Machine Safety Design · Safety Protection (Quick Reference)

Fixed Guard Design

【Fixed Guard】

Permanently fixed (removable only with tools)

Prevents entry into the hazardous area

【Designrequirement】

1. strength

Withstand the expected load (leaning by a person / impact by a tool)

Allow for chip and coolant splash

2. Rigidity

Does not deform

Stable under vibration

3. opening dimensions (GB/T 12265)

The safe distance depends onopening shape and size

Slot opening:

Opening width e (mm) | minimum distance to the hazard point (mm)

e≤4 | canany value (a finger cannot enter)

4<e≤6 | ≥20

6<e≤8 | ≥30

8<e≤10 | ≥70

10<e≤12 | ≥120

12<e≤20 | ≥200

20<e≤30 | ≥850

Square / circular opening:

Opening diameter d | safe distance

d≤4 | any value

4<d≤8 | ≥30

8<d≤25 | ≥120

25<d≤40 | ≥850

40<d≤250| ≥900

4. material

- steel plate (commonly used)

- aluminium plate (light)

- perforated sheet (ventilated / see-through)

- acrylic (see-through)

- polycarbonate (impact resistant)

5. inspection window

Window the area that must be observed

Material: tempered glass/polycarbonate

Thickness: according toimpact

6. ventilation

Needed for heat dissipation and chip clearance

Openings must comply with safe distances

7. Maintenance

Removable (with tools)

Does not compromise safety

8. Marking

Warning sign

Operating instructions

【Guardtype】

1. fully enclosed

Fully enclosed

Highest protection

2. partially enclosed

Open at the top

Side protection

3. fence type

Railings + mesh

Isolation of a large area

4. local guarding

a specific hazard point

【Installation】

1. Bolted fixing (hexagon socket, tamper resistant)

2. welded

3. riveted

4. safety screw (special tool)

【Inspection】

1. integrity (free of damage)

2. securely fastened

3. openingcomply withsafe distance

4. clearly marked

5. does not interfere with operation

Interlocking Guard

【Interlock GuardingPrinciple】

The guard is opened→the hazard stops / cannot be started

Closed → start is then possible

【Type】

1. typeA

Opened → machine stops (a machine already moving may stop with a delay)

Mostsimple

2. typeB

Opened → machine stops immediately (fast)

+interlock

3. typeC

Opened → machine stop+lock

Lock→preventclosestartmachine

+guard lock

【Interlock Switch Types】

1. mechanical limit switch

Simple

Easily bypassed

Not recommended for safety applications

2. magnetic switch

Non-contact

Can be bypassed (with a magnet)

3. coded (RFID)

Unique identification

Defeat protection

High safety level

Brands: EUCHNER, Pilz, SICK

Example: EUCHNER CTP

Coding method: RFID

Safety level: PL e

Number of codes: 3 billion+

Defeat protection: yes

4. electromagnetic lock

Door locking

Unlocking requires a condition (machine stop)

Locking force: 1000~3000N

Suitable: high risk

【Safety interlockdesign】

1. dual-channel redundancy

Two independent switches

Failure of either one has no effect

required for PL d and above

2. force-guided separation

Mechanical connection (not spring)

Contacts open directly when power is lost

Does not rely on a spring

3. diagnostic coverage

Monitor the contact state

Cross-fault detection

4. response time

<50ms (from opening to standstill)

【Interlock Logic】

1. door open → machine stops

2. door closed → no automatic start (manual required)(mustmanual)

3. door locked → until the hazard is cleared

4. emergency release→special tool

【Application】

1. machine tool guard door

2. robot cell

3. isolating an automatic line

4. hazard area entry

【Selection】

1. safety level (PL)

2. coding (defeat protection)

3. lock (mustnotrequires)

4. releasemethod

5. Installationmethod

6. Wiring (contact configuration)

7. environment (IP/temperature)

Safety Light Curtain (ESPE) Selection and Installation

【Safety Light Curtain Principle】

Emitter + receiver

The human body is interrupted→a safety signal is output→standstill

【Type (IEC 61496)】

Type 2: basic type

Slower response

Suitable for low risk

Type 4: high performance

Fast response

Self-diagnosing

Interference immunity

Suitable for high risk

【Resolution (detection capability)】

14mm: finger detection

30mm: hand detection

70mm: arm detection

500mm: body detection

Selection:

Finger hazard (pressing / shearing): 14mm

Hand hazard (general machinery): 30mm

Body hazard (robot area): 70mm+

【Safe Distance Calculation】

S = K×T + C

K — approach speed

Human body: 2000mm/s (walking + reaching)

Finger: 2000mm/s

T — total response time

T = T curtain + T control + T braking

Tlight curtain: 10~20ms

Tcontrol: 10~50ms

T braking: machine stopping time (measured)

C — additional distance

Resolution ≤ 40mm: C = 8×(d-14)

d — resolution

Resolution > 40mm: C = 850mm

Minimum distance limit:

S ≥ 100mm

【Calculation Example】

Press: braking time200ms, curtain response15ms, controller20ms

Resolution 14mm

T = 15+20+200 = 235ms = 0.235s

C = 8×(14-14) = 0

S = 2000×0.235 + 0 = 470mm

Curtain mounting distance ≥ 470mm

【Protectionheight】

Protective height = hazard height + margin

Human body: 1500mm (standing person height)

Finger/hand: extend above and below the hazard zone

Number of beams:

4 beams: protective height 160mm

8 beams: protective height 320mm

16 beams: protective height 640mm

【Installation】

1. align the emitter and receiver

2. distance within the rated range (0.2~7m)

3. vibration resistant

4. resistant to strong light interference

5. Avoid reflective surfaces (interference)

6. periodic function testing

【Output】

OSSDOutput (safety semiconductor)

Dual channel

Cross-fault detection

【Control Interface】

1. safety relay

Light curtain→safety relay→contactor

2. safetyPLC

Light curtain→safetyPLC→follow

3. direct safety module

Light curtain→safety module→follow

【Common Brands】

SICK (Germany)

Omron (Japan)

Pilz (Germany)

Keyence (Japan)

Two-Hand Control Device Design

【Two-Hand Control Principle】

Both buttons pressed simultaneously

Keeps hands out of the hazardous area

【Type (ISO 13851)】

Type I: single

Both buttons pressed simultaneously

Releasing either one → stop

Simple

Type II: manual reset

Pressed simultaneously + held

Release → stop

Type III: synchronised

Must be simultaneous (0.5sinside)according tooff

+hold

+requires reset after release

【Designrequirement】

1. Two buttons

Independently mounted

Spacing≥260mm (prevents one-handed operation)

Or fit a guard

2. simultaneity

Type III: 0.5spressed within

Invalid if timed out

3. Output

Dual-channel safety output

Maintained signal

4. return

Press again after release

Or manual reset

5. Position

The operator faces the hazardous area

One hand per button

【Safety level】

Generalrequirement: PL d

High risk: PL e

【DesignExample】

Presstwo-hand control:

1. Two buttons (300mm spacing)

2. Type III (synchronised, 0.5s)

3. safety relay (PL d)

4. Output→pressstart

5. Release → stop

6. mustheavynewtwo-hand control

【Combined with a Light Curtain】

Two-hand control: normal production

Light grid: entry in abnormal situations

Both can coexist

【Common Mistakes】

1. button spacing too small (can be operated with one hand)

2. no simultaneity requirement

3. single channel (no redundancy)

4. Button can be jammed

【Installation】

1. suitable height (standing1000~1500mm)

2. prevents accidental operation

3. clearly marked

4. Guard (prevents one-handed operation)

Pressure-Sensitive Mats and Edge Switches

【Pressure-Sensitive Safety Mat】

Function: laid on the floor, a person steps on it→triggers a stop

Principle: internal contacts, closed / opened under pressure

Application:

1. around the robot cell

2. AGV path

3. entry to the automatic line area

4. floor of the hazardous area

【Specification】

1. dimensions: 300×300 ~ 1000×1500mm

2. thickness: 8~15mm

3. Triggering force: 30~50kg (adult)

4. response time: <50ms

5. Life: 10⁶ cycles

6. protection: IP67

【Installation】

1. level floor

2. edges fixed

3. multiple mats joined together (cover the area)

4. concealed wiring

5. anti-slip surface

【Edge / Edge Switches】

Function: mounted on the edge of a moving part, hits an obstacle→standstill

Type:

1. pressure-sensitive edge

Rubber strip containing contacts

Triggered by pressure

2. pressure-sensitive bumper

Soft

Cushions and triggers

3. tactile strip

Flexible

Multi-point detection

Application:

1. automatic doors (anti-pinch)

2. AGV (anti-collision)

3. lift doors

4. robot end effector (anti-collision)

5. mobile platform

【Specification】

1. Length: custom made

2. triggering force: 10~50N

3. response: <20ms

4. protection: IP65

5. Life: 10⁶ cycles

【Safety level】

Used with a safety relay: PL d

Used with a safety PLC: PL e

【Selection】

1. triggering force (prevents accidental operation by children or small animals)

2. response time

3. dimensions

4. environment (IP/temperature)

5. mechanical life

6. safety level

Safety Door and Window Design

【Safety Door Design】

1. door types

a. hinged door

Commonly used

Opens towards the safe side

b. sliding door

Horizontal / vertical

Saves space

Requires a track

c. lifting door

Vertical lift

Motorised

Suitable for large openings

d. bi-parting door

Multi-panel

Large opening

2. door dimensions

a. maintenance door

600×1500mm (one person)

b. load/unload door

Depends on the workpiece

c. emergency exit

800×2000mm

3. material

Steel plate: high strength

Aluminium alloy: lightweight

Mesh: ventilated and see-through

Polycarbonate: see-through and impact resistant

4. interlock

Guard door switch (mechanical / magnetic / RFID)

Door locking (electromagnetic)

Safety level PL d/e

5. release

a. normal release

Door closed + machine stopped → can be opened

b. emergency release

Special tool / key

Emergency only

c. escape

Internal handle (to prevent trapping)

6. inspection window

Tempered glass/polycarbonate

Thickness (impact)

Position (so the hazard is visible)

【Safety window】

Fasteninspection window

Cannot be opened

Material:

Tempered glass: 5~10mm

Laminated glass: shatter resistant

Polycarbonate: impact resistant

PMMA : economical

【Door lockdesign】

1. electromagnetic lock

Lock open / unlock when energised

Locking force1000~5000N

Status feedback

2. Mechanical lock + interlock switch

Machinestrength

+electrical interlock

3. electromagneticrelease

De-energisedrelease (fail-safe)

Lock when energised

【Multi-door interlocking】

Several doors sharing one safety system

Any door open → standstill

All doors closed → start permitted

【Special Cases】

1. high risk

Electromagnetic lock+interlock+light curtain

Multiheavyprotection

2. maintenance door

Lock + key

Key withdrawn → door open → machine stops

3. Emergency

Internal escape device

Emergencylighting

Alarm

【Installation】

1. door frame rigidity

2. reliable hinges

3. Door lock alignment

4. limit switch position

5. adjustmargin

6. clearly marked

Design Measures Against Mechanical Hazards

【Mechanical hazardstype】

1. Crushing

2. Shearing

3. cutting/cut off

4. Entanglement

5. inhalation/entanglement

6. Impact

7. friction / wear

8. high-pressure injection

【Inherently safe design】

1. Eliminate sharp edges and corners

ChamferR>0.5mm

Radiused corners

Deburring

2. reducemoving parts

Enclose the moving parts

Reduceexposure

3. Reduce the speed / force

Speed < 0.25m/s (can be avoided)

Force < 150N (can be broken free)

4. increase the clearance

> body part (crush prevention)

or < clearance (inaccessible)

5. Reduce the effect of gravity

Prevents falling (brake)

Prevents overturning (center of gravity)

6. alternative energy

Pneumatic → mechanical (energy reduction)

Low voltage → high voltage

【Guard】

1. fastenprotection (see the separate entry)

2. Interlock Guarding (see the separate entry)

3. light curtain (see the separate entry)

4. two-hand control (see the separate entry)

5. safety mat

【Specific Protection】

1. rotating part

- shaft: sleeve guard

- coupling: enclosure

- gears / belts: fully enclosed

- chuck: guard + no start

2. Linear motion

- lead screw: telescopic bellows

- pneumatic cylinder: limit+buffering

- slide table: guard

3. Cutting zone

- machining: guard door + inspection window

- pressing: two-hand control + light curtain

4. Loading and unloading

- automatic loading (less human intervention)

- safety tooling

5. Maintenance point

- safety interlock

- lockde-energised

-apply tags (LOTO)

【Design Principles】

1. designphaseconsidersafety (inherently safe)

2. Protection takes precedence over warning

3. Multiple protection (redundancy)

4. fail-safe

5. considerreasonably foreseeable misuse

6. whole life cycle

7. Easy to maintain (without bypassing the safety)

【Typical machine safetydesign】

1. Press

Two-hand control + light curtain + interlocked door

Clutch and brake monitoring

Streak / repeat protection

2. Lathe

Chuck guard + interlock

Chip guarding

E-stop

3. Robot

Fence + guard door + light curtain

Speed limit (SLS)

Limit (SLP)

4. conveyor line

E-stop pull cord (along the line)

Guard

Noisecontrol

Related quick references: Safety FundamentalsSafety ControlEmergency Stop DesignSafety Distances

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL