Pitfall: housing wall too thin / no ribs / opening too large
Consequence: deformation → poor gear meshing / bearing eccentric loading
Correct practice: add ribs / reduce the opening / increase wall thickness
Pitfall: bearing bore closer than <5mm to the housing outer wall
Consequence: the bearing seat is too flexible → the bore deforms
Correct practice: wall thickness ≥10mm or ≥1.2 times the bore diameter
Pitfall: no cleanout opening for the casting sand in the housing cavity
Consequence: residual molding sand inside → enters bearings/gears and wears them
Correct practice: provide cleanout openings / process holes / easy sand removal
Pitfall: using an H7 (clearance) fit for a rotating bearing outer ring
Consequence: outer-ring creep / wear
Correct practice: J7/K7/M7 for a rotating ring, H7 for a stationary ring
Pitfall: the shaft shoulder on the bearing removal side is taller than the bearing inner-ring outer diameter
Consequence: the bearing cannot be removed (no purchase point for a puller)
Correct practice: shaft shoulder height ≤3/4 of the bearing inner-ring outer diameter
Pitfall: contact pattern not checked on the spherical/conical face of the bearing bore
Consequence: poor outer-ring contact → early failure
Correct practice: check the contact pattern with marking blue, >80%
Pitfall: the inner corners of the O-ring groove are sharp
Consequence: the O-ring is scored during installation → leakage
Correct practice: round the groove inner corners to R0.2~0.5mm
Pitfall: the oil seal lip lands on a keyway/oil hole in the shaft
Consequence: the lip jumps into the groove → leakage
Correct practice: keep the lip contact surface clear of keyways / oil holes / splines
Pitfall: long lubrication line / many elbows / small diameter
Consequence: grease never reaches the far end → the bearing runs dry and seizes
Correct practice: diameter ≥φ6mm / no more than 3 elbows / as short as possible
Pitfall: mineral oil incompatible with NBR seals (generally compatible)
Consequence: NBR swells → seal failure
Correct practice: NBR/FKM for mineral oil / FKM for synthetic oil
Pitfall: no label for the lubricant grade / oil change interval on the equipment
Consequence: wrong lubricant used → equipment damage
Correct practice: mark the oil brand/grade, viscosity, and oil change interval at the oil tank
Other quick references in this series:Welding PitfallsCasting PitfallsShaft System PitfallsSheet Metal PitfallsAssembly PitfallsHydraulic PitfallsPneumatic PitfallsShaft System DesignHousing DesignWelded StructuresSheet Metal StructuresSpring DesignBolted JointsBearing Arrangement