A long shaft (>500mm) with both bearings fixed (fixed end + fixed end) → thermal expansion → bearings jam / one end should be fixed and the other free to float
Shaft shoulder height ≥ 1.5~2 times the bearing inner-ring chamfer r / otherwise the inner-ring face does not seat → unreliable axial location
Housing bore shoulder height ≥ 1.5 times the bearing outer-ring chamfer r / insufficient → unreliable axial location of the outer ring
Use a transition fit (J7/K7) for the rotating ring and a clearance fit (H7) for the stationary ring / too tight → the outer ring deforms → clearance disappears → heating / too loose → creep
Back-to-back (DB): for cantilever shafts / moment loads; face-to-face (DF): for large spans / radial loads / the wrong choice → short life
CN (standard): general purpose / C3 (larger clearance): large inner-outer ring temperature difference / tight fit / C4 (even larger): high temperature / the wrong choice → unsuitable clearance → heating or noise
Leave removal space at the side of the bearing (≥15mm) / or provide threaded removal holes / without it → the bearing cannot be removed → destructive disassembly
Surface roughness of the bearing journal Ra ≤0.8μm / too rough → the bearing does not seat fully / wears the raceway / excessive running noise
Coupling installation coaxiality >0.05mm → additional dynamic load → premature bearing/seal failure / laser-align to ≤0.05mm
Threaded hole depth for the shaft-end locknut <1.5d → insufficient joint strength / the nut loosens under vibration / should be ≥1.5d (steel), ≥2d (cast iron)