1. emergency stop functionrequirement
a. takes priority over all other functions
b. operates without any other function
c. Must be self-locking (does not spring back when pressed)
d. must be reset manually
e. cuts off all hazardous energy
2. E-stop categories
0class: immediate power cut
Opens the main power directly
Suitable for: general machinery
1class: power off after controlled stop
Brake → stop → switch off
Suitable for: high speed / large inertia
2class: controlled stop, power remains on
Power stays on after stopping (e.g. servo)
Suitable for: cases requiring position holding
3. E-stop button
Red mushroom head
Yellow background
Self-locking (twist / pull to reset)
Button colours:
- E-stop: red on yellow
- stop: black/red
- start: green/white
1. button location
Easily reached by the operator
At least one at every operating position
At the hazard area entry
Remote control station
2. spacing
Reachable within 10m of the operator
Pressed within 10~15s
3. E-stop circuit
Dual-channel redundancy
Opens the main contactor directly
+safety relaymonitor
4. return
Manual
Twist / pull the button
+confirm with a reset button
5. Isolation
Category 0: main contactor
Category 1: brake → main contactor
Category 2: servo STO
Total time = press + signal transmission + control + braking
Requirement:
T_total < T_danger
T_danger — time to reach the hazard
Typical values:
Signal: <50ms
Controller: <50ms
Contactor opening: <50ms
Mechanical braking: depends on the load
1. 0class (directde-energised)
E-stop→safety relay→main contactor
Contactor opens → motor de-energised
2. 1class (controlled stop)
E-stop → inverter / servo → braking
After stopping → open the contactor
3. 2class (safe stop)
E-stop → servo STO
Motor decelerates to a stop
Power remains on (position)
Safe Torque Off
Servo drive safety function
Triggered → motor torque-free (free stop)
Power is not cut
Comply withPL e/SIL3
Applications: Category 2 E-stop, robots, servo drives
1. eliminate the cause of the E-stop
2. Reset the E-stop button (twist / pull)
3. press the reset button
4. check that it is safe
5. start manually
6. must not restart automatically
Test the E-stop function periodically
1. press E-stop → confirm standstill
2. measure the response time
3. test every E-stop point
4. record