Knowledge Base › Design Pitfalls › Automation

Design Pitfalls · Automation (Quick-Reference Handbook)

Environmental Factors Insufficiently Considered in Sensor Selection

Pitfall: choosing an ordinary sensor for a high-temperature/high-humidity/dusty environment

Consequence: frequent sensor faults (false triggering/damage)

Correct practice: choose a heat-resistant type for high temperature / IP67 for high humidity / an air-purge type for dust

Pneumatic System Without Post-E-Stop Reset Design

Pitfall: the pneumatic system does not auto-exhaust after an E-stop (the cylinder remains pressurized)

Consequence: the cylinder moves unexpectedly after the E-stop → personal injury

Correct practice: after an E-stop, de-energize double-solenoid valves / single-solenoid valves exhaust (spring return)

Insufficient Braking Resistor Capacity in the Servo System

Pitfall: a servo that accelerates/decelerates frequently has no braking resistor or one that is undersized

Consequence: DC bus overvoltage / drive fault

Correct practice: select the braking resistor + braking unit per the load inertia and deceleration frequency

Pneumatic System Without a Mid-Position Stop Function

Pitfall: using an ordinary 3-position 5-port closed-center valve for cylinder mid-position stopping

Consequence: the closed-center valve leaks → the cylinder drifts (inaccurate positioning)

Correct practice: use a cylinder with a locking device / clamp / mechanical stop

No Silencer on the Solenoid Valve Exhaust Port

Pitfall: no silencer on the solenoid valve/cylinder exhaust port

Consequence: exhaust noise >90dB (violates occupational health standards)

Correct practice: fit a coalescing silencer (pressure loss ≤0.01MPa)

No Air-Loss Protection on the Robot End-Effector Gripper

Pitfall: the pneumatic gripper has no air-loss protection (spring clamp / air release)

Consequence: the workpiece drops when air is lost → damage / injury

Correct practice: use a normally-closed gripper (spring-clamped / air-released)

AGV Navigation Tape Obscured

Pitfall: the AGV magnetic navigation strip is covered by metal objects (forklift/steel parts)

Consequence: AGV derailment / inaccurate positioning

Correct practice: keep the magnetic strip ≥200mm away from large ferromagnetic objects / use a metal-embedded type

Vacuum System Without Vacuum Retention

Pitfall: no check valve / non-return valve in the vacuum circuit

Consequence: as soon as the vacuum generator loses its air supply → the suction cups release the workpiece immediately

Correct practice: add a check valve to the vacuum circuit (to retain vacuum) / add a vacuum tank