Seal Lip Installed Facing the Wrong Way

Pitfall: The lip of a skeleton oil seal is installed facing outward (the wrong way)

Consequence: Oil leaks from the lip (the lip is supposed to wipe oil back to the inside)

Correct practice: Main lip toward the oil side (inside) / secondary lip toward the outside (dust sealing)

Insufficient Perpendicularity Between the Seal Face and the Shaft

Pitfall: Perpendicularity of the seal bore end face to the shaft axis >0.05mm

Consequence: The seal lip wears off-center → early failure

Correct practice: Specify perpendicularity ≤0.02mm / use a dedicated installation tool