Pitfall: the bolt protrudes >10mm beyond the nut
Consequence: wasted material / easy to bump into and cause injury
Correct practice: protrude 2~3 threads (about 3~5mm)
Pitfall: countersink depth >50% of the wall thickness
Consequence: excessive weakening of the wall thickness → insufficient strength
Correct practice: countersink depth ≤1/3 of the wall thickness
Pitfall: bolts placed on the tension flange of a beam
Consequence: superimposed stress in the tension zone → joint failure
Correct practice: place the bolts on the compression side or at the neutral axis
Pitfall: bolt spacing < 1.5 times the bolt diameter
Consequence: no room to use a wrench / weakened strength between bolts
Correct practice: wrench clearance ≥d+6mm
Pitfall: thread engagement depth in cast iron <2d
Consequence: stripped threads / insufficient joint strength
Correct practice: cast iron ≥2d / steel ≥1.5d / aluminum ≥2.5d
Pitfall: relying only on a spring washer for locking under vibration
Consequence: a spring washer has limited locking ability → it loosens under prolonged vibration
Correct practice: use nylon lock nuts / anaerobic adhesive / double nuts / cotter pins in critical applications
Pitfall: using ordinary bolts (with clearance) as shear bolts
Consequence: clearance at the shear plane → impact / joint loosening
Correct practice: use fitted bolts in reamed holes for shear bolts (H7/m6 fit)
① Pitfall: bolt too short (the threads are not fully engaged)
Correct practice: thread engagement depth ≥1.5d (steel), ≥2d (cast iron)
② Pitfall: no fatigue consideration for bolts under alternating load
Correct practice: reduce bolt stiffness and increase the stiffness of the clamped parts
③ Pitfall: bolts arranged too close together
Correct practice: space them evenly, pitch ≥5d
④ Pitfall: no control of bolt tightening torque
Correct practice: use a torque wrench and tighten to the specified torque
⑤ Pitfall: no locking provision on critical joints
Correct practice: spring washer / tab washer / anaerobic adhesive / cotter pin
⑥ Pitfall: using fitted bolts in ordinary bolt holes
Correct practice: reamed-hole fit H7/m6
⑦ Pitfall: no check when the load on a bolt group is uneven
Correct practice: calculate the load on each bolt and check the highest one
⑧ Pitfall: using ordinary bolts in a shear connection
Correct practice: use fitted bolts in reamed holes or high-strength bolts in a friction-type connection
Other quick references in this series:Welding PitfallsCasting PitfallsShaft System PitfallsSheet Metal PitfallsAssembly PitfallsHydraulic PitfallsPneumatic PitfallsShaft System DesignHousing DesignWelded StructuresSheet Metal StructuresSpring DesignBearing Arrangement