Knowledge Base › Design Pitfalls › Automation Design

Design Pitfalls · Automation Design (Quick-Reference Handbook)

Cylinder Bore Oversized

An oversized cylinder bore → higher air consumption / higher cost / size the cylinder for a load ratio of 50~70% of actual thrust / do not blindly use a large bore

Solenoid Valve Cv Too Small

An undersized solenoid valve Cv → insufficient cylinder speed / sluggish action / select the valve Cv for the cylinder's required flow: Cv = cylinder air consumption / 1000

Insufficient Vacuum Suction Cup Safety Factor

Vacuum suction cup safety factor ≥4 for horizontal lifting and ≥8 for vertical / insufficient factor → the workpiece cannot be held → it drops → danger

Vacuum System Without Vacuum Retention (Check Valve)

The vacuum circuit should have a check valve plus a vacuum tank / without them → vacuum vanishes instantly when air is lost → the workpiece drops

Pneumatic Circuit Without a Manual Throttle

A throttle valve (exhaust throttling) should be fitted at the cylinder inlet/outlet / without it → speed cannot be adjusted → impact

External Bumper Required When the Cylinder Has No End Cushion

At cylinder speed >0.5m/s an external hydraulic bumper is required / no internal cushion and no external bumper → the piston slams the end cap → damage

No Air-Loss Protection on the Robot End-Effector Gripper

A pneumatic gripper should be normally closed (spring-clamped, air-released) / without air-loss protection → the workpiece drops when air is lost

Sensor Not Matched to the PLC Input Module (NPN/PNP)

The sensor output and PLC input module types must match (NPN to NPN, PNP to PNP) / mismatch → the signal cannot be read

Pneumatic System Without Spare Air Ports

Reserve 1~2 spare air ports with shut-off valves in the air circuit design / without them → adding pneumatic components later requires re-piping

Moving Parts Not Reset After E-stop

After the E-stop is released the equipment must not restart by itself / manual reset is required (safety circuit) / automatic reset → safety hazard

Safety Door Without a Locking Device

A safety door should have a door lock (solenoid/mechanical) plus a safety switch / without it → the equipment can start with the door ajar → danger

Sensor Cables Not Secured

Sensor cables should be secured / unsecured → the cable flexes and breaks during motion → signal loss / secure it with a drag chain or cable clamps

Vacuum Suction Cup Size Unsuitable for the Workpiece

A small cup on a large workpiece → cannot hold it / a large cup on a small workpiece → interference / cup diameter = workpiece maximum width × 0.8

Sensor Cables on Moving Parts Without a Drag Chain

Sensor cables and power cables on moving parts should run inside a drag chain / otherwise → repeated flexing → conductor breakage → signal loss

Insufficient Safety Distance Between the Robot and Surrounding Equipment

Robot working envelope closer than <500mm to people/equipment → collision risk / provide a safety fence plus a safety light curtain

Inaccurate AGV Positioning Without Reflectors

AGV laser navigation should have reflective strips / without them → positioning error >±50mm → collision / add reflective posts or floor markers

Other quick references in this series:Welding PitfallsCasting PitfallsShaft System PitfallsSheet Metal PitfallsAssembly PitfallsHydraulic PitfallsPneumatic PitfallsShaft System DesignHousing DesignWelded StructuresSheet Metal StructuresSpring DesignBolted JointsBearing Arrangement