Standard: GB/T 15706-2012(ISO 12100)
Machine safety has two parts: design + use
Eliminate or reduce the risk by design rather than relying on guard devices
Highest priority
Three-step method:
1. Step 1: inherently safe design
Eliminate the hazard
e.g. use low voltage instead of high voltage, use radii instead of sharp corners
2. Step 2: safety protection+supplementary protective measures
Guard the hazards that cannot be eliminated
e.g. guards, interlocking devices
3. Step 3: information for use
Provide instructions, training and warnings
e.g. signs, instructions and training
Risk = severity of injury × probability of occurrence × frequency of exposure
1. determine the limits (use / space / time)
2. identify hazards (mechanical / electrical / thermal / noise / radiation / material / ergonomic)
3. risk estimation (severity + probability + exposure)
4. risk evaluation (is it acceptable)
5. risk reduction (three-step method)
1. mechanical hazards
- crushing / shearing / cutting / entanglement / ingestion / impact / friction / high-pressure injection
2. electricalhazard
- electric shock / burns / short circuit
3. Thermal hazards
- flame / explosion / hot surfaces / thermal radiation
4. noisehazard
5. vibrationhazard
6. radiation hazard
7. material / substance hazard
8. ergonomic hazard
9. combined hazard
No design can eliminate risk completely
Residual risk must be communicated to the user (information for use)
Followsafety functionofpart:
1. safety control system
2. safety guard
3. safety information
Safety functionrequirement:
- reliability (will not fail)
- foreseeability (predictable behaviour)
- fail-safe (safe on failure)
- maintainability
1. assess all accessible parts
2. considerreasonably foreseeable misuse
3. considermaintenance, cleaning and faults
4. considerwhole life cycle
5. technically and economically feasible
1. SIL (Safety Integrity Level, IEC 61508/62061)
Safety Integrity Level
Divided into 4 levels: SIL1~SIL4
SIL4highest (continuous control)
MachinegeneralSIL1~SIL3
2. PL (Performance Level, ISO 13849-1)
Performance Level
Divided into 5 levels: PL a~PL e
PLehighest
Machine safetycommonly used
3. Category (Category, ISO 13849-1)
Divided into 5 categories: B, 1, 2, 3, 4
Blowest, 4highest
PL a ≈ SIL1(low)
PL b ≈ SIL1
PL c ≈ SIL1
PL d ≈ SIL2
PL e ≈ SIL3
Category B → PL a/b
Category 1 → PL c
Category 2 → PL d
Category 3 → PL d/e
Category 4 → PL e
1. risk assessment
- severity of injury (S1slight/S2serious / fatal)
- frequency of exposure (F1 infrequent / F2 frequent)
- possibility of avoidance (P1may/P2notmay)
2. risk graph determinationPL
S1+F1+P1 → PL a
S1+F1+P2 → PL b
S1+F2+P1 → PL b
S1+F2+P2 → PL c
S2+F1+P1 → PL c
S2+F1+P2 → PL d
S2+F2+P1 → PL d
S2+F2+P2 → PL e
3. typicalPLrequirement
E-stop: PLr c (general)/PLr d (high risk)
Guard door: PLr d
Safety light grid: PLr e (high risk)
Two-hand control: PLr d
PL a: PFHd < 10⁻⁵/h
PL b: < 3×10⁻⁵/h? Incorrect, corrected to:
PL a: 10⁻⁵~10⁻⁴/h
PL b: 3×10⁻⁵~10⁻⁴/h
PL c: 10⁻⁶~10⁻⁵/h
PL d: 10⁻⁷~10⁻⁶/h
PL e: 10⁻⁸~10⁻⁷/h
PL a: MTTFdlow
PL e: MTTFdhigh (>100year)
Category B: basic requirements
Category 1: validated components+MTTFdhigh
Category 2: monitoring + testing
Category 3: redundancy + fault detection (single fault safety)
Category 4: redundancy + high diagnostic coverage + cumulative fault tolerance
PL c: basic safety relay
PL d: standardsafety relay (such asPilz PNOZ)
PL e: high performancesafety relay
1. calculationPFHd
2. andPLrequirementcomparison
3. confirmsatisfy
1. determinelimit
a. uselimit
- intended use
- reasonably foreseeable misuse
- usepersonnel (operate/maintenance/cleaning)
b. spatial limitation
- mounting position
- working space
c. time limitation
- design life
- recommended maintenance interval
2. hazard identification
The system identifies all hazards
Checklist method / brainstorming / FTA
Typicalhazard:
- mechanical (moving parts / sharp edges / gravity)
- electrical (electric shock / static)
- thermal (high / low temperature / flame)
- noise
- vibration
- radiation (laser / electromagnetic / ionising)
- material (toxic / flammable / dust)
- ergonomic (working posture / lighting)
- environment
3. risk estimation
Eachhazardassessment:
a. severity of injury
S1: slight (recoverable)
S2: serious (irreversible / fatal)
b. frequency of exposure
F1: infrequent
F2: frequent
c. possibility of avoidance
P1: possible (can be avoided)
P2: impossible (cannot be avoided)
d. Probability of occurrence
4. risk evaluation
Is the risk acceptable?
Compare against ALARP (as low as reasonably practicable)
Regulatory requirements
Industry standards
Company policy
5. risk reduction (three-step method)
Step1: inherently safe design
Step2: safety protection+supplementary protective measures
Step3: information for use
Reducerearheavynewassessment
Until it is acceptable
1. risk assessment table
No. | Hazard | Location | S | F | P | Risk level | Measures | Residual risk
2. hazardlist
3. risk matrix
4. risk graph (ISO 13849)
5. Safety Requirements Specification (SRS)
Press:
Hazard: the moving die crushes fingers
Severity: S2 (amputation / fatal)
Exposure: F2(frequent loading and unloading)
Avoid: P2(cannot avoid quickly)
→ PL erequirement
Measure:
1. Inherently safe: change to automatic loading (less human intervention)
2. protection: safety light grid (PL e)
3. interlock: guard door switch+safety relay
4. two-hand control buttons
5. Emergency stop
6. warning sign
7. Training
1. risk assessment report
2. safety requirements list
3. verification report
4. CEtechnical documentation (such asmust)
Meaning of the colours:
1. red — prohibition / stop / fire fighting
E-stop button
Fire extinguisher
Prohibition sign
2. yellow — warning/Note
Hazardous areamarking
Warning sign
Alternating yellow and black stripes
3. blue — mandatory action
Protective equipment must be worn
Mustearthing
Instructionsigns
4. green — safety/emergency
First aid kit
Emergency exit
Safety signs
5. red+white — prohibit
No entry
6. yellow+black — warning
Hazardous area
1. red+white
2. yellow+black
3. blue+white
4. green+white
5. black+white
1. prohibition sign
Red circle with a diagonal bar
White background with a red circle and diagonal bar
Blacksymbol
e.g. no smoking / no entry
2. warning sign
Yellowtriangle
Black border
Blacksymbol
e.g. beware of electric shock / beware of machinery
3. instructionsigns
Bluecircular
Whitesymbol
e.g. must wear a helmet / must be earthed
4. information sign
Greensquare
White pictogram / text
e.g. emergency exit / first aid station
5. fire equipment sign
Redsquare
Whitesymbol
e.g. fire extinguisher / fire hydrant
Viewing distance L (m) | Sign outer diameter (mm)
L≤2 | 50~100
L≤5 | 100~200
L≤10 | 200~400
L≤15 | 400~600
1. Prominent
2. eye height
3. near the hazard
4. At the entrance
5. adequate lighting
Typicalmachine safety signs:
1. beware of machinery (yellow triangle + gear symbol)
2. beware of electric shock (yellow + lightning)
3. beware of hot surfaces (yellow + flame)
4. beware of rotation (yellow + circular arrow)
5. must wear eye protection (blue + goggles)
6. must wear a safety helmet (blue + helmet)
7. must wear gloves (blue + gloves)
8. do not enter (red + person)
9. emergency stop (red + hand)
10. Emergency exit (green + door + arrow)
Sign + explanatory text
e.g. beware of machinery
Danger! Moving parts
1. Self-adhesive PVC
2. aluminium plate
3. stainless steel (corrosive environment)
4. Illuminated (emergency)
1. Periodic inspection (damage / fading)
2. holdcleaning
3. replace what has failed
4. Not obstructed
5. Content is accurate
1. Protection against electric shock
a. protection against direct contact
- insulation (basic)
- guard (IP2X+)
- obstacle
- distance (safe distance)
b. protection against indirect contact
- automatic power disconnection (earthing + protective switch)
- double insulation (IIclassequipment)
- electrical isolation (isolating transformer)
- unearthed equipotential bonding
2. protective earthing
a. PE conductor
All accessible metal enclosures must be earthed
Earth resistance<4Ω(general)
<1Ω(precision)
b. equipotential bonding
All metal parts at the same potential
Prevents electric shock due to potential difference
c. earth conductor cross-section
Line conductor S (mm²) | PE conductor S_PE
S≤16 | S
16<S≤35 | 16
S>35 | S/2
3. insulation
a. Basic insulation
Between the live part and the accessible part
b. Supplementary insulation
In addition to double insulation
c. Reinforced insulation
Equivalent to double insulation
Insulation resistance:
Test with a 500V megohmmeter
> 1MΩ (basic)
> 2MΩ (reinforced)
4. withstand voltage test
Power-frequency withstand voltage:
Basic insulation: 1000V+2U
Reinforced insulation: 1500V+2U
For 1 minute
No breakdown / no arcing
5. short-circuit protection
Fuse / circuit breaker
Disconnection time < 5s (fixed equipment)
< 0.4s (hand-held equipment)
6. overload protection
Thermal overload relay
Current transformer + relay
7. Emergency stop
0class/1class/2class
See the separate entry
8. protection class (IP)
IPXX:
First position: solid
0: no protection
2: >12mm (finger)
4: > 1mm (wire)
5: dust protection
6: dust tight
Second position: liquid
0: no protection
1: water drops (vertical)
2: water drops (15°)
3: water sprays (60°)
4: water splashes (any direction)
5: water jets
6: powerful water jets
7: temporary immersion
8: continuous immersion
Typical:
IP20: inside a cabinet (finger protection)
IP54: general purpose (dust + splash)
IP65: water jet protection
IP67: temporary immersion
9. voltageclass
Safetyvoltage:
< 36V (dry)
< 24V (damp)
< 12V (in water)
SELV (extra-low voltage): < 42V
10. Conductor colours
Black: line conductor
Blue: neutral conductor
Yellow/green: PE
Red: control
Orange: interlock
1. protection classIP54+
2. Heat dissipation (air conditioning / fan)
3. Neat cable routing
4. clearly marked
5. E-stopred
6. Earth bar
7. Busbar
8. Maintenance access
9. Lock (prevents unauthorised entry)
10. warning sign
1. insulation resistance
2. withstand voltage
3. earth resistance
4. Protective function
5. Emergency stop
6. Marking
7. Documentation
1. electrical schematic
2. Wiring diagram
3. partlist
4. operatehandbook
5. maintenancehandbook
6. safety instructions
Mandatory marking for placing products on the EU market
Denotes conformity with the relevant EU directives
Suitable formachine (containssafetypart)
1. machine definition
At least one moving part
Powered (not human or animal powered)
+ specific functions (processing / moving / lifting)
2. Exception
Manually powered machinery (unless used for lifting)
Medical devices (separate directive)
Low-voltage electrical equipment (Low Voltage Directive)
Annex I:
1. inherently safe design
2. Control system
3. protectionmeasure
4. Information / warning
5. Maintenance
6. Electrical
7. others (noise / vibration / radiation)
1. self-declaration (ordinary machinery)
Manufacturer self-assessment
Technical documentation
DoC (Declaration of Conformity)
Affix the CE mark
2. notified body involvement (high risk)
Annex IV machinery (high-risk list)
Notified bodyassessment
EU type examination
Annex IVExample:
- cutting machine (manual loading)
- hand-held machinery
- certain wood-working machines
1. machine description
2. design drawings / calculations
3. risk assessment
4. safetymeasurelist
5. standard (harmonised standards)
6. Test report
7. Instruction manual
8. Manufacturing process
9. DoC
1. EN ISO 12100 (safety general principles)
2. EN ISO 13849(Safety Control)
3. EN ISO 14120(guard)
4. EN 60204-1(electrical)
5. EN 349(minimum clearance)
6. EN 574(two-hand control)
7. EN 999 (safe distances, now ISO 13855)
8. EN ISO 13855(safe distance)
9. EN 61496(light curtain)
1. risk assessment (ISO 12100)
2. Applicationharmonised standards
3. design+manufacture
4. preparation of the technical file
5. Assessment (self-assessment or notified body)
6. DoC signature
7. CEsigns
8. Keep the technical file for 10 years
9. market surveillance
Manufacturer declaration
Content:
- manufacturer information
- machine description
- applicable directives
- applicationstandard
- notified body (if applicable)
- signed by
- date
Dimensions≥5mm
Ratio 1:8 (CE)
Cannot be removed
Affixed to the nameplate / packaging
1. lowvoltageinstruction (LVD, 2014/35/EU)
50~1000VACequipment
2. Electromagnetic Compatibility (EMC, 2014/30/EU)
Electrical and electronic
3. pressureequipment (PED, 2014/68/EU)
Pressure vessels / pipework
4. ATEX (2014/34/EU)
Explosionenvironment
5. noise (2000/14/EC)
Outdoorequipmentnoise
China: CCC (mandatory for some products)
USA: UL / CSA (voluntary + market driven)
Japan: PSE
1. designphasecomply withstandard
2. prepare the technical file
3. risk assessment
4. retain all records
5. consult the notified body if necessary
6. periodic review
The design takes human body characteristics into account
Reduce fatigue / errors / injuries
1. Stature
male: 1678mm (50th percentile)
Female: 1570mm
Range: 1543~1838 (male)
2. standingoperate
Controlunitheight: 1000~1500mm
Display: 1400~1700mm
Buttonheight: 900~1400mm
3. Seated operation
Desktop: 720~760mm
Seat: 400~440mm
Display: 1100~1300mm
4. reach range
Reach forward: 600~700mm (easy)
Maximum: 800mm
Reach sideways: 500mm
1. Button
fingertip: 5~10N
palm: 10~50N
2. Handle / handwheel
One hand: 50~150N
Two hands: 100~300N
3. Foot pedal
Foot pedal: 30~100N
Maximum: 300N (short term)
4. Manual handling
male: 25kg (continuous)
female: 15kg
Maximum: 55kg (male, occasional)
1. Seated posture preferred
Reducefatigue
Foot pedal + handrail
2. Standing posture
Short-term operation
Anti-slip floor
Foot mat
3. Avoidance
Bending forward > 15°
Twisting > 15°
Overhead reach
Squatting / kneeling
1. field of view
Directly in front
Horizontal±30°(optimum)
Vertical±15°(optimum)
2. Viewing distance
Fine: 300~500mm
General: 500~700mm
Distant: > 700mm
3. lighting
Precisionmachining: 1000~2000lux
General machining: 300~500lux
Inspection: 750~1500lux
Walkways: 50~100lux
4. Display unit
Height: 15° below the eye level
Distance: 500~700mm
Character height: 3.5~5mm (at 700mm viewing distance)
Colour: green / yellow / red (state)
1. Button
Red: E-stop/stop
Green: start
Yellow: intervention / reset
Black / white: function
2. Knob
Clockwise: increase
Anti-clockwise: decrease
3. Switch
Up: on
Down: off
4. HMI panel
The button is large enough (> 10mm)
Spacing>5mm
Clearly defined feedback
Red: hazard/stop
Yellow: warning
Green: safety/Normal
Blue: instruction
White: neutral
1. standard
Continuous8h: 85dB (A)
Peak: 140dB(C)
2. Measures
Reduce the noise at source
Sound insulation
Sound absorption
Personal protection (ear plugs)
1. armvibration
8henergyequivalent: 5m/s²
2. Whole-body vibration
8h: 0.5m/s²
3. Measures
Damped handle
Suspended seat
Time-limited operation
1. Shift work
2~3 shifts
rest period
2. Work content
Monotonic avoidance
Cycle > 30s
Multi-function
3. training
Pre-job training
Periodic refresher training
Emergencytraining
The safety system must be validated after installation
Confirm that the function is correct
1. Installationinspection
- correct wiring
- component type
- mounting position
- marking
2. function testing
- E-stop: according tooff→standstill, return
- guard door: open → stop, closed → start permitted
- light curtain: interrupted → stop
- two-hand control: singlehandineffective, doublehandeffective
- safety mat: stepped on → stop
- STO: trigger→torque-free
3. response time
Time from trigger to stop
Measure + record
Comparisondesignrequirement
4. safe distanceValidation
Light curtaindistance
Safe Distance Calculation
The actual installation must be ≥ the calculated value
5. safety levelValidation
PL/SILcalculation
Circuit analysis
Failure mode analysis
1. manualtest
Press the E-stop / open the door / interrupt the light curtain
Observeresponse
2. instrument test
Oscilloscope (response time)
Multimeter (voltage)
Safety analyser
3. automatictest
SafetyPLCself-diagnosing
Periodic testing
1. equipment information
2. test items
3. test method
4. test result (pass / fail)
5. tested by / date
6. Signature
Safety functions degrade over time
Periodic inspectionensurereliable
1. daily (operator)
- E-stop function (before the shift)
- inspection (abnormalities)
- cleaning
2. monthly (maintenance)
- allE-stop
- guard doorinterlock
- light curtain
- two-hand control
3. quarterly (engineering)
- safety relay
- safety PLC diagnostics
- STO function
- response time
4. yearly (third party)
- comprehensive safety assessment
- PL / SIL review
- document update
- risk assessment update
1. physical inspection
- component failure
- loose wiring
- missing marking
- guard is intact
2. function testing
- each safety function
- record the result
3. parameter validation
- safe distance
- response time
- speed limit value
- limit value
4. Documentation
- inspectionrecord
- maintenance record
- change record
1. replace damaged components
- original type or equivalent
- the safety level is unchanged
2. Software / parameters
- backup
- update record
3. Calibration
- encoder
- Sensors
4. Cleaning
- curtain lens
- proximity switch
- safety mat
1. Validation report (on installation)
2. periodic inspectionrecord
3. maintenance record
4. Modification record
5. Accident record
6. Retention period: machine life + 10 years
1. periodic risk assessment
2. standards update
3. Accident analysis
4. Experience feedback
5. Continuous improvement
1. operator: daily checks + reporting
2. maintenance: periodic inspection+maintain
3. Engineering: validation + improvement
4. Management: policy + training + audits
5. Third party: annual assessment