0.2mm/r
• Milling: 0.05~0.3mm/z
• Drilling: 0.05~0.5mm/r
Standard Ra value series: 50, 25, 12.5, 6.3, 3.2, 1.6, 0.8, 0.4, 0.2, 0.1, 0.05μm
Ra values for machining methods:
• Rough turning/rough milling: Ra12.5~6.3
• Finish turning/finish milling: Ra3.2~1.6
• Rough grinding: Ra1.6~0.8
• Finish grinding: Ra0.8~0.4
• Lapping/honing: Ra0.2~0.05
Application guidance: Ra6.3 for non-mating surfaces, Ra3.2 for general fits, Ra1.6 for fairly precise fits, Ra0.8 for bearing mating surfaces
This is basic knowledge that mechanical engineers should master.
For specific values and their meaning, refer to the relevant chapters of the Mechanical Design Handbook or look them up in the other modules of this software.
This is basic knowledge that mechanical engineers should master.
For specific values and their meaning, refer to the relevant chapters of the Mechanical Design Handbook or look them up in the other modules of this software.
Standard scale series:
• Full size: 1:1
• Reduction: 1:2, 1:2.5, 1:5, 1:10, 1:20, 1:50, 1:100, 1:200
• Enlargement: 2:1, 2.5:1, 5:1, 10:1
Selection rules:
• Prefer 1:1 for a direct, true representation
• Use reduction scales for large parts (1:2, 1:5)
• Use enlargement scales for small complex parts (2:1, 5:1)
• Use the same scale for all views of a part
Standard position: lower-right corner of the drawing (GB/T 14689)
Main contents of the title block: part name, drawing number, material grade, scale, weight, signatures for design/drafting/review, company name, date
Layout: A4 portrait → the bottom edge of the title block coincides with the lower border
A3/A2/A1 landscape → the title block is in the lower-right corner
The title block is the drawing's identity card and must be filled in completely
Standard format (filled in from bottom to top):
Item No.│Code│Name│Qty│Material│Unit Weight│Total Weight│Remarks
Filling rules:
• Item numbers start at 1 and match the leader-line numbers on the views
• The code is the part drawing number or the standard-part code
• Write the material grade
• Remarks cover heat treatment/surface treatment, etc.
Position: above the title block, arranged from bottom to top (so items can be added easily)
Standard drawing method (GB/T 1182):
┌──┬────┬──┐
│Symbol│Tolerance Value│Datum│
└──┴────┴──┘
Number of compartments:
• Form tolerance: 2 compartments (symbol + tolerance value)
• Position tolerance: 3 compartments (symbol + tolerance value + datum letter)
Common symbols:
— Straightness, ⏥ Flatness, ○ Roundness, ⏪ Cylindricity
∥ Parallelism, ⟂ Perpendicularity, ◎ Coaxiality, ⊕ Position, ↗ Circular runout
Case: coaxiality callout ┌──┬────┬──┐
│ ◎ │φ0.02 │ A │
└──┴────┴──┘
Letter (A, B, C...)
│
○
│
──┼── thick short dash
│
Callout rules:
• The datum symbol uses a thick short dash + small circle + capital letter
• The letter must not be upside down
• The same datum uses the same letter in different views
• Do not use I, O, Q (easily confused)
Case: common datum A-B for the bearing seats at both ends: the frame reads φ0.02 A-B
Symbol forms:
✓ — obtained by any method
✓✓ — material removal required to obtain it
✓✗ — obtained without material removal
The Ra value is written above the symbol, e.g.: √ Ra1.6
Rule: the tip of the symbol must point from outside the material toward the machined surface
Case: √ Ra3.2 → finish-turned surface, √ Ra0.8 → ground surface
Standard composition: reference line + arrow line + basic weld symbol + supplementary symbol + dimensions
Position rules:
• Symbol above the reference line → weld on the arrow side
• Symbol below the reference line → weld on the other side
Common symbols: ││ butt weld, ∧ fillet weld, ∨ V-groove
Case: a fillet weld with a 5mm leg, called out as k5 plus the all-around weld symbol ○
Complete callout format: thread code - nominal diameter × pitch, hand - tolerance class, length of engagement
Common examples:
• M10×1.5-6g: standard coarse thread
• M16×1.5-6H: fine thread (pitch 1.5mm)
• M20×1.5-LH: left-hand thread
• Tr40×7-7H: trapezoidal thread
Coarse threads omit the pitch; fine threads must state the pitch
Parameter table contents (upper-right corner of the drawing):
Module m=___, number of teeth z=___, pressure angle α=20°
Addendum coefficient ha*=1.0, profile shift coefficient x=___
Accuracy grade ___ GB/T 10095
Base tangent length Wk=___mm, number of teeth spanned k=___
Case: m=3, z=30, α=20°, x=0, accuracy 8GJ GB/T 10095
Helical compression spring parameters:
• Wire diameter d, outer diameter D/mean diameter D2
• Number of active coils n, total number of coils n1
• Free length H0, solid height Hb
• Hand (left/right), developed length L
Must be called out: heat-treatment requirements, surface treatment (bluing/phosphating/shot peening)
Standard: GB/T 145
Callout format: center hole, type, nominal diameter d/D
Types:
Type A: without protecting chamfer (most commonly used)
Type B: with 120° protecting chamfer (shafts that keep the center hole)
Type C: with thread (shafts that will later be drawn/extracted)
Case: center holes at both ends of a drive shaft → center hole B2.5/7 GB/T 145
Types and callouts:
① Flat-bottom counterbore: ⏆ counterbore φ12, depth 6
② Countersink: ⏢ countersink φ13.5×90°
③ Countersunk hole: countersunk hole φ20×90°
Note: a counterbore must specify diameter + depth or angle
Case: M8 bolts on a mounting plate → ⏆ counterbore φ14, depth 8
Callout: taper 1:n
Meaning: taper=(D-d)/L = 1:n (D large end, d small end, L length)
Common tapers:
• 1:10 — common locating taper surface
• 1:50 — machine-tool spindle taper bore
• 7:24 — milling machine spindle (BT/ISO standard)
• Morse taper — drill/center taper shanks (No. 0~6)
Callout: slope 1:n
Meaning: slope=tanθ = h/L = 1:n (θ is the angle of inclination)
Common slopes:
• 1:5 — fixture wedge
• 1:10 — wedge block
• 1:20 — guideway wedge
Difference from taper: slope is height/length (one direction), taper is diameter difference/length (both directions)
Definition: the time for one complete cycle of the PLC reading inputs → executing the program → updating outputs
Typical values:
• Small PLCs: 1~10ms
• Medium PLCs: 5~20ms
• Large PLCs: 10~50ms
Influencing factors: number of program steps, communication tasks, instruction types
Impact: a long scan cycle → slow response; high-speed signals require a high-speed counter module
Case: a detection signal must respond within 10ms → PLC scan cycle ≤5ms
Definition: electronic gear ratio = encoder feedback pulses / command pulses
Purpose:
• Reconcile the PLC pulse output frequency with the motor resolution
• Change the pulse equivalent without replacing mechanical gears
Example calculation: encoder 2500 lines, screw lead 10mm, requiring 1 pulse = 0.01mm
Pulses per revolution = 10/0.01 = 1000 pulses/rev
Electronic gear ratio = 2500/1000 = 2.5 = 5/2
Setting: set the numerator to 5 and the denominator to 2
Definition: the curve of a VFD's output voltage versus frequency
Basic principle:
• Constant-torque region: V/f = constant (0~rated frequency)
• Constant-power region: above rated frequency, the voltage stays at rated value
Significance: maintains constant flux → keeps the motor output torque constant
Common modes:
• Linear V/F: general purpose
• Quadratic V/F: energy saving for fans/pumps
• Sensorless vector: a high-performance alternative to V/F
Case: a fan using quadratic V/F → lower voltage at low frequency → over 30% energy savings
Definition: subdividing one full step of a stepper motor into multiple microsteps
Common microstep settings:
• Full step (1 microstep): 1.8°/step
• 2 microsteps (half step): 0.9°/step
• 4 microsteps: 0.45°/step
• 8 microsteps: 0.225°/step
• 16 microsteps: 0.1125°/step
• 32 microsteps: 0.05625°/step
The higher the microstep setting → the higher the resolution → the less vibration → the greater the torque loss at high speed
Beyond 64 microsteps the improvement is not significant
Recommendation: use 8~16 microsteps for general automation equipment
Incremental: resolution = number of lines (pulses per revolution)
Absolute: resolution = number of bits (2^n positions per revolution)
Selection steps:
① Determine the required accuracy (e.g., positioning ±0.01mm)
② Calculate the travel per screw revolution (e.g., lead 10mm)
③ Required lines = 10/0.01 = 1000 lines
Reference values: 1000~2500 lines for general positioning, 5000~8000 lines for precision positioning
Case: screw lead 20mm requiring 0.005mm/pulse → encoder with 4000 lines
Practical engineering values:
• Slowly varying temperature/pressure signals: 0.1~1 second
• Flow/speed signals: 10~100ms
• Servo position loop: 0.5~2ms
• Current loop: 0.05~0.2ms
• Vibration signals: 1~10kHz sampling
Principles:
Too short a period → large data volume, heavy CPU load
Too long a period → missed signals, slow response
Case: hydraulic pressure monitoring → a 100ms sampling period is sufficient
Three methods:
① Trial and error: first set only P, increase it to sustained oscillation, then set P to 50~60%; add I to eliminate steady-state error (I = 1~2× the oscillation period); add D to improve the response
② Ziegler-Nichols method: with P alone, bring it to the critical oscillation → record Ku and Tu → P=0.6Ku, I=0.5Tu, D=0.125Tu
③ Auto-tuning: one-key automatic tuning on the drive, fast and practical
Case: servo position loop → P=30, I=50ms, D=10ms
Principle: cutoff frequency ≥ useful signal frequency and ≤ noise frequency/3
Practical engineering values:
• Mechanical vibration filtering: 10~100Hz
• Electrical noise filtering: 1~10kHz
• Sensor smoothing: 5~50Hz
Case: a pressure sensor has 20Hz pump pulsation noise and a 2Hz useful signal → choose a 5Hz cutoff frequency
Common values:
• RS232:9600、19200、38400、115200
• RS485:9600~115200
• CAN bus: 125k, 250k, 500k, 1M
Distance vs. speed: 1200m → 9600bps, 100m → 115200bps
Selection: sensor instruments → RS485 at 9600bps, servos/VFDs → 115200bps
Typical values:
• Photoelectric/proximity switches: 0.5~5ms
• Pressure sensors: 1~10ms
• Temperature sensors: 100~500ms (thermocouples)
• Laser sensors: 0.1~1ms
• Encoders: 0.02~0.1ms
Principle: response time < signal duration/5
Case: detecting a 10mm zone at 1m/s → signal lasts 10ms → response time must be <2ms
Three types:
① Through-beam: 5~30m, long range, requires separate emitter and receiver
② Retro-reflective: 0.1~10m, requires a reflector
③ Diffuse-reflective: 0.01~2m, strongly affected by object color
Color influence: white 100%, black only 30~50%
Case: long-range detection on a conveyor line → through-beam at 10m
Standard sensing distances:
• φ6.5 cylindrical: 1~2mm
• φ12 cylindrical: 2~4mm
• φ18 cylindrical: 5~8mm
• φ30 cylindrical: 10~20mm
Detects metals only; ferromagnetic metals give the longest sensing distance
Material reduction factors: steel ×1.0, stainless steel ×0.6~0.9, copper ×0.3~0.45, aluminum ×0.35~0.50
Sensing range: 1~25mm (depending on model)
Characteristics:
• Detects all materials (metals + non-metals)
• Can detect liquid levels (through the container wall)
• Strongly affected by humidity and temperature
Applications: plastic hopper level detection, glass detection, liquid-level detection
Note: keep the switch away from non-target objects during installation to avoid false triggering
Principle: emit an ultrasonic pulse → receive the reflected wave → measure the time difference → calculate the distance
Characteristics:
• Unaffected by object color or transparency
• Can detect transparent objects (glass/plastic)
• Affected by temperature/airflow
• Has a blind zone (cannot detect at close range)
Sensing distance: 0.1~8m (depending on model)
Applications: level measurement, transparent bottle detection, presence detection of people/objects
Laser classes (IEC 60825):
• Class 1: safe, safe for direct viewing by the eye
• Class 1M: safe, but hazardous when viewed with optical instruments
• Class 2: visible light, <1mW, the blink reflex provides protection
• Class 2M: similar to class 2, hazardous when viewed with optical instruments
• Class 3R: <5mW, hazardous if viewed directly
• Class 3B: >5mW, hazardous both directly and in reflection
• Class 4: high power, can cause burns/fire
Industrial sensors mostly use Class 1 or Class 2
Principle: light-emitting element → transmission through the fiber → emission at the sensing end → reception of reflected or through-beam light → the amplifier processes the signal
Characteristics:
• Fiber heads can be made extremely small (below φ3mm)
• Withstands high temperature/high humidity/strong magnetic fields
• The amplifier is separate from the sensing head
• Detects tiny objects (0.01mm)
Applications: detection of tiny parts, narrow gaps, and high-temperature environments
Principle: emit RGB tricolor light → receive the reflected light → compare color differences → output a signal
Characteristics:
• Can distinguish different colors (color marks)
• Fast detection (microsecond level)
• Requires color calibration
Applications: color-mark registration on packaging bags, label detection, print recognition, date verification on food packaging
Common output types:
• Analog: 4~20mA (most common), 0~10V, 0~5V
• Digital: RS485 Modbus, IO-Link, CANopen
Features of 4~20mA:
• 4mA corresponds to zero (allows broken-wire detection)
• 20mA corresponds to full scale
• Strong noise immunity
• Supports long-distance transmission
Selection: 4~20mA output is the first choice in industrial environments
Principle: range = maximum load × safety factor
Safety factors:
• Static weighing: 1.0~1.5×
• Dynamic weighing: 1.5~3×
• Impact loads: 3~5×
Common ranges: 5kg, 10kg, 20kg, 50kg, 100kg, 200kg, 500kg, 1t, 2t, 5t
Case: a hopper with a total weight of 200kg (including material) and no impact → choose a 300kg-range sensor
Main types:
① Turbine flowmeter: high accuracy, suitable for clean liquids
② Electromagnetic flowmeter: conductive liquids, no pressure loss
③ Vortex flowmeter: suitable for both gases and steam
④ Ultrasonic flowmeter: non-contact, large pipe diameters
⑤ Rotameter: small flows, visual indication
⑥ Mass flowmeter (Coriolis): high accuracy, measures mass directly
⑦ Thermal flowmeter: gas flow measurement
National standard (GB/T 3805):
• 42V: environments with electric shock hazard
• 36V: general safety voltage (machine-tool lighting)
• 24V: portable lighting, control circuits
• 12V: damp environments, where the human body may make contact
• 6V: underwater equipment, medical
Most commonly used: 24V DC (PLC control circuits, sensor power supply)
Case: machine-tool work lamps use a 36V safety voltage
IP65 — dust-tight + protected against water jets
First digit 6: dust-tight (complete protection against dust)
Second digit 5: protected against water jets (water jetted in any direction has no harmful effect)
Applications: outdoor equipment, damp environments, food machinery
Case: terminal boxes of outdoor motors require IP65
IP67 — dust-tight + protected against short-term immersion
First digit 6: dust-tight
Second digit 7: short-term immersion (1m depth for 30 minutes)
Applications: washdown equipment, long-term outdoor exposure
Note: IP67 does not mean continuous underwater operation (that is IP68)
Case: sensors on a car wash line require IP67
IP54 — dust-protected + protected against splashing water
First digit 5: dust-protected (some dust can enter, not completely sealed)
Second digit 4: protected against splashing water (splashing from any direction has no harmful effect)
Applications: general-purpose motors, clean indoor environments
Case: ordinary fan motors and pump motors are generally IP54
Reference current-carrying capacity of copper-core cables (30℃ ambient):
• 1.5mm²:16A
• 2.5mm²:25A
• 4mm²:32A
• 6mm²:42A
• 10mm²:60A
• 16mm²:80A
• 25mm²:110A
• 35mm²:140A
Derating: apply a factor of 0.7~0.9 for elevated temperature, multiple cables side by side, and conduit installation
Selection: rated current × 1.25 ≤ cable current-carrying capacity
Practical safe current-carrying values for copper conductors:
Cross-section mm² = rated current I/4~5 (i.e., 4~5A per mm²)
Quick reference:
• 0.5mm² → 3A (signal lines)
• 0.75mm² → 6A (sensor lines)
• 1.5mm² → 16A (general electrical)
• 2.5mm² → 25A (socket circuits)
• 4mm² → 32A (high power)
• 6mm² → 42A (main circuits)
The current-carrying capacity of aluminum wire is about 75% that of copper
① Rated voltage ≥ line voltage
② Rated current ≥ load current × 1.2
③ Breaking capacity ≥ short-circuit current
④ Trip characteristic matches the load type
Trip characteristics:
• Type B (3~5×): lighting, household
• Type C (5~10×): general motor loads (most commonly used)
• Type D (10~20×): heavy-duty starting, transformers
Case: a 5.5kW motor (rated current 11A) → choose a 16A type C breaker
① Rated voltage ≥ line voltage
② Rated current ≥ motor rated current × 1.25
③ Coil voltage matches the control circuit (220V or 24VDC)
④ Number of contacts meets the circuit requirements
⑤ Utilization category AC-3 is for motors (AC-1 for resistive loads)
Case: a 5.5kW motor at 380V/11A → choose a CJX2-1810 (18A) contactor
① Rated current ≥ motor rated current
② Setting current = motor rated current × 0.95~1.05
③ Use the standard type for star connection and the type with phase-loss protection for delta connection
④ Choose automatic or manual reset (as required by the process)
⑤ Ambient temperature affects the setting value
Case: a 5.5kW motor at 11A → choose a JR36-20, setting current 11A
Capacity = Σ power consumption of all devices × 1.3 (margin factor)
Typical load estimates:
• PLC:0.3~0.5A/base
• Relay coils: 0.05~0.1A each
• Solenoid valves: 0.1~0.3A each
• Touch screens: 0.5~1A
• Sensors: 0.02~0.05A each
Case: PLC + 5 relays + 10 sensors ≈ 2A → choose a 24V/3A switching power supply
Three main functions:
① Suppress harmonics: filter out the high-order harmonics generated by the VFD
② Limit current: limit short-circuit current and inrush current
③ Improve the power factor
Installation locations:
• Input reactor: at the VFD input (harmonic suppression)
• Output reactor: at the VFD output (protects motor insulation)
Case: adding a 3% reactor at the VFD input lowers THD from 80% to 30%
Function: filter out clutter, noise and interference in power or signal lines
Common types:
① Power filter (EMC): eliminates conducted interference on power lines
② Signal filter: removes noise from sensor/communication signals
③ RC filter: simple low-pass filtering
④ LC filter: high-power filtering
Application: add an EMC filter at the VFD input → meet electromagnetic compatibility requirements
Case: add a power filter to a servo drive → prevent interference with the PLC
Standard requirements (GB 50057):
• Independent lightning protection grounding: ≤10Ω
• Safety protective grounding: ≤4Ω
• AC working grounding: ≤4Ω
• DC working grounding: ≤1Ω
• Anti-static grounding: ≤100Ω
• Computer systems: ≤1Ω
Measurement method: earth resistance tester (measure every six months)
Remediation: if resistance is too high → add ground electrodes/deepen burial/replace the soil
Standard requirements:
• Low-voltage electrical equipment (380V): ≥0.5MΩ
• High-voltage motors (6kV/10kV): ≥10MΩ
• Cables: ≥1MΩ/km
• Household appliances: ≥2MΩ
• Transformers: ≥1MΩ
Measuring instrument: megohmmeter (hand-cranked insulation tester)
Note: discharge before measuring, and do not touch the test leads while measuring
Standard (GB 14711 — motors):
• Low-voltage motors: 2 × rated voltage + 1000V (a 380V motor → 1760V, usually taken as 2000V)
• High-voltage motors: 2.25 × rated voltage + 2000V
• Transformers: 1.85 × rated voltage
Test duration: 60 seconds (factory test), 1 second (batch sampling)
Leakage current: ≤10mA (low-voltage motors)
Principle: the pilot valve (small flow) controls the opening of the main valve (large flow)
Working process:
① Hydraulic pressure acts on the pilot spool
② When the set pressure is reached → the pilot valve opens → a small amount of oil returns to the tank
③ The pilot oil creates a pressure difference → the main spool moves up → the main valve opens → a large volume of oil overflows
Characteristics:
• Smooth pressure regulation with small pressure fluctuations
• Remote pressure regulation possible (connect a remote relief valve to the remote port)
• Works stably even at relatively large flows
• Can be used for unloading (solenoid relief valve)
Principle: hydraulic pressure acts directly on the spool and balances against the spring force
Working process:
① Hydraulic pressure → pushes the spool
② Pressure < spring force → the spool closes
③ Pressure ≥ spring force → the spool opens → oil overflows
Characteristics:
• Simple structure, fast response
• Relatively low pressure-regulation accuracy
• Noticeable pressure overshoot at high flow
• Suitable for small flows or as a safety valve
Applications: safety protection in low-flow systems, pilot stage of pilot-operated relief valves
Principle: uses throttling to reduce pressure and keep the outlet pressure constant
Working process:
① The outlet pressure is fed back to the pilot valve
② Outlet pressure rises → the pilot valve opens wider → the main spool moves up → throttling increases → outlet pressure drops
③ Outlet pressure drops → the pilot valve closes → the main spool moves down → throttling decreases → outlet pressure rises again
④ This keeps the outlet pressure stable at the set value
Difference from a relief valve: the reducing valve controls the outlet pressure, while a relief valve controls the inlet pressure
Throttle valve:
• Only adjusts the size of the throttle opening
• Strongly affected by load changes (larger load → smaller flow)
• Poor speed stability
• Inexpensive
Flow-control valve:
• A combination of a throttle valve + a pressure-compensator (differential-pressure reducing valve)
• Automatically compensates for flow fluctuations caused by load changes
• Good speed stability
• Relatively expensive
Selection: choose a flow-control valve when high speed stability is required; for general applications choose a throttle valve
Normal state: same as an ordinary check valve (free flow forward, blocked in reverse)
Pilot-operated state:
① Pressure oil is supplied to pilot port X
② The pilot piston pushes the valve open
③ Reverse flow is also possible (flow through in reverse)
Applications:
• Hydraulic lock (holding cylinder pressure)
• Preventing a vertical cylinder from drifting down
• Pressure holding/make-up oil in hydraulic circuits
Case: a vertical hydraulic press uses a pilot-operated check valve to prevent the slide from dropping under its own weight
Principle: a combination of a solenoid valve (pilot stage) + a hydraulically actuated valve (main stage)
Working process:
① The solenoid valve is energized → control oil enters both ends of the hydraulic valve
② The control oil pushes the main spool of the hydraulic valve
③ The main spool shifts → the main oil circuit is reversed
Characteristics:
• A small solenoid valve can control a large-flow hydraulic valve
• Smooth and adjustable shifting (shifting time adjustable)
• Suitable for large-flow systems
Applications: large-flow hydraulic systems such as injection-molding machines, die-casting machines and metallurgical equipment
Four main functions:
① Store energy: accumulates energy during intermittent operation and releases it at peak demand → allows a smaller pump
② Absorb pulsation: reduces the pressure pulsation of the hydraulic pump
③ Absorb shocks: reduces pressure surges when directional valves operate
④ Compensate leakage: maintains system pressure (pressure holding)
Types:
• Bladder type (most common): nitrogen + bladder
• Piston type: large flow
• Spring type: small flow
Case: a punch press uses an accumulator to supply instantaneous large flow → pump power reduced by 30%
Main types:
① Air-cooled cooler:
• Simple structure, easy to install
• Suitable for water-scarce environments
• Cooling effect is affected by ambient temperature
② Water-cooled cooler (shell-and-tube/plate type):
• High cooling efficiency
• Requires a cooling water source
• The plate type is the most efficient
③ Oil-cooled cooler:
• Uses cooling oil as the medium
• Used in special applications
Selection: low water temperature/abundant water supply → water cooling; water shortage/mobile equipment → air cooling
Key requirements:
① Capacity 3~5× the pump flow (2~3× for closed-loop systems)
② Separate the suction and return ports with a baffle to lengthen the oil circulation path
③ The suction port is at least 2 pipe diameters above the tank bottom
④ Provide a drain port (at the lowest point), a filler port and an air breather
⑤ A level gauge and a thermometer
⑥ Slope the tank bottom for easy cleaning
⑦ Coat the inner walls with oil-resistant anti-rust paint
Case: a 100L/min pump → reservoir capacity 300~500L
Common positions:
① Suction filter: pump inlet (protects the pump, pressure loss ≤0.02MPa)
② Return filter: system return line (the most common position)
③ Pressure-line filter: pump outlet (protects high-precision valves)
④ Circulation filtration: a separate circulation system
Filtration grade selection:
• Suction: 100~200μm
• Return: 10~25μm
• Servo systems: 3~5μm
Case: a servo valve system → a 5μm pressure-line filter + a 10μm return filter
Recommended flow velocities:
• Suction line: 0.5~1.5m/s (too high → cavitation)
• Return line: 1.5~3m/s
• Pressure line:
- <5MPa:2~4m/s
- 5~10MPa:3~5m/s
- >10MPa:4~6m/s
Pipe diameter calculation: d=√(4q/πv)
Case: a 40L/min pump at 6MPa → pressure line inner diameter ≈ √(4×40×1000/60/π/4)=14.5mm → choose φ18×2.5 seamless tube
This is basic knowledge that mechanical engineers should master.
For specific values and their meaning, refer to the relevant chapters of the Mechanical Design Handbook or look them up in the other modules of this software.
Two main categories:
① Contact type (reed switch):
• Mechanical contacts, low cost
• Limited life (about 100,000 operations)
• Contact bounce, requiring debounce circuitry
② Contactless type (Hall/magnetoresistive):
• Electronic switch, no contacts
• Long life (over a million operations)
• Fast response, no bounce
• Available with NPN/PNP output
Selection: long life/high frequency → contactless; price-sensitive → reed switch
Mounting methods:
① C-slot: drop-in types (SMC CG series, etc.)
② T-slot: clipped in from the side
③ Tie-rod mounting: fixed with bolts
④ Band mounting: strapped to the cylinder barrel with a band
Each cylinder has a corresponding dedicated sensor model
Different brands use different groove profiles, so sensors are not interchangeable
Note: the sensor mounting position determines whether it detects the extended or retracted end position
Standard maximum pressure: 0.7~1.0MPa (7~10kgf/cm²)
Common working pressure: 0.4~0.6MPa
Reasons:
• Above 1.0MPa → increased safety risk for pipes and fittings
• Below 0.3MPa → insufficient cylinder output force
Standards by country:
• China/Japan: 0.7MPa
• Europe: 0.7MPa
• USA: 100psi ≈ 0.69MPa
Case: general factory compressed-air lines use 0.5~0.6MPa
Common unit conversions:
1 atm = 760mmHg = 0.1013MPa = 101.3kPa = 1.033kgf/cm²
Common vacuum units:
• kPa: kilopascal (most commonly used)
• -60kPa means a vacuum of 60kPa (relative to atmospheric pressure)
• mmHg: millimeters of mercury
Conversion: 1kPa = 7.5mmHg, 1mmHg = 0.133kPa
Case: a vacuum suction cup operating at -60kPa ≈ -450mmHg
Standard: ISO 8573-1
Class code: solid particles/water/oil (e.g., class 1.4.3)
Common classes:
• General pneumatic components: class 3.4.3 (acceptable for oil-free lubricated cylinders)
• Pneumatic instruments/precision components: class 2.3.2
• Spray painting/food: class 1.2.1
In practice: an ordinary factory equipped only with a filter + dryer can reach class 3~4
Upgrade: when a higher class is needed, add a precision filter and a desiccant dryer
Two main categories:
① Refrigerated dryer:
• Cools the compressed air to a dew point of 2~10℃
• Water vapor condenses out
• Relatively low energy consumption
• Dew point not low enough (suitable for general applications)
② Desiccant dryer:
• Uses an adsorbent (molecular sieve/activated alumina) to adsorb moisture
• Dew point down to -20~-70℃
• Relatively high energy consumption
• Requires regeneration (heated/heatless)
Selection: general factories → refrigerated; precision electronics/spray painting → desiccant
Principle: compressed air passes through a bed of desiccant, and water molecules are captured by the adsorbent
Two-tower alternating operation:
Tower A adsorbs → tower B regenerates → switch over
Regeneration methods:
① Heatless regeneration (PSA): 10~15% of the product gas is depressurized and used for purging, with no heating
② Slightly heated regeneration: a small heater heats the purge gas
③ Heated regeneration: swept with externally heated air
Features: dew point down to -40~-70℃, air consumption 10~15% (heatless regeneration)
Case: a precision electronics plant requires a compressed-air dew point of -40℃ → choose a desiccant dryer
Principle: compressed air → precooler → refrigeration evaporator (cooled to 2~10℃) → water vapor condenses → moisture separator → discharge
Working process:
① Compressed air enters the precooler (heat exchange with the outgoing cold air)
② It enters the refrigeration evaporator and is cooled to the dew point
③ Condensed water droplets are separated and drained by the moisture separator
④ The cold air returns to the precooler to cool the incoming hot air (energy saving)
Features: dew point 2~10℃, low energy consumption, simple maintenance
Selection: choose by the flow rate to be handled (Nm³/min); standard equipment in general factories
Installation requirements:
① Install vertically with the drain port facing down
② Install downstream of the dryer
③ The air inlet direction must match the arrow on the body
④ Upstream of the pressure-reducing valve (withstands the highest pressure)
⑤ Allow at least 200mm of maintenance space
Types:
• Cyclone type: separates large water droplets by centrifugal force
• Cartridge type: filters fine oil droplets
• Coalescing type: small oil droplets coalesce into larger ones
Routine: check the automatic drain daily and clean the filter element regularly
Principle:
① No water: the float is at the bottom and the drain valve is closed
② Water accumulates: the float rises with the water level
③ Draining: the float reaches the set height → the drain valve opens → the accumulated water is discharged
④ Reset after draining: the water level drops → the float sinks → the drain valve closes
Types:
• Float type: no electricity, uses buoyancy (common)
• Electric type: controlled by a timer or level switch (reliable)
• Diaphragm type: driven by differential pressure
Note: clogging by debris is a common fault and requires regular cleaning
Theoretical output force:
Push force F = P×A (P is the working pressure, A the piston area)
Pull force F = P×(A-Arod) (Arod is the piston-rod area)
Actual output force = theoretical output force × load ratio
Recommended load ratios:
• Horizontal motion: 50~70%
• Vertical motion: 30~50%
• High-speed motion: 30~40%
Causes: seal friction, intake/exhaust resistance, starting inertia
Case: a φ40mm cylinder at 0.5MPa pushing horizontally → F=0.5×π×20²×0.6=377N≈38kgf
Main measures:
① Lower the working pressure (every 0.1MPa reduction saves about 7%)
② Reduce leakage (leaks waste the most; a φ1mm hole loses about 3000 yuan a year)
③ Shut off the air supply when not in use (solenoid valve + check valve)
④ Use proper pipe diameters to reduce pressure loss
⑤ Recover exhaust energy
⑥ Maintain filters regularly
Case: lowering the plant pressure from 0.6MPa to 0.5MPa → about 7% energy savings, tens of thousands of yuan saved in electricity annually
Basis:
① Compressed air flow rate (m³/min)
② Pipe length (the longer → the larger the diameter)
③ Allowable pressure loss (generally ≤0.01MPa/100m)
④ Fitting specifications
Pipe diameter reference:
• Flow 0.5m³/min: φ8~10mm
• Flow 1.0m³/min: φ12~16mm
• Flow 3.0m³/min: φ20~25mm
• Flow 5.0m³/min: φ32~40mm
Velocity limits: main line ≤6m/s, branch line ≤10m/s
Case: an air compressor at 10m³/min → main pipe DN50
Other quick references in this series:Tolerances and FitsSurface RoughnessMaterial Heat TreatmentCasting DesignGeometric TolerancesDimensional chainWelded StructuresSheet Metal StructuresShaft System DesignSealing DesignMaterial SelectionHeat treatmentDatum LocationTolerancing principle