Processes safety signals (E-stop/light curtain/guard door switch)
Outputs a safety control signal
Features:
1. Redundancy (dual channel)
2. force-guided contacts
3. fault detection
4. fail-safe (failure → contacts open)
5. manual / automatic reset
Mechanical connection, not spring
Coil de-energised → contacts open directly
Does not rely on a spring
Opens even if the contacts have welded
1. PNOZ sseries (basic)
PNOZ s1: 1E-stop
PNOZ s2: 1E-stop+return
PNOZ s3: 1light curtain
PNOZ s4: two-hand control
PNOZ s5: 2E-stop
PNOZ s7: expansion
PL: c/d
Contacts: 3NO+1NC
2. PNOZ mseries (modular)
Expandable
Multi-function
PL e
3. PNOZmulti (configurable)
Graphic configuration
Multi-function
PL e
Integrates multiple safety functions
1. Inputs (dual channel)
A1/A2 — E-stop1
A3/A4 — E-stop 2 (redundant)
2. feedback loop
Y1/Y2 — monitors the contactor state
3. return
S1/S2 — manual resetbutton
4. Output
13-14, 23-24, 33-34 — NO (safety)
41-42 — NC
1. Normal: input active → outputs close → machine runs
2. E-stop: input opens → outputs open → machine stops
3. Reset: must be manual (no automatic start)
4. Fault: cross-fault / welded contact detected → latched
1. Functions (E-stop / light curtain / door)
2. safety level (PL)
3. number of contacts
4. reset mode
5. delay (optional)
6. expansion (optional)
7. voltage
Requirement: E-stop+guard door+light curtain
PL d
3safety functions
SelectPNOZmulti:
- configurable with 3 functions
- PL e
- contacts expandable
- software configuration
Safety relay:
Simple
Fixed function
Suitable: a single / few functions
Safety PLC:
Flexible
Programmable
Suitable: multi-function / complex logic
High cost
1. does not reset
- abnormal input
- feedback loop
- welded contacts
2. operates too frequently
- unstable input signal
- vibration
3. output does not respond
- internal relay failure
- replace
Processes the safety functions
Comply withsafetystandard (IEC 61508)
Features:
1. Redundant CPU
2. self-diagnosing
3. force-guided separationOutput
4. safe communication
5. PL e/SIL3
1. Pilz PSS
PSS 4000: general purposesafetyPLC
PSSuniversal: distributed
2. Siemens S7-1500F / S7-1200F
F = Fail-safe
Integrated safety functions
PROFIsafecommunication
3. Siemens ET 200SP F
Distributed safety I/O
4. Allen-Bradley GuardLogix
Dual-CPU redundancy
5. Mitsubishi MELSEC QS
Safety PLC
1. E-stop handling
2. guard door monitoring
3. light curtain handling
4. two-hand control
5. safe speed monitoring
6. safe position monitoring
7. safe torque (STO)
8. logic interlock
1. safety program (separate)
2. standard program (standard)
3. safety+standardcancoexist
Safety programming languages:
- LAD (ladder diagram)
- FBD (function block)
- dedicated safety function blocks
1. PROFIsafe
Based on PROFINET/PROFIBUS
Siemens
Safety telegram + checksum
2. CIP Safety
Based on EtherNet/IP
Rockwell
3. openSAFETY
SERCOS III
B&R
4. CC-Link IE Safety
Mitsubishi
5. FSoE (Safety over EtherCAT)
Beckhoff
1. black channel (standard network + safety layer)
2. timestamp / sequence number
3. CRC check
4. watchdog
5. safety frame
Hard-wiring:
Advantages: simple, reliable
Disadvantages: many cables, inflexible
Safety fieldbus:
Advantages: fewer cables, flexible, diagnostics
Disadvantages: complex, expensive
1. number of safety functions
1~3: safety relay
3~10: small safety PLC
10+: safetyPLC+safety fieldbus
2. safety level
PL c/d: generalsafetyPLC
PL e: high performancesafetyPLC
3. communication
Integrated PROFINET: Siemens
Integrated CC-Link: Mitsubishi
4. I/O expansion
Local I/O
Distributed ET 200
1. safety inputs
- E-stop
- light curtain
- guard door switch
- safety mat
2. safety outputs
- safety relay
- safety semiconductor
3. speed / position monitoring
Encoder feedback
Siemens S7-1500F:
CPU 1515F-2 PN
ET 200SP F (distributed)
F-DI 8×24V (safety inputs)
F-DQ 8×24V (safety outputs)
F-AI (safety analogue)
Safety program:
- E-stop function block
- light curtain function block
- door monitoring function block
- speed monitoring function block
1. STO (Safe Torque Off)
Safe Torque Off
Trigger→electric motortorque-free
Motor free deceleration
Power is not cut (recoverable)
PL e/SIL3
Most common
2. SS1(Safe Stop 1)
Safe stop1
Controlled deceleration → 0 → STO
Triggered → decelerate as set → stop → STO
3. SS2(Safe Stop 2)
Safe stop2
Controlled deceleration → 0 → position held (SOS)
Position held after stoppingmonitor
4. SOS (Safe Operating Stop)
Safe operational stop
The motor stops but the position is held
Suitable for: cases requiring position holding
5. SLS (Safely Limited Speed)
Safe limited speed
Limithighestspeed
Suitable for: commissioning / maintenance
6. SLP (Safely Limited Position)
Safety limit
Limitpositionrange
7. SLT (Safely Limited Torque)
Safe torque limit
Limitmaximum torque
8. SDI (Safe Direction)
Safetydirection
Motion permitted in one direction only
9. SBT (Safe Brake Test)
Safe brakingtest
Periodic testingbrake
Servo drive:
Dual channelsafety inputs
Cut offelectric motorcurrent
Electric motortorque-free
The encoder still works (monitoring)
Response time:
STO activation: < 10ms
Motor free stop: depends on inertia / friction
1. E-stop (2class)
E-stop→STO
Motor free stop
Position held
2. guard dooropen
Door open → STO
Robotstop
Safety during maintenance
3. light curtaintrigger
Person enters → STO
Machine stop
4. commissioning mode
SLS (speed limit)
Permitted to run at low speed
A person can enter
Normal operation: standardcontrol
Safetytrigger: safety function
Example (robot cell):
1. Normal: robotoperation
2. Door open → SS1 (decelerate → stop)
3. reductionto0→STO (torque-free)
4. maintainmode→SLS (speed limit100mm/s)
5. E-stop → STO (immediate)
1. safety functionRequirement
StandardE-stop: STO
Precisionstop: SS1/SS2
Maintain: SLS
Limit: SLP
2. safety level
PL e/SIL3(mainstream)
3. drive support
Yaskawa Σ-7: STO / SS1
Panasonic A6: STO
Siemens S120: STO / SS1 / SS2 / SLS
4. communication
PROFIsafe/PROFINET
Integratedsafety
Siemens SINAMICS S120:
Safety Integrated
Functions: STO / SS1 / SS2 / SOS / SLS / SLP / SDI
Configuration: STARTER software
Certification: SIL3 / PL e
SSM (Safe Speed Monitor)
Monitorelectric motor/loadspeed
Overspeed → safe stop
1. dual encoders (redundant)
Two independent encoders
Comparisonspeed
Agreement → normal
Discrepancy → fault → standstill
2. single encoder + safety module
Encoder→safety module
Safety modulemonitor
3. inside the drive
Safety Integrated
STO+SS1+SS2+SLS
1. SLS (safe limited speed)
Limithighestspeed
Commissioning / maintenance
e.g. normal 5000rpm, SLS=500rpm
2. SSM (safe speed monitoring)
Speed = 0 → the door may be opened
Speed>0→door locking
3. SDI (safetydirection)
Only one direction permitted
Prevents reverse hazards
1. SLP (safety limit)
Limitpositionrange
Exceeded → stop
Softlimit (safety)
2. SOS (safe operational stop)
Position held after stopping
Monitor that the position does not change
Out of tolerance → alarm
3. safety cam
Position zone limit
e.g. operable only in the 180~270° range
Safety levelPL e:
Dual encoders (redundant)
Orsingleencoder+safetyassessment
Encodertype:
Incremental: a reference point is required
Absolute: direct position
Multi-turn: held when de-energised
Safetyencoder:
Heidenhain
Baumer
Renishaw
Position error: depends on the encoder resolution
17bit: 0.003°
23bit: 0.00004°
Positionout of tolerance:
In normal operation: ± 1 pulse
Out of tolerance → fault
Speed = position/time
Accuracy: 0.1~1rpm
If the drive does not support safety:
External safe speed monitor
Brands: Pilz, SICK, Siemens
Example: SICK DFS60
Dual encoder inputs
Speed / position monitoring
PL e
1. Centrifuge
High-speed rotation
Overspeed → hazardous
SSMmonitor
2. Crane
Speedlimit
Position limit (prevents over-travel)
3. Robot
SLS (low speed in maintenance mode)
SLP (operating range limiting)
4. winch
Overspeed protection
Over-travel protection
5. Rotary table
Positionlimit
Interlock
1. determinesafety function
2. Select the encoder (redundant)
3. selectsafety module/drive
4. configuration parameters (speed limit / limits)
5. validate the function
6. periodic testing
Lockout (lock)+Tagout (apply tags)
During maintenance / cleaning, isolate and lock the energy sources
Prevents inadvertent start-up
1. Electrical (main power supply)
2. Pneumatic (compressed air)
3. Hydraulic (pressure oil)
4. Mechanical (spring / gravity)
5. heat (steam / hot oil)
6. Chemical
7. Radiation
All energy sources must be isolated and locked
1. Notification
Notify all relevant personnel
Maintenance time / scope
2. Shutdown
According toNormalprocedurestandstill
Confirmstop
3. Isolation
Cut offallenergy
- electricity: main circuit breaker open
- air: close the valve + release the pressure
- fluid: close + release the pressure
- mechanical: release spring / support
4. Locking
Apply a lock at every isolation point
- lock: each person has their own
- several people: multi-lock hasp (one lock each)
- key: each person keeps their own
5. apply tags
Label:
- name
- date
- cause
- contact details
- warning (do not operate)
6. Validation
Attempt to start the machine (confirm that it does not start)
Test de-energised / depressurised
Validate with instruments
7. Work
Carrying out maintenance / cleaning
8. Completion
Account for the tools
Personnel evacuation
Restoreprotection
9. Release
Each person removes their own lock
The last person to remove their lock restores the energy
10. restore
Notify the relevant personnel
According toprocedurestart
1. Electrical lock
Circuit breaker lockout
Padlock
2. Valve lock
Ball valve / gate valve locks
3. general-purpose padlock
The key is unique
Different colours (department / person)
Several people working at the same time
One hasp per isolation point
Each personone lock hung on the hasp
All locks must be removed before operating
1. circuit breaker lock
Adapts to different circuit breakers
2. Plug lock
Power plug lock box
3. Valve lock
Different valve types
4. Chain lock
Large valves / pipework
1. Written procedure
A LOTO procedure for each machine
The steps are clearly defined
2. Training
Allpersonnel (operate/maintenance)
Before starting work
Annual refresher training
3. lock management
Issue / return
Marking
Sparekey (emergency)
4. Audit
Periodic auditsfollow
Improvement
5. record
LOTOfollowrecord
Abnormality handling
1. tag only without locking (can be bypassed)
2. common key (loses personal responsibility)
3. not verified (assume de-energised)
4. Missed energy source (electricity cut but air not)
5. Untrained
LOTO: during maintenancemanual
Interlock: automatic while running
Used together:
Interlock: normal operationsafety
LOTO: safety during maintenance
USAOSHA 1910.147(LOTOstandard)
China: GB/T 33579 (machine safety LOTO)
The company shall establish a LOTO policy in line with the applicable legislation