Pitfall: an H7 (clearance) fit between the bearing outer ring and the housing bore is used where the ring rotates
Consequence: the outer ring creeps relative to the housing bore → wear / heat
Correct practice: use a transition fit (J7/K7) for the rotating ring / H7 for the stationary ring
Pitfall: too few adjusting shims at the bearing end cover (excessive preload)
Consequence: excessive bearing preload → heat / shortened service life
Correct practice: leave a 0.05~0.15mm gap between the end cover and the bearing outer-ring face (measure, then fit the shims)
Other quick references in this series:Welding PitfallsCasting PitfallsShaft System PitfallsSheet Metal PitfallsAssembly PitfallsHydraulic PitfallsPneumatic PitfallsShaft System DesignHousing DesignWelded StructuresSheet Metal StructuresSpring DesignBolted JointsBearing Arrangement