GB/T 15706 Fundamental Concepts of Machine Safety

【GB/T 15706Fundamental Concepts of Machine Safety】

Standard: GB/T 15706-2012(ISO 12100)

Machine safety has two parts: design + use

【Inherently safe design】

Eliminate or reduce the risk by design rather than relying on guard devices

Highest priority

Three-step method:

1. Step 1: inherently safe design

Eliminate the hazard

e.g. use low voltage instead of high voltage, use radii instead of sharp corners

2. Step 2: safety protection+supplementary protective measures

Guard the hazards that cannot be eliminated

e.g. guards, interlocking devices

3. Step 3: information for use

Provide instructions, training and warnings

e.g. signs, instructions and training

【Risk Factors】

Risk = severity of injury × probability of occurrence × frequency of exposure

【Risk assessmentstep】

1. determine the limits (use / space / time)

2. identify hazards (mechanical / electrical / thermal / noise / radiation / material / ergonomic)

3. risk estimation (severity + probability + exposure)

4. risk evaluation (is it acceptable)

5. risk reduction (three-step method)

【Hazard Classification】

1. mechanical hazards

- crushing / shearing / cutting / entanglement / ingestion / impact / friction / high-pressure injection

2. electricalhazard

- electric shock / burns / short circuit

3. Thermal hazards

- flame / explosion / hot surfaces / thermal radiation

4. noisehazard

5. vibrationhazard

6. radiation hazard

7. material / substance hazard

8. ergonomic hazard

9. combined hazard

【Risk reductionrearofresidual risk】

No design can eliminate risk completely

Residual risk must be communicated to the user (information for use)

【Safety function】

Followsafety functionofpart:

1. safety control system

2. safety guard

3. safety information

Safety functionrequirement:

- reliability (will not fail)

- foreseeability (predictable behaviour)

- fail-safe (safe on failure)

- maintainability

【Design Principles】

1. assess all accessible parts

2. considerreasonably foreseeable misuse

3. considermaintenance, cleaning and faults

4. considerwhole life cycle

5. technically and economically feasible

Safety Levels SIL and PL

【Safety Level System】

1. SIL (Safety Integrity Level, IEC 61508/62061)

Safety Integrity Level

Divided into 4 levels: SIL1~SIL4

SIL4highest (continuous control)

MachinegeneralSIL1~SIL3

2. PL (Performance Level, ISO 13849-1)

Performance Level

Divided into 5 levels: PL a~PL e

PLehighest

Machine safetycommonly used

3. Category (Category, ISO 13849-1)

Divided into 5 categories: B, 1, 2, 3, 4

Blowest, 4highest

【Correspondence】

PL a ≈ SIL1(low)

PL b ≈ SIL1

PL c ≈ SIL1

PL d ≈ SIL2

PL e ≈ SIL3

Category B → PL a/b

Category 1 → PL c

Category 2 → PL d

Category 3 → PL d/e

Category 4 → PL e

【Selection Basis】

1. risk assessment

- severity of injury (S1slight/S2serious / fatal)

- frequency of exposure (F1 infrequent / F2 frequent)

- possibility of avoidance (P1may/P2notmay)

2. risk graph determinationPL

S1+F1+P1 → PL a

S1+F1+P2 → PL b

S1+F2+P1 → PL b

S1+F2+P2 → PL c

S2+F1+P1 → PL c

S2+F1+P2 → PL d

S2+F2+P1 → PL d

S2+F2+P2 → PL e

3. typicalPLrequirement

E-stop: PLr c (general)/PLr d (high risk)

Guard door: PLr d

Safety light grid: PLr e (high risk)

Two-hand control: PLr d

【PFHd (probability of dangerous failure)】

PL a: PFHd < 10⁻⁵/h

PL b: < 3×10⁻⁵/h? Incorrect, corrected to:

PL a: 10⁻⁵~10⁻⁴/h

PL b: 3×10⁻⁵~10⁻⁴/h

PL c: 10⁻⁶~10⁻⁵/h

PL d: 10⁻⁷~10⁻⁶/h

PL e: 10⁻⁸~10⁻⁷/h

【MTTFd (mean time to dangerous failure)】

PL a: MTTFdlow

PL e: MTTFdhigh (>100year)

【Design Requirements for Safety Parts】

Category B: basic requirements

Category 1: validated components+MTTFdhigh

Category 2: monitoring + testing

Category 3: redundancy + fault detection (single fault safety)

Category 4: redundancy + high diagnostic coverage + cumulative fault tolerance

【Safety Relay Selection】

PL c: basic safety relay

PL d: standardsafety relay (such asPilz PNOZ)

PL e: high performancesafety relay

【Validation】

1. calculationPFHd

2. andPLrequirementcomparison

3. confirmsatisfy

Machine Safety Risk Assessment Method

【Risk assessmentprocess (ISO 12100)】

1. determinelimit

a. uselimit

- intended use

- reasonably foreseeable misuse

- usepersonnel (operate/maintenance/cleaning)

b. spatial limitation

- mounting position

- working space

c. time limitation

- design life

- recommended maintenance interval

2. hazard identification

The system identifies all hazards

Checklist method / brainstorming / FTA

Typicalhazard:

- mechanical (moving parts / sharp edges / gravity)

- electrical (electric shock / static)

- thermal (high / low temperature / flame)

- noise

- vibration

- radiation (laser / electromagnetic / ionising)

- material (toxic / flammable / dust)

- ergonomic (working posture / lighting)

- environment

3. risk estimation

Eachhazardassessment:

a. severity of injury

S1: slight (recoverable)

S2: serious (irreversible / fatal)

b. frequency of exposure

F1: infrequent

F2: frequent

c. possibility of avoidance

P1: possible (can be avoided)

P2: impossible (cannot be avoided)

d. Probability of occurrence

4. risk evaluation

Is the risk acceptable?

Compare against ALARP (as low as reasonably practicable)

Regulatory requirements

Industry standards

Company policy

5. risk reduction (three-step method)

Step1: inherently safe design

Step2: safety protection+supplementary protective measures

Step3: information for use

【Risk Reduction Iteration】

Reducerearheavynewassessment

Until it is acceptable

【Tools】

1. risk assessment table

No. | Hazard | Location | S | F | P | Risk level | Measures | Residual risk

2. hazardlist

3. risk matrix

4. risk graph (ISO 13849)

5. Safety Requirements Specification (SRS)

【Typicalrisk assessmentExample】

Press:

Hazard: the moving die crushes fingers

Severity: S2 (amputation / fatal)

Exposure: F2(frequent loading and unloading)

Avoid: P2(cannot avoid quickly)

→ PL erequirement

Measure:

1. Inherently safe: change to automatic loading (less human intervention)

2. protection: safety light grid (PL e)

3. interlock: guard door switch+safety relay

4. two-hand control buttons

5. Emergency stop

6. warning sign

7. Training

【Documentation】

1. risk assessment report

2. safety requirements list

3. verification report

4. CEtechnical documentation (such asmust)

Safety Colours and Safety Signs (GB 2893/2894)

【Safety colours (GB 2893)】

Meaning of the colours:

1. red — prohibition / stop / fire fighting

E-stop button

Fire extinguisher

Prohibition sign

2. yellow — warning/Note

Hazardous areamarking

Warning sign

Alternating yellow and black stripes

3. blue — mandatory action

Protective equipment must be worn

Mustearthing

Instructionsigns

4. green — safety/emergency

First aid kit

Emergency exit

Safety signs

5. red+white — prohibit

No entry

6. yellow+black — warning

Hazardous area

【Contrast colour】

1. red+white

2. yellow+black

3. blue+white

4. green+white

5. black+white

【Safety signs (GB 2894)】

1. prohibition sign

Red circle with a diagonal bar

White background with a red circle and diagonal bar

Blacksymbol

e.g. no smoking / no entry

2. warning sign

Yellowtriangle

Black border

Blacksymbol

e.g. beware of electric shock / beware of machinery

3. instructionsigns

Bluecircular

Whitesymbol

e.g. must wear a helmet / must be earthed

4. information sign

Greensquare

White pictogram / text

e.g. emergency exit / first aid station

5. fire equipment sign

Redsquare

Whitesymbol

e.g. fire extinguisher / fire hydrant

【Signsdimensions】

Viewing distance L (m) | Sign outer diameter (mm)

L≤2 | 50~100

L≤5 | 100~200

L≤10 | 200~400

L≤15 | 400~600

【Mounting position】

1. Prominent

2. eye height

3. near the hazard

4. At the entrance

5. adequate lighting

【Machine safety signs】

Typicalmachine safety signs:

1. beware of machinery (yellow triangle + gear symbol)

2. beware of electric shock (yellow + lightning)

3. beware of hot surfaces (yellow + flame)

4. beware of rotation (yellow + circular arrow)

5. must wear eye protection (blue + goggles)

6. must wear a safety helmet (blue + helmet)

7. must wear gloves (blue + gloves)

8. do not enter (red + person)

9. emergency stop (red + hand)

10. Emergency exit (green + door + arrow)

【Supplementary text】

Sign + explanatory text

e.g. beware of machinery

Danger! Moving parts

【Material】

1. Self-adhesive PVC

2. aluminium plate

3. stainless steel (corrosive environment)

4. Illuminated (emergency)

【Maintenance】

1. Periodic inspection (damage / fading)

2. holdcleaning

3. replace what has failed

4. Not obstructed

5. Content is accurate

Electrical Safety Design (IEC 60204)

【IEC 60204machineelectrical equipmentsafety】

1. Protection against electric shock

a. protection against direct contact

- insulation (basic)

- guard (IP2X+)

- obstacle

- distance (safe distance)

b. protection against indirect contact

- automatic power disconnection (earthing + protective switch)

- double insulation (IIclassequipment)

- electrical isolation (isolating transformer)

- unearthed equipotential bonding

2. protective earthing

a. PE conductor

All accessible metal enclosures must be earthed

Earth resistance<4Ω(general)

<1Ω(precision)

b. equipotential bonding

All metal parts at the same potential

Prevents electric shock due to potential difference

c. earth conductor cross-section

Line conductor S (mm²) | PE conductor S_PE

S≤16 | S

16<S≤35 | 16

S>35 | S/2

3. insulation

a. Basic insulation

Between the live part and the accessible part

b. Supplementary insulation

In addition to double insulation

c. Reinforced insulation

Equivalent to double insulation

Insulation resistance:

Test with a 500V megohmmeter

> 1MΩ (basic)

> 2MΩ (reinforced)

4. withstand voltage test

Power-frequency withstand voltage:

Basic insulation: 1000V+2U

Reinforced insulation: 1500V+2U

For 1 minute

No breakdown / no arcing

5. short-circuit protection

Fuse / circuit breaker

Disconnection time < 5s (fixed equipment)

< 0.4s (hand-held equipment)

6. overload protection

Thermal overload relay

Current transformer + relay

7. Emergency stop

0class/1class/2class

See the separate entry

8. protection class (IP)

IPXX:

First position: solid

0: no protection

2: >12mm (finger)

4: > 1mm (wire)

5: dust protection

6: dust tight

Second position: liquid

0: no protection

1: water drops (vertical)

2: water drops (15°)

3: water sprays (60°)

4: water splashes (any direction)

5: water jets

6: powerful water jets

7: temporary immersion

8: continuous immersion

Typical:

IP20: inside a cabinet (finger protection)

IP54: general purpose (dust + splash)

IP65: water jet protection

IP67: temporary immersion

9. voltageclass

Safetyvoltage:

< 36V (dry)

< 24V (damp)

< 12V (in water)

SELV (extra-low voltage): < 42V

10. Conductor colours

Black: line conductor

Blue: neutral conductor

Yellow/green: PE

Red: control

Orange: interlock

【Control cabinet design】

1. protection classIP54+

2. Heat dissipation (air conditioning / fan)

3. Neat cable routing

4. clearly marked

5. E-stopred

6. Earth bar

7. Busbar

8. Maintenance access

9. Lock (prevents unauthorised entry)

10. warning sign

【Test】

1. insulation resistance

2. withstand voltage

3. earth resistance

4. Protective function

5. Emergency stop

6. Marking

7. Documentation

【Documentation】

1. electrical schematic

2. Wiring diagram

3. partlist

4. operatehandbook

5. maintenancehandbook

6. safety instructions

CE Marking and the Machinery Directive

【CEsigns】

Mandatory marking for placing products on the EU market

Denotes conformity with the relevant EU directives

【Machinery Directive2006/42/EC】

Suitable formachine (containssafetypart)

1. machine definition

At least one moving part

Powered (not human or animal powered)

+ specific functions (processing / moving / lifting)

2. Exception

Manually powered machinery (unless used for lifting)

Medical devices (separate directive)

Low-voltage electrical equipment (Low Voltage Directive)

【Essential Health and Safety Requirements (EHSR)】

Annex I:

1. inherently safe design

2. Control system

3. protectionmeasure

4. Information / warning

5. Maintenance

6. Electrical

7. others (noise / vibration / radiation)

【Conformity assessment】

1. self-declaration (ordinary machinery)

Manufacturer self-assessment

Technical documentation

DoC (Declaration of Conformity)

Affix the CE mark

2. notified body involvement (high risk)

Annex IV machinery (high-risk list)

Notified bodyassessment

EU type examination

Annex IVExample:

- cutting machine (manual loading)

- hand-held machinery

- certain wood-working machines

【Technical documentationcontent】

1. machine description

2. design drawings / calculations

3. risk assessment

4. safetymeasurelist

5. standard (harmonised standards)

6. Test report

7. Instruction manual

8. Manufacturing process

9. DoC

【Harmonised standards】

1. EN ISO 12100 (safety general principles)

2. EN ISO 13849(Safety Control)

3. EN ISO 14120(guard)

4. EN 60204-1(electrical)

5. EN 349(minimum clearance)

6. EN 574(two-hand control)

7. EN 999 (safe distances, now ISO 13855)

8. EN ISO 13855(safe distance)

9. EN 61496(light curtain)

【Certification process】

1. risk assessment (ISO 12100)

2. Applicationharmonised standards

3. design+manufacture

4. preparation of the technical file

5. Assessment (self-assessment or notified body)

6. DoC signature

7. CEsigns

8. Keep the technical file for 10 years

9. market surveillance

【DoC (Declaration of Conformity)】

Manufacturer declaration

Content:

- manufacturer information

- machine description

- applicable directives

- applicationstandard

- notified body (if applicable)

- signed by

- date

【CEsigns】

Dimensions≥5mm

Ratio 1:8 (CE)

Cannot be removed

Affixed to the nameplate / packaging

【Other relevant directives】

1. lowvoltageinstruction (LVD, 2014/35/EU)

50~1000VACequipment

2. Electromagnetic Compatibility (EMC, 2014/30/EU)

Electrical and electronic

3. pressureequipment (PED, 2014/68/EU)

Pressure vessels / pipework

4. ATEX (2014/34/EU)

Explosionenvironment

5. noise (2000/14/EC)

Outdoorequipmentnoise

【ChinaCCC/CSA/UL】

China: CCC (mandatory for some products)

USA: UL / CSA (voluntary + market driven)

Japan: PSE

【Recommendation】

1. designphasecomply withstandard

2. prepare the technical file

3. risk assessment

4. retain all records

5. consult the notified body if necessary

6. periodic review

Ergonomics and Operational Safety

【Ergonomics (GB/T 12985)】

The design takes human body characteristics into account

Reduce fatigue / errors / injuries

【Human body dimensions (Chinese adults)】

1. Stature

male: 1678mm (50th percentile)

Female: 1570mm

Range: 1543~1838 (male)

2. standingoperate

Controlunitheight: 1000~1500mm

Display: 1400~1700mm

Buttonheight: 900~1400mm

3. Seated operation

Desktop: 720~760mm

Seat: 400~440mm

Display: 1100~1300mm

4. reach range

Reach forward: 600~700mm (easy)

Maximum: 800mm

Reach sideways: 500mm

【Force design】

1. Button

fingertip: 5~10N

palm: 10~50N

2. Handle / handwheel

One hand: 50~150N

Two hands: 100~300N

3. Foot pedal

Foot pedal: 30~100N

Maximum: 300N (short term)

4. Manual handling

male: 25kg (continuous)

female: 15kg

Maximum: 55kg (male, occasional)

【Posturedesign】

1. Seated posture preferred

Reducefatigue

Foot pedal + handrail

2. Standing posture

Short-term operation

Anti-slip floor

Foot mat

3. Avoidance

Bending forward > 15°

Twisting > 15°

Overhead reach

Squatting / kneeling

【Vision】

1. field of view

Directly in front

Horizontal±30°(optimum)

Vertical±15°(optimum)

2. Viewing distance

Fine: 300~500mm

General: 500~700mm

Distant: > 700mm

3. lighting

Precisionmachining: 1000~2000lux

General machining: 300~500lux

Inspection: 750~1500lux

Walkways: 50~100lux

4. Display unit

Height: 15° below the eye level

Distance: 500~700mm

Character height: 3.5~5mm (at 700mm viewing distance)

Colour: green / yellow / red (state)

【Controldesign】

1. Button

Red: E-stop/stop

Green: start

Yellow: intervention / reset

Black / white: function

2. Knob

Clockwise: increase

Anti-clockwise: decrease

3. Switch

Up: on

Down: off

4. HMI panel

The button is large enough (> 10mm)

Spacing>5mm

Clearly defined feedback

【Colourcoding】

Red: hazard/stop

Yellow: warning

Green: safety/Normal

Blue: instruction

White: neutral

【Noisecontrol】

1. standard

Continuous8h: 85dB (A)

Peak: 140dB(C)

2. Measures

Reduce the noise at source

Sound insulation

Sound absorption

Personal protection (ear plugs)

【Vibrationcontrol】

1. armvibration

8henergyequivalent: 5m/s²

2. Whole-body vibration

8h: 0.5m/s²

3. Measures

Damped handle

Suspended seat

Time-limited operation

【Work organisation】

1. Shift work

2~3 shifts

rest period

2. Work content

Monotonic avoidance

Cycle > 30s

Multi-function

3. training

Pre-job training

Periodic refresher training

Emergencytraining

Safety Function Validation and Periodic Inspection

【Safety function validation】

The safety system must be validated after installation

Confirm that the function is correct

【Validationcontent】

1. Installationinspection

- correct wiring

- component type

- mounting position

- marking

2. function testing

- E-stop: according tooff→standstill, return

- guard door: open → stop, closed → start permitted

- light curtain: interrupted → stop

- two-hand control: singlehandineffective, doublehandeffective

- safety mat: stepped on → stop

- STO: trigger→torque-free

3. response time

Time from trigger to stop

Measure + record

Comparisondesignrequirement

4. safe distanceValidation

Light curtaindistance

Safe Distance Calculation

The actual installation must be ≥ the calculated value

5. safety levelValidation

PL/SILcalculation

Circuit analysis

Failure mode analysis

【Test method】

1. manualtest

Press the E-stop / open the door / interrupt the light curtain

Observeresponse

2. instrument test

Oscilloscope (response time)

Multimeter (voltage)

Safety analyser

3. automatictest

SafetyPLCself-diagnosing

Periodic testing

【Verification report】

1. equipment information

2. test items

3. test method

4. test result (pass / fail)

5. tested by / date

6. Signature

【Periodic inspection】

Safety functions degrade over time

Periodic inspectionensurereliable

【Inspection frequency】

1. daily (operator)

- E-stop function (before the shift)

- inspection (abnormalities)

- cleaning

2. monthly (maintenance)

- allE-stop

- guard doorinterlock

- light curtain

- two-hand control

3. quarterly (engineering)

- safety relay

- safety PLC diagnostics

- STO function

- response time

4. yearly (third party)

- comprehensive safety assessment

- PL / SIL review

- document update

- risk assessment update

【Inspectioncontent】

1. physical inspection

- component failure

- loose wiring

- missing marking

- guard is intact

2. function testing

- each safety function

- record the result

3. parameter validation

- safe distance

- response time

- speed limit value

- limit value

4. Documentation

- inspectionrecord

- maintenance record

- change record

【Maintenance】

1. replace damaged components

- original type or equivalent

- the safety level is unchanged

2. Software / parameters

- backup

- update record

3. Calibration

- encoder

- Sensors

4. Cleaning

- curtain lens

- proximity switch

- safety mat

【Record keeping】

1. Validation report (on installation)

2. periodic inspectionrecord

3. maintenance record

4. Modification record

5. Accident record

6. Retention period: machine life + 10 years

【Safety improvement】

1. periodic risk assessment

2. standards update

3. Accident analysis

4. Experience feedback

5. Continuous improvement

【Responsibility】

1. operator: daily checks + reporting

2. maintenance: periodic inspection+maintain

3. Engineering: validation + improvement

4. Management: policy + training + audits

5. Third party: annual assessment

Related quick references: Safety ProtectionSafety ControlEmergency Stop DesignSafety Distances

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL