Pitfall: The oil tank is sealed without an air filter/breather
Consequence: Pressure difference inside and outside the tank as the level changes → the pump draws air / the tank deforms
Correct practice: Fit an air filter (10μm) in the tank cover
Pitfall: Suction line diameter smaller than the pump inlet port
Consequence: High suction resistance → cavitation → noisy pump / short life
Correct practice: Suction line diameter ≥ pump inlet port ×1.25
After bending or welding, hydraulic piping should be pickled (de-rusted, scale removed) → phosphated → blown clean / without this → weld slag and oxide enter the system → contamination
Galvanized pipe must not be used in hydraulic systems → the zinc coating peels off → particulate contamination → pump and valve damage / use seamless steel pipe (20 steel / 304 stainless)
The hydrostatic test pressure of a hydraulic system should be 1.5 times the working pressure / keep personnel clear during the test / not following this → hose burst and injury
Hydraulic oils of different brands and viscosities must not be mixed → additive reaction → sludge formation → system contamination / top up with the same brand and grade
The pipe fittings at the cylinder ports should be sealed with a copper washer or an O-ring / without it → oil seeps at the joint / a slow leak over time
The coaxiality of the pump and motor coupling should be ≤0.1mm / not checked → vibration, noise, coupling damage and pump bearing wear
Welded fittings on high pressure (>16MPa) hydraulic lines should be inspected after welding / without inspection → weld defects → hose burst
The pump should be unloaded when the hydraulic system is not working (relief valve unloading / solenoid valve neutral position unloading) / without unloading the motor consumes power at no load and the oil temperature rises
The hydraulic oil tank should have a baffle (return area → baffle → suction area) / without a baffle, bubbles from the return flow enter the suction area directly → cavitation, and cooling is poor
Hydraulic pipe clamps should be spaced ≤2m (steel pipe) and ≤1m (copper pipe or hose) / excessive spacing → pipe vibration → loosening of the fittings → oil leakage
The cylinder axis must be aligned with the direction of motion of the load / misalignment subjects the piston rod to side loads → seal wear and rod bending
Welded hydraulic piping should be pressure tested (1.5 times the working pressure) / without testing, weld leaks are not found and the system leaks in service
A change in hydraulic oil temperature changes the viscosity → unstable system operation / fit a cooler or a heater to keep the oil temperature at 40~55℃
Hydraulic quick couplings have a flow rating / selecting one that is too small creates throttling and system heating / select them from the line flow rate
Air mixed into the oil of a hydraulic system → slow response, stick-slip motion and system vibration / vent at every high point
Hydraulic steel tube should be cut square (angle ≤2°) and the ends chamfered and deburred / not square → the sealing ring is cut → oil leakage
The hydraulic system should have an oil temperature sensor and an alarm / without them an excessive oil temperature goes unnoticed → the oil ages rapidly → system failure
The hydraulic system should have a water-in-oil sensor / an emulsion (milky white) means the oil must be changed / without an alarm the fluid is used further → pump and valve damage
The precharge pressure of a bladder accumulator should be 0.6~0.8 times the minimum working pressure of the system / without precharge it loses its energy storage function
Water-glycol hydraulic fluid has special requirements for the seals (NBR is not suitable → use fluoroelastomer FKM) / the wrong fluid → seal failure
A hydraulic piping pressure test should hold the pressure for 10~30 minutes (pressure drop ≤5%) / without a hold, micro leaks are not found
Before replacing a hydraulic component, check the model and parameters on the nameplate / without checking the wrong part is ordered or it does not fit
The coaxiality of the hydraulic pump and motor should be ≤0.1mm (measured with a dial indicator) / too large → vibration and noise
Related quick references: Welding PitfallsCasting PitfallsShafting PitfallsSheet Metal PitfallsAssembly PitfallsHydraulic PitfallsPneumatic PitfallsShafting DesignHousing DesignWelded StructuresSheet Metal StructuresSpring DesignBolt ConnectionsBearing Arrangement