Bolted joint group calculation in 4 steps: choose the right bolt size with a transverse-load and overturning-moment example

Summary

Machine tool bases, motor flanges, and cover plates commonly use bolted joint groups, and poor selection often leads to slipping, gapping, and early bolt fracture. This article follows four steps — force analysis, preload and permissible stress, bolt diameter determination, and strength check — and gives complete examples of an ordinary bolt under a transverse load and of a bolted group under an overturning moment, so that after reading you can independently select a bolted joint group and give its size and property class.

Body

Application Scenario and Problem Background

A bolted joint group fastens two or more parts on the same joint face, and there are three common loads: transverse load (transmitted by friction at the joint face), torque (rotation about the centroid of the bolt group), and overturning moment (which opens the joint face on one side). Three mistakes are common in practice: first, when an ordinary bolted joint carries a transverse load, only the working tensile force is calculated and the preload is ignored, so the joint face slips in service; second, clearance-hole and reamed-hole bolts are mixed, with ordinary bolts still used at shear locations, so the hole wall crushes; third, the preload is set by feel with a wrench — too low and it slips, too high and it breaks the bolt or crushes the plate — with no control by property class.

Selection Calculation

Core Formulas

Parameter description

ParameterMeaningUnit
FΣTransverse external loadN
F0Preload of a single boltN
zNumber of boltspcs
mNumber of joint faces (friction faces)pcs
fFriction coefficient of the joint face—
KsAnti-slip reliability factor—
TExternal torqueN·mm
riDistance from the axis of the i-th bolt to the tipping neutral axis / the center of rotationmm
MOverturning momentN·mm
d1Bolt minor diametermm
d0Shank diameter of a reamed-hole boltmm
hMinimum thickness of the sheared partmm
σsYield strength of the bolt materialMPa
SSafety factor—

Recommended Value Table

ItemRecommended valueNotes
Friction coefficient f (steel on steel, dry face)0.10~0.15Oiled 0.06~0.10; with roughness Ra3.2~6.3 take the upper limit
Anti-slip reliability factor Ks1.1~1.3With vibration take 1.2~1.3
σs for grade 8.8 bolts640MPaGrade 10.9 900MPa, grade 4.8 320MPa
Safety factor S when the preload is controlledM6~M16 take 1.5~2.5; M16~M36 take 1.2~1.5When the preload is not controlled, take the larger value S=3~4
Q235 bolt (grade 4.6)σs=240MPaGeneral non-critical static-load joints
45 steel, grade 8.8σs=640MPaCommonly used for the main joints of equipment
Reamed hole [τ] (grade 8.8)190~240MPaFor static load take the lower limit
Reamed hole [σp] (cast iron part)180~280MPaFor steel parts take the higher value

Complete Worked Example

Given:A steel cover plate is bolted to a base with z=6 ordinary bolts and one joint face m=1; the transverse external load FΣ=12000N, the joint-face friction coefficient f=0.15, and moderate vibration, so take Ks=1.2; the bolt group also carries an overturning moment M=800000N·mm, with the 4 tension-side bolts at a distance ri=80mm from the neutral axis (symmetric arrangement, Σri²=4×80²=25600mm²).

Step 1, calculate the preload required by the transverse load:F0 = 1.2×12000/(6×1×0.15) = 14400/0.9 = 16000N。

Step 2, calculate the maximum additional tensile force from the overturning moment:Fmax = M·rmax/Σri² = 800000×80/25600 = 2500N. The total tensile force on a tension-side bolt is F2 = F0 + Fmax = 16000+2500 = 18500N (checked at the most unfavorable tension side).

Step 3, set the permissible stress:Select grade 8.8 bolts with σs=640MPa; with the preload controlled, take S=1.5, so [σ]=640/1.5=426.7MPa.

Step 4, back-calculate the required minor diameter:σca = 1.3·F2/(π·d1²/4) ≤ [σ], so d1² ≥ 4×1.3×18500/(π×426.7) = 96200/1340.5 = 71.77mm² and d1 ≥ 8.47mm.

Step 5, select the bolt and check it:Select M12 coarse thread, minor diameter d1=10.106mm, stress area As=92.7mm². The equivalent stress σca = 1.3×18500/(π×10.106²/4) = 24050/80.2 = 299.8MPa ≤ 426.7MPa, so it passes. Checking M10 as well (d1=8.376mm): σca = 24050/55.1 = 436.5MPa > 426.7MPa, which does not pass, so M10 is too small.

Conclusion:Select six M12 grade 8.8 ordinary hex-head bolts, with the preload controlled at 16000N (corresponding to a torque of about 280N·m, estimated at a friction coefficient of 0.15~0.2); the total tensile force on a tension-side bolt is 18500N, the equivalent stress is about 300MPa, and the safety margin is about 1.4 times.

Result Verification and Pitfall Reminders

  1. An ordinary bolt under a transverse load must have its preload calculated for friction-based load transfer, and the diameter must not be chosen directly from the working tensile force; once the joint face becomes oily or rusted, f drops, so re-check the anti-slip condition and consider applying MoS2 or adding dowel pins.
  2. Under an overturning moment you must ensure both that the compression-side joint face is not crushed (compressive stress ≤ the permissible compressive stress of the clamped parts) and that the residual preload on the tension side is greater than 0 (to prevent gapping and leakage of air or water); do not check only the bolt strength.
  3. Reamed-hole bolts may be used only at shear locations, with the shank-to-hole fit normally H7/m6 or H7/r6; using an ordinary bolt at a reamed-hole location inevitably causes hole-wall bearing and shear failure.
  4. Within one bolt group the bolt diameter and property class should be uniform to avoid uneven loading; set the preload to F0 with a torque wrench or the turn-of-nut method, and tighten critical joints in 2~3 passes in a diagonal pattern.

Suggested Illustrations

If you have no idea for the structure, browse the full-line 3D models (sorting machines, feeders, etc., with parts lists) in the "MOULDL Model Library (mouldl Model Library)"; for data, check them again against the "BST Technical Handbook" to be safer.

This article was compiled by Baist Technology (BST) as a reference for mechanical selection.

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL