Machine tool bases, motor flanges, and cover plates commonly use bolted joint groups, and poor selection often leads to slipping, gapping, and early bolt fracture. This article follows four steps — force analysis, preload and permissible stress, bolt diameter determination, and strength check — and gives complete examples of an ordinary bolt under a transverse load and of a bolted group under an overturning moment, so that after reading you can independently select a bolted joint group and give its size and property class.
A bolted joint group fastens two or more parts on the same joint face, and there are three common loads: transverse load (transmitted by friction at the joint face), torque (rotation about the centroid of the bolt group), and overturning moment (which opens the joint face on one side). Three mistakes are common in practice: first, when an ordinary bolted joint carries a transverse load, only the working tensile force is calculated and the preload is ignored, so the joint face slips in service; second, clearance-hole and reamed-hole bolts are mixed, with ordinary bolts still used at shear locations, so the hole wall crushes; third, the preload is set by feel with a wrench — too low and it slips, too high and it breaks the bolt or crushes the plate — with no control by property class.
| Parameter | Meaning | Unit |
|---|---|---|
| FΣ | Transverse external load | N |
| F0 | Preload of a single bolt | N |
| z | Number of bolts | pcs |
| m | Number of joint faces (friction faces) | pcs |
| f | Friction coefficient of the joint face | — |
| Ks | Anti-slip reliability factor | — |
| T | External torque | N·mm |
| ri | Distance from the axis of the i-th bolt to the tipping neutral axis / the center of rotation | mm |
| M | Overturning moment | N·mm |
| d1 | Bolt minor diameter | mm |
| d0 | Shank diameter of a reamed-hole bolt | mm |
| h | Minimum thickness of the sheared part | mm |
| σs | Yield strength of the bolt material | MPa |
| S | Safety factor | — |
| Item | Recommended value | Notes |
|---|---|---|
| Friction coefficient f (steel on steel, dry face) | 0.10~0.15 | Oiled 0.06~0.10; with roughness Ra3.2~6.3 take the upper limit |
| Anti-slip reliability factor Ks | 1.1~1.3 | With vibration take 1.2~1.3 |
| σs for grade 8.8 bolts | 640MPa | Grade 10.9 900MPa, grade 4.8 320MPa |
| Safety factor S when the preload is controlled | M6~M16 take 1.5~2.5; M16~M36 take 1.2~1.5 | When the preload is not controlled, take the larger value S=3~4 |
| Q235 bolt (grade 4.6) | σs=240MPa | General non-critical static-load joints |
| 45 steel, grade 8.8 | σs=640MPa | Commonly used for the main joints of equipment |
| Reamed hole [τ] (grade 8.8) | 190~240MPa | For static load take the lower limit |
| Reamed hole [σp] (cast iron part) | 180~280MPa | For steel parts take the higher value |
Given:A steel cover plate is bolted to a base with z=6 ordinary bolts and one joint face m=1; the transverse external load FΣ=12000N, the joint-face friction coefficient f=0.15, and moderate vibration, so take Ks=1.2; the bolt group also carries an overturning moment M=800000N·mm, with the 4 tension-side bolts at a distance ri=80mm from the neutral axis (symmetric arrangement, Σri²=4×80²=25600mm²).
Step 1, calculate the preload required by the transverse load:F0 = 1.2×12000/(6×1×0.15) = 14400/0.9 = 16000N。
Step 2, calculate the maximum additional tensile force from the overturning moment:Fmax = M·rmax/Σri² = 800000×80/25600 = 2500N. The total tensile force on a tension-side bolt is F2 = F0 + Fmax = 16000+2500 = 18500N (checked at the most unfavorable tension side).
Step 3, set the permissible stress:Select grade 8.8 bolts with σs=640MPa; with the preload controlled, take S=1.5, so [σ]=640/1.5=426.7MPa.
Step 4, back-calculate the required minor diameter:σca = 1.3·F2/(π·d1²/4) ≤ [σ], so d1² ≥ 4×1.3×18500/(π×426.7) = 96200/1340.5 = 71.77mm² and d1 ≥ 8.47mm.
Step 5, select the bolt and check it:Select M12 coarse thread, minor diameter d1=10.106mm, stress area As=92.7mm². The equivalent stress σca = 1.3×18500/(π×10.106²/4) = 24050/80.2 = 299.8MPa ≤ 426.7MPa, so it passes. Checking M10 as well (d1=8.376mm): σca = 24050/55.1 = 436.5MPa > 426.7MPa, which does not pass, so M10 is too small.
Conclusion:Select six M12 grade 8.8 ordinary hex-head bolts, with the preload controlled at 16000N (corresponding to a torque of about 280N·m, estimated at a friction coefficient of 0.15~0.2); the total tensile force on a tension-side bolt is 18500N, the equivalent stress is about 300MPa, and the safety margin is about 1.4 times.
If you have no idea for the structure, browse the full-line 3D models (sorting machines, feeders, etc., with parts lists) in the "MOULDL Model Library (mouldl Model Library)"; for data, check them again against the "BST Technical Handbook" to be safer.
This article was compiled by Baist Technology (BST) as a reference for mechanical selection.