Pitfall: Spring index C=D/d<4
Consequence: Excessive stress on the inner side of the spring → premature fracture
Correct practice: C=4~16, normally C=5~8
Pitfall: The height-to-diameter ratio of a compression spring b=H0/D2>3.7 (both ends fixed) or >2.6 (one end fixed)
Consequence: The spring buckles and bends
Correct practice: When the ratio is large, add a guide rod or sleeve, or use multiple springs in series
Pitfall: The ends of a critical compression spring are not ground flat
Consequence: Uneven end face → the spring tilts / the load is uneven
Correct practice: Close the coils and grind the ends flat on critical springs (ground over ≥3/4 of a coil)
Pitfall: Ordinary spring steel selected for a fatigue duty (>10^6 cycles)
Consequence: Premature fatigue fracture
Correct practice: Use 50CrVA/60Si2MnA/stainless steel for high fatigue duty
A compression spring with H0/D2>3.7 (both ends fixed) or >2.6 (one end fixed) buckles and bends / add guidance / keep the guide clearance ≥2mm
C=D/d<4 → excessive stress on the inside (the Wahl factor K increases) → premature fracture / C>16 makes it easily unstable / C=5~8 recommended
The ends of a critical compression spring should be closed over 3/4 of a coil and ground flat / without grinding → uneven end face → tilting and uneven loading
The bend at the hook of a tension spring concentrates stress → fatigue fracture / add a transition radius (≥2d) or use an adjustable end
Disc spring stacks (facing versus laminated) differ in load and displacement characteristics / facing → greater travel / laminated → greater load / the wrong choice → does not meet the requirements
Spring materials: 65Mn (general), 50CrVA (high fatigue), 60Si2MnA (large section / high temperature), 304 (corrosion resistant) / the wrong choice → short fatigue life
① Pitfall: Spring index C<4
Correct practice: C=4~16
② Pitfall: Excessive height-to-diameter ratio of a compression spring
Correct practice: b≤3.7 (both ends fixed) or b≤2.6 (one end fixed)
③ Pitfall: Spring stiffness designed too low
Correct practice: Check the deflection under the working load
④ Pitfall: Spring fatigue life ignored
Correct practice: Use 50CrVA where high fatigue resistance is required
⑤ Pitfall: Unreasonable spring end structure
Correct practice: Close the coils and grind the ends flat
Related quick references: Welding PitfallsCasting PitfallsShafting PitfallsSheet Metal PitfallsAssembly PitfallsHydraulic PitfallsPneumatic PitfallsShafting DesignHousing DesignWelded StructuresSheet Metal StructuresBolt ConnectionsBearing Arrangement