MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
Knowledge Base › Machine Safety Design › Emergency Stop Design
HomeModels
Table of contents

On this page

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Machine Safety Design · Emergency Stop Design (Quick Reference)

Emergency Stop Function Design (GB/T 16754)

【GB/T 16754emergency stop function】

1. emergency stop functionrequirement

a. takes priority over all other functions

b. operates without any other function

c. Must be self-locking (does not spring back when pressed)

d. must be reset manually

e. cuts off all hazardous energy

2. E-stop categories

0class: immediate power cut

Opens the main power directly

Suitable for: general machinery

1class: power off after controlled stop

Brake → stop → switch off

Suitable for: high speed / large inertia

2class: controlled stop, power remains on

Power stays on after stopping (e.g. servo)

Suitable for: cases requiring position holding

3. E-stop button

Red mushroom head

Yellow background

Self-locking (twist / pull to reset)

Button colours:

- E-stop: red on yellow

- stop: black/red

- start: green/white

【E-Stop Design】

1. button location

Easily reached by the operator

At least one at every operating position

At the hazard area entry

Remote control station

2. spacing

Reachable within 10m of the operator

Pressed within 10~15s

3. E-stop circuit

Dual-channel redundancy

Opens the main contactor directly

+safety relaymonitor

4. return

Manual

Twist / pull the button

+confirm with a reset button

5. Isolation

Category 0: main contactor

Category 1: brake → main contactor

Category 2: servo STO

【E-Stop Response Time】

Total time = press + signal transmission + control + braking

Requirement:

T_total < T_danger

T_danger — time to reach the hazard

Typical values:

Signal: <50ms

Controller: <50ms

Contactor opening: <50ms

Mechanical braking: depends on the load

【E-Stop Circuits】

1. 0class (directde-energised)

E-stop→safety relay→main contactor

Contactor opens → motor de-energised

2. 1class (controlled stop)

E-stop → inverter / servo → braking

After stopping → open the contactor

3. 2class (safe stop)

E-stop → servo STO

Motor decelerates to a stop

Power remains on (position)

【STO (Safe Torque Off)】

Safe Torque Off

Servo drive safety function

Triggered → motor torque-free (free stop)

Power is not cut

Comply withPL e/SIL3

Applications: Category 2 E-stop, robots, servo drives

【Restarting After an E-stop】

1. eliminate the cause of the E-stop

2. Reset the E-stop button (twist / pull)

3. press the reset button

4. check that it is safe

5. start manually

6. must not restart automatically

【E-Stop Testing】

Test the E-stop function periodically

1. press E-stop → confirm standstill

2. measure the response time

3. test every E-stop point

4. record

Related quick references: Safety FundamentalsSafety ProtectionSafety ControlSafety Distances

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL