MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
Knowledge Base › Machine Safety Design › Safety Control
HomeModels
Table of contents

On this page

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Machine Safety Design · Safety Control (Quick Reference)

Safety Relay Working Principle and Selection

【Safety Relay Principle】

Processes safety signals (E-stop/light curtain/guard door switch)

Outputs a safety control signal

Features:

1. Redundancy (dual channel)

2. force-guided contacts

3. fault detection

4. fail-safe (failure → contacts open)

5. manual / automatic reset

【Force-guided separation】

Mechanical connection, not spring

Coil de-energised → contacts open directly

Does not rely on a spring

Opens even if the contacts have welded

【Pilz PNOZseries (mainstream)】

1. PNOZ sseries (basic)

PNOZ s1: 1E-stop

PNOZ s2: 1E-stop+return

PNOZ s3: 1light curtain

PNOZ s4: two-hand control

PNOZ s5: 2E-stop

PNOZ s7: expansion

PL: c/d

Contacts: 3NO+1NC

2. PNOZ mseries (modular)

Expandable

Multi-function

PL e

3. PNOZmulti (configurable)

Graphic configuration

Multi-function

PL e

Integrates multiple safety functions

【Wiring】

1. Inputs (dual channel)

A1/A2 — E-stop1

A3/A4 — E-stop 2 (redundant)

2. feedback loop

Y1/Y2 — monitors the contactor state

3. return

S1/S2 — manual resetbutton

4. Output

13-14, 23-24, 33-34 — NO (safety)

41-42 — NC

【Operating Logic】

1. Normal: input active → outputs close → machine runs

2. E-stop: input opens → outputs open → machine stops

3. Reset: must be manual (no automatic start)

4. Fault: cross-fault / welded contact detected → latched

【Selection】

1. Functions (E-stop / light curtain / door)

2. safety level (PL)

3. number of contacts

4. reset mode

5. delay (optional)

6. expansion (optional)

7. voltage

【Calculation Example】

Requirement: E-stop+guard door+light curtain

PL d

3safety functions

SelectPNOZmulti:

- configurable with 3 functions

- PL e

- contacts expandable

- software configuration

【Safety relayvssafetyPLC】

Safety relay:

Simple

Fixed function

Suitable: a single / few functions

Safety PLC:

Flexible

Programmable

Suitable: multi-function / complex logic

High cost

【Common Faults】

1. does not reset

- abnormal input

- feedback loop

- welded contacts

2. operates too frequently

- unstable input signal

- vibration

3. output does not respond

- internal relay failure

- replace

Safety PLC and Safety Fieldbus

【SafetyPLC】

Processes the safety functions

Comply withsafetystandard (IEC 61508)

Features:

1. Redundant CPU

2. self-diagnosing

3. force-guided separationOutput

4. safe communication

5. PL e/SIL3

【Mainstream Brands】

1. Pilz PSS

PSS 4000: general purposesafetyPLC

PSSuniversal: distributed

2. Siemens S7-1500F / S7-1200F

F = Fail-safe

Integrated safety functions

PROFIsafecommunication

3. Siemens ET 200SP F

Distributed safety I/O

4. Allen-Bradley GuardLogix

Dual-CPU redundancy

5. Mitsubishi MELSEC QS

Safety PLC

【Safety function】

1. E-stop handling

2. guard door monitoring

3. light curtain handling

4. two-hand control

5. safe speed monitoring

6. safe position monitoring

7. safe torque (STO)

8. logic interlock

【Programming】

1. safety program (separate)

2. standard program (standard)

3. safety+standardcancoexist

Safety programming languages:

- LAD (ladder diagram)

- FBD (function block)

- dedicated safety function blocks

【Safety fieldbus】

1. PROFIsafe

Based on PROFINET/PROFIBUS

Siemens

Safety telegram + checksum

2. CIP Safety

Based on EtherNet/IP

Rockwell

3. openSAFETY

SERCOS III

B&R

4. CC-Link IE Safety

Mitsubishi

5. FSoE (Safety over EtherCAT)

Beckhoff

【Safety Fieldbus Features】

1. black channel (standard network + safety layer)

2. timestamp / sequence number

3. CRC check

4. watchdog

5. safety frame

【Safety fieldbusvsHard-wiring】

Hard-wiring:

Advantages: simple, reliable

Disadvantages: many cables, inflexible

Safety fieldbus:

Advantages: fewer cables, flexible, diagnostics

Disadvantages: complex, expensive

【Selection】

1. number of safety functions

1~3: safety relay

3~10: small safety PLC

10+: safetyPLC+safety fieldbus

2. safety level

PL c/d: generalsafetyPLC

PL e: high performancesafetyPLC

3. communication

Integrated PROFINET: Siemens

Integrated CC-Link: Mitsubishi

4. I/O expansion

Local I/O

Distributed ET 200

【Safety I/O Modules】

1. safety inputs

- E-stop

- light curtain

- guard door switch

- safety mat

2. safety outputs

- safety relay

- safety semiconductor

3. speed / position monitoring

Encoder feedback

【Configuration Example】

Siemens S7-1500F:

CPU 1515F-2 PN

ET 200SP F (distributed)

F-DI 8×24V (safety inputs)

F-DQ 8×24V (safety outputs)

F-AI (safety analogue)

Safety program:

- E-stop function block

- light curtain function block

- door monitoring function block

- speed monitoring function block

STO / SS1 / SS2 / SLS Safety Functions

【Servo drive safety function】

1. STO (Safe Torque Off)

Safe Torque Off

Trigger→electric motortorque-free

Motor free deceleration

Power is not cut (recoverable)

PL e/SIL3

Most common

2. SS1(Safe Stop 1)

Safe stop1

Controlled deceleration → 0 → STO

Triggered → decelerate as set → stop → STO

3. SS2(Safe Stop 2)

Safe stop2

Controlled deceleration → 0 → position held (SOS)

Position held after stoppingmonitor

4. SOS (Safe Operating Stop)

Safe operational stop

The motor stops but the position is held

Suitable for: cases requiring position holding

5. SLS (Safely Limited Speed)

Safe limited speed

Limithighestspeed

Suitable for: commissioning / maintenance

6. SLP (Safely Limited Position)

Safety limit

Limitpositionrange

7. SLT (Safely Limited Torque)

Safe torque limit

Limitmaximum torque

8. SDI (Safe Direction)

Safetydirection

Motion permitted in one direction only

9. SBT (Safe Brake Test)

Safe brakingtest

Periodic testingbrake

【STOachieve】

Servo drive:

Dual channelsafety inputs

Cut offelectric motorcurrent

Electric motortorque-free

The encoder still works (monitoring)

Response time:

STO activation: < 10ms

Motor free stop: depends on inertia / friction

【Application Scenarios】

1. E-stop (2class)

E-stop→STO

Motor free stop

Position held

2. guard dooropen

Door open → STO

Robotstop

Safety during maintenance

3. light curtaintrigger

Person enters → STO

Machine stop

4. commissioning mode

SLS (speed limit)

Permitted to run at low speed

A person can enter

【Combination of safety functions】

Normal operation: standardcontrol

Safetytrigger: safety function

Example (robot cell):

1. Normal: robotoperation

2. Door open → SS1 (decelerate → stop)

3. reductionto0→STO (torque-free)

4. maintainmode→SLS (speed limit100mm/s)

5. E-stop → STO (immediate)

【Selection】

1. safety functionRequirement

StandardE-stop: STO

Precisionstop: SS1/SS2

Maintain: SLS

Limit: SLP

2. safety level

PL e/SIL3(mainstream)

3. drive support

Yaskawa Σ-7: STO / SS1

Panasonic A6: STO

Siemens S120: STO / SS1 / SS2 / SLS

4. communication

PROFIsafe/PROFINET

Integratedsafety

【Configuration】

Siemens SINAMICS S120:

Safety Integrated

Functions: STO / SS1 / SS2 / SOS / SLS / SLP / SDI

Configuration: STARTER software

Certification: SIL3 / PL e

Safe Speed and Position Monitoring

【Safe speed monitoring (SSM/SLS)】

SSM (Safe Speed Monitor)

Monitorelectric motor/loadspeed

Overspeed → safe stop

【Achievemethod】

1. dual encoders (redundant)

Two independent encoders

Comparisonspeed

Agreement → normal

Discrepancy → fault → standstill

2. single encoder + safety module

Encoder→safety module

Safety modulemonitor

3. inside the drive

Safety Integrated

STO+SS1+SS2+SLS

【Safe speed application】

1. SLS (safe limited speed)

Limithighestspeed

Commissioning / maintenance

e.g. normal 5000rpm, SLS=500rpm

2. SSM (safe speed monitoring)

Speed = 0 → the door may be opened

Speed>0→door locking

3. SDI (safetydirection)

Only one direction permitted

Prevents reverse hazards

【Safe position monitoring (SLP/SOS)】

1. SLP (safety limit)

Limitpositionrange

Exceeded → stop

Softlimit (safety)

2. SOS (safe operational stop)

Position held after stopping

Monitor that the position does not change

Out of tolerance → alarm

3. safety cam

Position zone limit

e.g. operable only in the 180~270° range

【Encoderrequirement】

Safety levelPL e:

Dual encoders (redundant)

Orsingleencoder+safetyassessment

Encodertype:

Incremental: a reference point is required

Absolute: direct position

Multi-turn: held when de-energised

Safetyencoder:

Heidenhain

Baumer

Renishaw

【Position monitoring accuracy】

Position error: depends on the encoder resolution

17bit: 0.003°

23bit: 0.00004°

Positionout of tolerance:

In normal operation: ± 1 pulse

Out of tolerance → fault

【Speed monitoring accuracy】

Speed = position/time

Accuracy: 0.1~1rpm

【Safety module (separate)】

If the drive does not support safety:

External safe speed monitor

Brands: Pilz, SICK, Siemens

Example: SICK DFS60

Dual encoder inputs

Speed / position monitoring

PL e

【Application Scenarios】

1. Centrifuge

High-speed rotation

Overspeed → hazardous

SSMmonitor

2. Crane

Speedlimit

Position limit (prevents over-travel)

3. Robot

SLS (low speed in maintenance mode)

SLP (operating range limiting)

4. winch

Overspeed protection

Over-travel protection

5. Rotary table

Positionlimit

Interlock

【Design】

1. determinesafety function

2. Select the encoder (redundant)

3. selectsafety module/drive

4. configuration parameters (speed limit / limits)

5. validate the function

6. periodic testing

LOTO (Lockout/Tagout) Procedure

【LOTO Concept】

Lockout (lock)+Tagout (apply tags)

During maintenance / cleaning, isolate and lock the energy sources

Prevents inadvertent start-up

【Energytype】

1. Electrical (main power supply)

2. Pneumatic (compressed air)

3. Hydraulic (pressure oil)

4. Mechanical (spring / gravity)

5. heat (steam / hot oil)

6. Chemical

7. Radiation

All energy sources must be isolated and locked

【LOTOprocedure】

1. Notification

Notify all relevant personnel

Maintenance time / scope

2. Shutdown

According toNormalprocedurestandstill

Confirmstop

3. Isolation

Cut offallenergy

- electricity: main circuit breaker open

- air: close the valve + release the pressure

- fluid: close + release the pressure

- mechanical: release spring / support

4. Locking

Apply a lock at every isolation point

- lock: each person has their own

- several people: multi-lock hasp (one lock each)

- key: each person keeps their own

5. apply tags

Label:

- name

- date

- cause

- contact details

- warning (do not operate)

6. Validation

Attempt to start the machine (confirm that it does not start)

Test de-energised / depressurised

Validate with instruments

7. Work

Carrying out maintenance / cleaning

8. Completion

Account for the tools

Personnel evacuation

Restoreprotection

9. Release

Each person removes their own lock

The last person to remove their lock restores the energy

10. restore

Notify the relevant personnel

According toprocedurestart

【Locks】

1. Electrical lock

Circuit breaker lockout

Padlock

2. Valve lock

Ball valve / gate valve locks

3. general-purpose padlock

The key is unique

Different colours (department / person)

【Multi-lock hasp】

Several people working at the same time

One hasp per isolation point

Each personone lock hung on the hasp

All locks must be removed before operating

【Special locks】

1. circuit breaker lock

Adapts to different circuit breakers

2. Plug lock

Power plug lock box

3. Valve lock

Different valve types

4. Chain lock

Large valves / pipework

【LOTOmanagement】

1. Written procedure

A LOTO procedure for each machine

The steps are clearly defined

2. Training

Allpersonnel (operate/maintenance)

Before starting work

Annual refresher training

3. lock management

Issue / return

Marking

Sparekey (emergency)

4. Audit

Periodic auditsfollow

Improvement

5. record

LOTOfollowrecord

Abnormality handling

【Common Mistakes】

1. tag only without locking (can be bypassed)

2. common key (loses personal responsibility)

3. not verified (assume de-energised)

4. Missed energy source (electricity cut but air not)

5. Untrained

【LOTOvsinterlock】

LOTO: during maintenancemanual

Interlock: automatic while running

Used together:

Interlock: normal operationsafety

LOTO: safety during maintenance

【Legislation】

USAOSHA 1910.147(LOTOstandard)

China: GB/T 33579 (machine safety LOTO)

The company shall establish a LOTO policy in line with the applicable legislation

Related quick references: Safety FundamentalsSafety ProtectionEmergency Stop DesignSafety Distances

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL