Design Pitfalls · Pneumatic System Design (Quick Reference)

Air Service Unit Installed Too Far Away

The service unit (filter / regulator / lubricator) should be installed within 5m of the pneumatic equipment inlet / too far → line pressure loss → insufficient pressure / poor operation of downstream equipment

Air Lines Laid Across Walkways

Air lines laid across pedestrian or vehicle aisles get stepped on and crushed → air leakage / run them overhead, along walls or along the equipment

Improper Air Line Selection (Material and Outside Diameter)

Tube material: PU (general), nylon (pressure resistant), PTFE (chemical resistant) / an insufficient outside diameter gives low flow → slow cylinder speed / size the line from the air consumption

Main Air Supply Line Too Small

Size the main supply line so that the maximum simultaneous air velocity is ≤6m/s / too small → insufficient supply → low pressure at the most distant cylinder

Quick Couplings Not Checked After Installation

After fitting a push-in coupling, pull the tube to confirm that it is locked / without checking → the tube pulls out → air leakage and downtime