Pitfall: The bearing housing is packed full of grease
Consequence: Sharp temperature rise (churning heat) → bearing seizure
Correct practice: Fill 1/3~1/2 (1/3 for high speed, 1/2 for low speed)
Pitfall: Mixing lubricants of different brands / viscosities
Consequence: Additive reaction → oil degradation / sediment precipitation
Correct practice: Top up with the same brand and grade / clean the tank before changing oil
Packing the bearing housing full of grease → churning heat → the grease thins out and is lost → poor lubrication → bearing seizure / fill only 1/3~1/2 of the housing
Greases of different brands or different bases (e.g. lithium base / calcium base) must not be mixed → separation, thinning or failure / when changing grease, clean the housing thoroughly
Select the oil grade according to the equipment manual / a high grade (high viscosity) for high temperature or low speed, a low grade for low temperature or high speed / the wrong grade → poor lubrication → equipment damage
Lubricating oil should be replaced regularly / hydraulic oil every 2000~4000h, gear oil every 3000~5000h / overdue → oxidation → loss of lubricating function
The highest point of the central lubrication piping should have a vent valve / without venting → air blocks the line → grease cannot reach the remote bearings → lubrication failure
An oil mist lubrication system should have an oil mist collector / without one → mist fills the area → environmental contamination / health hazard
① Pitfall: Wrong lubricant brand and grade selected
Correct practice: Select by speed / load / temperature
② Pitfall: Grease packed in excess
Correct practice: Fill the bearing to 1/3~1/2 of the space
③ Pitfall: Oil change interval too long
Correct practice: Change oil after 500h on first use, then every 3000h or as specified by the manufacturer
④ Pitfall: Unreasonable oil circuit layout
Correct practice: Avoid dead ends in the oil circuit and provide vent points
⑤ Pitfall: No monitoring on a central lubrication system
Correct practice: Fit a pressure switch and a flow indicator
Related quick references: Welding PitfallsCasting PitfallsShafting PitfallsSheet Metal PitfallsAssembly PitfallsHydraulic PitfallsPneumatic PitfallsShafting DesignHousing DesignWelded StructuresSheet Metal StructuresSpring DesignBolt ConnectionsBearing Arrangement