Prevents the human body from reaching the hazardous area
1. reaching upwards
Hazard height ≥ 2700mm → out of reach
2. reaching over the guard (standing)
Guard heighth | hazard heightH | minimum distance
h=1000 | H=2400 | 100
h=1000 | H=2700 | 700
h=1200 | H=2700 | 600
h=1400 | H=2700 | 500
h=1600 | H=2700 | 400
h=1800 | H=2700 | 300
h=2000 | H=2700 | 200
h=2200 | H=2700 | 100
h=2400 | H=2700 | 0
3. reaching over the guard (seated)
h=700 | H=1600 | 200
h=700 | H=2400 | 850
h=700 | H=2700 | 950
4. reaching around
Reaching around the guard
The minimum distance depends on the guard height and the opening
Opening dimensionse (mm) | safe distanceSr (mm)
e≤4 | any value (a finger cannot enter)
4<e≤8 | ≥30
8<e≤25 | ≥120
25<e≤40 | ≥850
40<e≤250 | ≥900
Groove widthe (mm) | safe distance
4<e≤6 | ≥20
6<e≤8 | ≥30
8<e≤10 | ≥70
10<e≤12 | ≥120
12<e≤20 | ≥200
20<e≤30 | ≥850
Foot: minimum distance120mm (groove width)
Toe: 5mmopening
Leg: larger openings need larger distances
Body Part | Minimum clearance (mm)
Finger | 25
Hand | 100
Arm | 120
Leg | 250
Body | 500
Head | 300
a gap smaller than this is regarded as inaccessible
1. Openings in the fixed guard
2. Interlocked door distance
3. safety light curtaindistance
4. fence height
The guard has a rectangular opening15mm×5mm
Long side 15mm: from the slot table 12<e≤20 → Sr ≥ 200mm
Short side5mm: slot 4<e≤6 → Sr≥20mm
Take the larger value: Sr≥200mm
The hazard point must be at least200mm
Moving parts: safe distance = static distance + travel of the moving part
Rotating part:
Speedn, radiusr
Linear speedv = 2πrn/60
Stopping timet_stop
Safe distance = v×t_stop + static distance
Related quick references: Safety FundamentalsSafety ProtectionSafety ControlEmergency Stop Design