Pitfall: A proximity sensor is mounted too close to surrounding metal
Consequence: The sensor is falsely triggered by the metal of its own mounting bracket
Correct: For non-embeddable sensors, keep ≥2 times the sensing distance from surrounding metal
Pitfall: The lens of the photoelectric sensor has no anti-contamination protection
Consequence: Dust accumulates on the lens → unstable sensing / failure
Correct: Fit an air blow-off device / a dust cover / clean it periodically
Pitfall: The load cell is connected with flexible cable (unsecured)
Consequence: Cable bending / pulling → weighing accuracy affected
Correct: Use a dedicated load cell cable and secure it so that it carries no load
Pitfall: The encoder is connected with a rigid (non-flexible) coupling
Consequence: Shaft misalignment → encoder bearing damage
Correct: Use a flexible coupling for the encoder (bellows / diaphragm / spring disc)
Pitfall: The temperature sensor measures only one point / is installed in a dead corner
Consequence: The reading is not representative → misjudgment / inaccurate temperature control
Correct: Choose a representative measuring point (flowing / uniform area) / average several sensors
Design pitfall: a photoelectric sensor installed in a steam or dust environment without protection fails / select an IP67 rated sensor or add an air blow-off
Related quick references: Welding PitfallsCasting PitfallsShafting PitfallsSheet Metal PitfallsAssembly PitfallsHydraulic PitfallsPneumatic PitfallsShafting DesignHousing DesignWelded StructuresSheet Metal StructuresSpring DesignBolt ConnectionsBearing Arrangement