When the suction line is longer than 2m the suction resistance is high → the pump draws air, noise / shorten it as much as possible / increase the pipe diameter / or fit a charge pump
The hydraulic system must have a suction filter (100~200μm) and a return filter (10~25μm) / without them → particles circulate → pump and valve wear
A hydraulic hose bend radius <10 times the outside diameter causes kinking → restricted flow / shortened life / it should be ≥10 times / never install twisted
Hydraulic pipes should be laid at least 50mm above the floor, or in a trench / lying flat on the floor → easily stepped on, abraded and corroded
Both ends of a hydraulic cylinder should be fitted with an eye, a ball joint or a floating joint / without one → the piston rod takes side loads → bending and seal wear
A cylinder running faster than 0.1m/s must have cushioning (built into the cylinder or an external cushioning valve) / without cushioning → the piston strikes the head → shock and seal damage
The return line should have a back pressure valve (0.2~0.5MPa) / without back pressure → cylinder motion is not smooth → stick-slip
The highest point of the hydraulic system (cylinder and piping) should have a vent valve / without venting → air enters → system vibration and slow response
A multi-cylinder synchronized system should have synchronizing valves, synchronizing motors, or proportional valves plus closed-loop control / without them → the cylinders move inconsistently → the workpiece skews
Water-glycol and high-water-content hydraulic fluids impose special requirements on rubber seals (NBR is not compatible → use FKM) / using incompatible seals → leakage
Related quick references: Welding PitfallsCasting PitfallsShafting PitfallsSheet Metal PitfallsAssembly PitfallsHydraulic PitfallsPneumatic PitfallsShafting DesignHousing DesignWelded StructuresSheet Metal StructuresSpring DesignBolt ConnectionsBearing Arrangement