Permanently fixed (removable only with tools)
Prevents entry into the hazardous area
1. strength
Withstand the expected load (leaning by a person / impact by a tool)
Allow for chip and coolant splash
2. Rigidity
Does not deform
Stable under vibration
3. opening dimensions (GB/T 12265)
The safe distance depends onopening shape and size
Slot opening:
Opening width e (mm) | minimum distance to the hazard point (mm)
e≤4 | canany value (a finger cannot enter)
4<e≤6 | ≥20
6<e≤8 | ≥30
8<e≤10 | ≥70
10<e≤12 | ≥120
12<e≤20 | ≥200
20<e≤30 | ≥850
Square / circular opening:
Opening diameter d | safe distance
d≤4 | any value
4<d≤8 | ≥30
8<d≤25 | ≥120
25<d≤40 | ≥850
40<d≤250| ≥900
4. material
- steel plate (commonly used)
- aluminium plate (light)
- perforated sheet (ventilated / see-through)
- acrylic (see-through)
- polycarbonate (impact resistant)
5. inspection window
Window the area that must be observed
Material: tempered glass/polycarbonate
Thickness: according toimpact
6. ventilation
Needed for heat dissipation and chip clearance
Openings must comply with safe distances
7. Maintenance
Removable (with tools)
Does not compromise safety
8. Marking
Warning sign
Operating instructions
1. fully enclosed
Fully enclosed
Highest protection
2. partially enclosed
Open at the top
Side protection
3. fence type
Railings + mesh
Isolation of a large area
4. local guarding
a specific hazard point
1. Bolted fixing (hexagon socket, tamper resistant)
2. welded
3. riveted
4. safety screw (special tool)
1. integrity (free of damage)
2. securely fastened
3. openingcomply withsafe distance
4. clearly marked
5. does not interfere with operation
The guard is opened→the hazard stops / cannot be started
Closed → start is then possible
1. typeA
Opened → machine stops (a machine already moving may stop with a delay)
Mostsimple
2. typeB
Opened → machine stops immediately (fast)
+interlock
3. typeC
Opened → machine stop+lock
Lock→preventclosestartmachine
+guard lock
1. mechanical limit switch
Simple
Easily bypassed
Not recommended for safety applications
2. magnetic switch
Non-contact
Can be bypassed (with a magnet)
3. coded (RFID)
Unique identification
Defeat protection
High safety level
Brands: EUCHNER, Pilz, SICK
Example: EUCHNER CTP
Coding method: RFID
Safety level: PL e
Number of codes: 3 billion+
Defeat protection: yes
4. electromagnetic lock
Door locking
Unlocking requires a condition (machine stop)
Locking force: 1000~3000N
Suitable: high risk
1. dual-channel redundancy
Two independent switches
Failure of either one has no effect
required for PL d and above
2. force-guided separation
Mechanical connection (not spring)
Contacts open directly when power is lost
Does not rely on a spring
3. diagnostic coverage
Monitor the contact state
Cross-fault detection
4. response time
<50ms (from opening to standstill)
1. door open → machine stops
2. door closed → no automatic start (manual required)(mustmanual)
3. door locked → until the hazard is cleared
4. emergency release→special tool
1. machine tool guard door
2. robot cell
3. isolating an automatic line
4. hazard area entry
1. safety level (PL)
2. coding (defeat protection)
3. lock (mustnotrequires)
4. releasemethod
5. Installationmethod
6. Wiring (contact configuration)
7. environment (IP/temperature)
Emitter + receiver
The human body is interrupted→a safety signal is output→standstill
Type 2: basic type
Slower response
Suitable for low risk
Type 4: high performance
Fast response
Self-diagnosing
Interference immunity
Suitable for high risk
14mm: finger detection
30mm: hand detection
70mm: arm detection
500mm: body detection
Selection:
Finger hazard (pressing / shearing): 14mm
Hand hazard (general machinery): 30mm
Body hazard (robot area): 70mm+
S = K×T + C
K — approach speed
Human body: 2000mm/s (walking + reaching)
Finger: 2000mm/s
T — total response time
T = T curtain + T control + T braking
Tlight curtain: 10~20ms
Tcontrol: 10~50ms
T braking: machine stopping time (measured)
C — additional distance
Resolution ≤ 40mm: C = 8×(d-14)
d — resolution
Resolution > 40mm: C = 850mm
Minimum distance limit:
S ≥ 100mm
Press: braking time200ms, curtain response15ms, controller20ms
Resolution 14mm
T = 15+20+200 = 235ms = 0.235s
C = 8×(14-14) = 0
S = 2000×0.235 + 0 = 470mm
Curtain mounting distance ≥ 470mm
Protective height = hazard height + margin
Human body: 1500mm (standing person height)
Finger/hand: extend above and below the hazard zone
Number of beams:
4 beams: protective height 160mm
8 beams: protective height 320mm
16 beams: protective height 640mm
1. align the emitter and receiver
2. distance within the rated range (0.2~7m)
3. vibration resistant
4. resistant to strong light interference
5. Avoid reflective surfaces (interference)
6. periodic function testing
OSSDOutput (safety semiconductor)
Dual channel
Cross-fault detection
1. safety relay
Light curtain→safety relay→contactor
2. safetyPLC
Light curtain→safetyPLC→follow
3. direct safety module
Light curtain→safety module→follow
SICK (Germany)
Omron (Japan)
Pilz (Germany)
Keyence (Japan)
Both buttons pressed simultaneously
Keeps hands out of the hazardous area
Type I: single
Both buttons pressed simultaneously
Releasing either one → stop
Simple
Type II: manual reset
Pressed simultaneously + held
Release → stop
Type III: synchronised
Must be simultaneous (0.5sinside)according tooff
+hold
+requires reset after release
1. Two buttons
Independently mounted
Spacing≥260mm (prevents one-handed operation)
Or fit a guard
2. simultaneity
Type III: 0.5spressed within
Invalid if timed out
3. Output
Dual-channel safety output
Maintained signal
4. return
Press again after release
Or manual reset
5. Position
The operator faces the hazardous area
One hand per button
Generalrequirement: PL d
High risk: PL e
Presstwo-hand control:
1. Two buttons (300mm spacing)
2. Type III (synchronised, 0.5s)
3. safety relay (PL d)
4. Output→pressstart
5. Release → stop
6. mustheavynewtwo-hand control
Two-hand control: normal production
Light grid: entry in abnormal situations
Both can coexist
1. button spacing too small (can be operated with one hand)
2. no simultaneity requirement
3. single channel (no redundancy)
4. Button can be jammed
1. suitable height (standing1000~1500mm)
2. prevents accidental operation
3. clearly marked
4. Guard (prevents one-handed operation)
Function: laid on the floor, a person steps on it→triggers a stop
Principle: internal contacts, closed / opened under pressure
Application:
1. around the robot cell
2. AGV path
3. entry to the automatic line area
4. floor of the hazardous area
1. dimensions: 300×300 ~ 1000×1500mm
2. thickness: 8~15mm
3. Triggering force: 30~50kg (adult)
4. response time: <50ms
5. Life: 10⁶ cycles
6. protection: IP67
1. level floor
2. edges fixed
3. multiple mats joined together (cover the area)
4. concealed wiring
5. anti-slip surface
Function: mounted on the edge of a moving part, hits an obstacle→standstill
Type:
1. pressure-sensitive edge
Rubber strip containing contacts
Triggered by pressure
2. pressure-sensitive bumper
Soft
Cushions and triggers
3. tactile strip
Flexible
Multi-point detection
Application:
1. automatic doors (anti-pinch)
2. AGV (anti-collision)
3. lift doors
4. robot end effector (anti-collision)
5. mobile platform
1. Length: custom made
2. triggering force: 10~50N
3. response: <20ms
4. protection: IP65
5. Life: 10⁶ cycles
Used with a safety relay: PL d
Used with a safety PLC: PL e
1. triggering force (prevents accidental operation by children or small animals)
2. response time
3. dimensions
4. environment (IP/temperature)
5. mechanical life
6. safety level
1. door types
a. hinged door
Commonly used
Opens towards the safe side
b. sliding door
Horizontal / vertical
Saves space
Requires a track
c. lifting door
Vertical lift
Motorised
Suitable for large openings
d. bi-parting door
Multi-panel
Large opening
2. door dimensions
a. maintenance door
600×1500mm (one person)
b. load/unload door
Depends on the workpiece
c. emergency exit
800×2000mm
3. material
Steel plate: high strength
Aluminium alloy: lightweight
Mesh: ventilated and see-through
Polycarbonate: see-through and impact resistant
4. interlock
Guard door switch (mechanical / magnetic / RFID)
Door locking (electromagnetic)
Safety level PL d/e
5. release
a. normal release
Door closed + machine stopped → can be opened
b. emergency release
Special tool / key
Emergency only
c. escape
Internal handle (to prevent trapping)
6. inspection window
Tempered glass/polycarbonate
Thickness (impact)
Position (so the hazard is visible)
Fasteninspection window
Cannot be opened
Material:
Tempered glass: 5~10mm
Laminated glass: shatter resistant
Polycarbonate: impact resistant
PMMA : economical
1. electromagnetic lock
Lock open / unlock when energised
Locking force1000~5000N
Status feedback
2. Mechanical lock + interlock switch
Machinestrength
+electrical interlock
3. electromagneticrelease
De-energisedrelease (fail-safe)
Lock when energised
Several doors sharing one safety system
Any door open → standstill
All doors closed → start permitted
1. high risk
Electromagnetic lock+interlock+light curtain
Multiheavyprotection
2. maintenance door
Lock + key
Key withdrawn → door open → machine stops
3. Emergency
Internal escape device
Emergencylighting
Alarm
1. door frame rigidity
2. reliable hinges
3. Door lock alignment
4. limit switch position
5. adjustmargin
6. clearly marked
1. Crushing
2. Shearing
3. cutting/cut off
4. Entanglement
5. inhalation/entanglement
6. Impact
7. friction / wear
8. high-pressure injection
1. Eliminate sharp edges and corners
ChamferR>0.5mm
Radiused corners
Deburring
2. reducemoving parts
Enclose the moving parts
Reduceexposure
3. Reduce the speed / force
Speed < 0.25m/s (can be avoided)
Force < 150N (can be broken free)
4. increase the clearance
> body part (crush prevention)
or < clearance (inaccessible)
5. Reduce the effect of gravity
Prevents falling (brake)
Prevents overturning (center of gravity)
6. alternative energy
Pneumatic → mechanical (energy reduction)
Low voltage → high voltage
1. fastenprotection (see the separate entry)
2. Interlock Guarding (see the separate entry)
3. light curtain (see the separate entry)
4. two-hand control (see the separate entry)
5. safety mat
1. rotating part
- shaft: sleeve guard
- coupling: enclosure
- gears / belts: fully enclosed
- chuck: guard + no start
2. Linear motion
- lead screw: telescopic bellows
- pneumatic cylinder: limit+buffering
- slide table: guard
3. Cutting zone
- machining: guard door + inspection window
- pressing: two-hand control + light curtain
4. Loading and unloading
- automatic loading (less human intervention)
- safety tooling
5. Maintenance point
- safety interlock
- lockde-energised
-apply tags (LOTO)
1. designphaseconsidersafety (inherently safe)
2. Protection takes precedence over warning
3. Multiple protection (redundancy)
4. fail-safe
5. considerreasonably foreseeable misuse
6. whole life cycle
7. Easy to maintain (without bypassing the safety)
1. Press
Two-hand control + light curtain + interlocked door
Clutch and brake monitoring
Streak / repeat protection
2. Lathe
Chuck guard + interlock
Chip guarding
E-stop
3. Robot
Fence + guard door + light curtain
Speed limit (SLS)
Limit (SLP)
4. conveyor line
E-stop pull cord (along the line)
Guard
Noisecontrol