MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
HomeModels
Table of contents

On this page

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Knowledge Base › Design Pitfalls › Bolted Connections

Design Pitfalls · Bolted Connections (Quick-Reference Handbook)

Bolt Protruding Too Far Beyond the Nut

Pitfall: the bolt protrudes >10mm beyond the nut

Consequence: wasted material / easy to bump into and cause injury

Correct practice: protrude 2~3 threads (about 3~5mm)

Bolt Hole Countersunk Too Deep

Pitfall: countersink depth >50% of the wall thickness

Consequence: excessive weakening of the wall thickness → insufficient strength

Correct practice: countersink depth ≤1/3 of the wall thickness

Bolts Placed on the Tension Flange

Pitfall: bolts placed on the tension flange of a beam

Consequence: superimposed stress in the tension zone → joint failure

Correct practice: place the bolts on the compression side or at the neutral axis

Bolt Spacing Too Small

Pitfall: bolt spacing < 1.5 times the bolt diameter

Consequence: no room to use a wrench / weakened strength between bolts

Correct practice: wrench clearance ≥d+6mm

Insufficient Bolt Thread Engagement (Cast Iron)

Pitfall: thread engagement depth in cast iron <2d

Consequence: stripped threads / insufficient joint strength

Correct practice: cast iron ≥2d / steel ≥1.5d / aluminum ≥2.5d

Unreliable Fastener Locking

Pitfall: relying only on a spring washer for locking under vibration

Consequence: a spring washer has limited locking ability → it loosens under prolonged vibration

Correct practice: use nylon lock nuts / anaerobic adhesive / double nuts / cotter pins in critical applications

No Clearance-Free Fit at the Bolt Shear Plane

Pitfall: using ordinary bolts (with clearance) as shear bolts

Consequence: clearance at the shear plane → impact / joint loosening

Correct practice: use fitted bolts in reamed holes for shear bolts (H7/m6 fit)

Bolted-Connection Design Pitfalls

① Pitfall: bolt too short (the threads are not fully engaged)

Correct practice: thread engagement depth ≥1.5d (steel), ≥2d (cast iron)

② Pitfall: no fatigue consideration for bolts under alternating load

Correct practice: reduce bolt stiffness and increase the stiffness of the clamped parts

③ Pitfall: bolts arranged too close together

Correct practice: space them evenly, pitch ≥5d

④ Pitfall: no control of bolt tightening torque

Correct practice: use a torque wrench and tighten to the specified torque

⑤ Pitfall: no locking provision on critical joints

Correct practice: spring washer / tab washer / anaerobic adhesive / cotter pin

⑥ Pitfall: using fitted bolts in ordinary bolt holes

Correct practice: reamed-hole fit H7/m6

⑦ Pitfall: no check when the load on a bolt group is uneven

Correct practice: calculate the load on each bolt and check the highest one

⑧ Pitfall: using ordinary bolts in a shear connection

Correct practice: use fitted bolts in reamed holes or high-strength bolts in a friction-type connection

Other quick references in this series:Welding PitfallsCasting PitfallsShaft System PitfallsSheet Metal PitfallsAssembly PitfallsHydraulic PitfallsPneumatic PitfallsShaft System DesignHousing DesignWelded StructuresSheet Metal StructuresSpring DesignBearing Arrangement

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL