Design Pitfalls · Pneumatic Pitfalls (Quick Reference)

Pipe Diameter Too Small

Pitfall: Flow velocity in the main pneumatic line >8m/s

Correct practice: Main line velocity ≤6m/s, branch line ≤10m/s

Cause: A small pipe diameter causes a large pressure drop, leaving insufficient pressure at the end

Engineering design must follow the above principles to avoid product failure or safety accidents caused by design negligence.

Air Pipe Routing Too Low

Pitfall: Air pipes laid on the floor or at a low level

Correct practice: Route the pipes overhead with a drainage slope

Cause: Low locations collect water and dust, and the pipe holds standing water

Engineering design must follow the above principles to avoid product failure or safety accidents caused by design negligence.

No Air Dryer Fitted

Pitfall: No dryer fitted where high air quality is required

Correct practice: A refrigerated dryer or desiccant dryer must be fitted

Cause: Moisture in the compressed air damages pneumatic components

Engineering design must follow the above principles to avoid product failure or safety accidents caused by design negligence.

No Check Valve in the Vacuum System

Pitfall: No check valve between the vacuum generator and the suction cup

Correct practice: Fit a check valve or vacuum-hold valve at the suction cup end

Cause: The workpiece drops immediately when the air supply is cut

Engineering design must follow the above principles to avoid product failure or safety accidents caused by design negligence.

Ignoring Air Consumption Calculation

Pitfall: Air compressor capacity selected by rule of thumb

Correct practice: Precisely calculate the air consumption of each cylinder, and apply a safety factor of 1.3 to the total

Cause: Insufficient compressor capacity causes a pressure drop that affects production

Engineering design must follow the above principles to avoid product failure or safety accidents caused by design negligence.

Related quick references: Welding PitfallsCasting PitfallsShafting PitfallsSheet Metal PitfallsAssembly PitfallsHydraulic PitfallsShafting DesignHousing DesignWelded StructuresSheet Metal StructuresSpring DesignBolt ConnectionsBearing Arrangement

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL