Pitfall: housing wall thickness varies by >2×
Consequence: uneven cooling during casting → shrinkage porosity / internal stress / distortion
Correct practice: keep the wall thickness as uniform as possible, add a transition fillet R≥3mm at abrupt changes
Pitfall: a housing with a large flat face (>500×500mm) without stiffening ribs
Consequence: insufficient stiffness → distortion → poor gear mesh / bearing edge loading
Correct practice: add cross/hash-pattern ribs with rib height ≥3× the wall thickness
Pitfall: no coaxiality requirement for several bearing bores on the same axis
Consequence: the bores are not coaxial → difficult shaft assembly / bearing edge loading / premature failure
Correct practice: specify coaxiality ≤φ0.02~0.04mm
Pitfall: no relief groove at the root of a milled/bored face
Consequence: incomplete machining (an unmachined zone remains at the root), which affects assembly
Correct practice: provide a relief groove b×h=3×2mm at the root of a milled/bored face
Pitfall: the bearing-bore outer wall is <5mm from the housing edge
Consequence: insufficient strength → bearing seat deformation → change in bearing clearance
Correct practice: bearing-bore wall thickness ≥1.2× the bore diameter or ≥10mm
Pitfall: the sealing face on the housing joint is >20mm wide / no sealant groove added
Consequence: a large sealing area but insufficient clamping force → oil leakage
Correct practice: sealing face width 8~15mm, add a sealant groove / O-ring groove
Pitfall: no flatness requirement for the bearing-bore end face (the bearing mounting face)
Consequence: the bearing outer ring is clamped askew → reduced rotational accuracy
Correct practice: specify perpendicularity of the end face to the bearing-bore axis ≤0.02mm
Pitfall: oil passage diameter too small (<φ6mm) or turns too sharp
Consequence: oil passages clog / high resistance → poor lubrication
Correct practice: oil passage ≥φ6mm, turn radius R≥3mm, provide process holes at both ends
Pitfall: no aging treatment after welding a housing
Otherwise: welding residual stress → distortion after machining / Correct practice: anneal after welding (600~650℃) or vibration-age
Pitfall: housing fastening bolt spacing >400mm
Otherwise: insufficient clamping force on the joint face → oil leakage / Correct practice: bolt spacing ≤300mm (≤200mm when the pressure is >1MPa)
Pitfall: the bearing-bore centerline is not parallel to the mounting face
Otherwise: the shaft system is not parallel → gear edge loading → short life / Correct practice: specify parallelism ≤0.02mm
Other quick references in this series:Welding PitfallsCasting PitfallsShaft System PitfallsSheet Metal PitfallsAssembly PitfallsHydraulic PitfallsPneumatic PitfallsShaft System DesignWelded StructuresSheet Metal StructuresSpring DesignBolted JointsBearing Arrangement