Before maintenance on a pneumatic circuit, vent the pressure manually / without venting → high-pressure air sprays out when a pipe is removed → injury / fit a manual shut-off valve at the air inlet
Tube colors should be standardized (generally blue PU tube for pneumatics, red for vacuum, transparent for water) / mixed colors → wrong disconnection during maintenance → accidents
Above 0.5m/s even the built-in cushioning of a cylinder may be insufficient / add an external hydraulic buffer (ACE/SMC) / without cushioning → impact noise
① Pitfall: Pipe diameter too small
Correct practice: Main line velocity ≤6m/s, branch line ≤10m/s
② Pitfall: Supply air quality ignored
Correct practice: A filter and a dryer must be fitted
③ Pitfall: Improper cylinder cushioning adjustment
Correct practice: Adjust the cushioning valve according to the load and speed
④ Pitfall: Air lines routed too low
Correct practice: Avoid laying them on the floor and allow for drainage slope
⑤ Pitfall: No check valve in the vacuum system
Correct practice: Fit a check valve between the vacuum generator and the suction cup
A tube outside diameter that does not match the quick coupling causes air leakage and disconnection / use push-in fittings and tubes of the same brand and specification
A grease-lubricated cylinder (with grease in the front section) must not be used with an oil mist system / the grease is washed out → lubrication loss → shortened life
Vacuum systems need a dedicated vacuum hose (with reinforcement ribs / anti-collapse) / a standard air tube collapses once the vacuum is slightly higher → the air circuit is blocked
The total air demand of the equipment should be ≤80% of the compressor capacity / beyond that → the system pressure keeps dropping → poor operation of the equipment / add an air receiver to smooth this out
The air line route should be as short as possible, with few elbows and an elbow radius ≥10 times the outside diameter / an unreasonable route causes a large pressure loss and insufficient pressure at the end
A standard vacuum cup on a workpiece surface with an oil film or cutting fluid cannot hold it → the workpiece slips off / use a bellows cup or add anti-slip grooves
The air consumption of a vacuum generator is about 0.5~1.5Nm³/min / select the number of vacuum generators and the compressor capacity from the total air demand
Different air circuits should use different colored tubes (blue for working air, red for vacuum, transparent for water) / without distinction → wrong disconnection during maintenance → accidents
Multiple solenoid valves should be mounted on a manifold (base plate) / connecting them separately gives many pipe runs, many leak points and a high cost
A pneumatic system should have a safety valve (set pressure ≤1.1 times the working pressure) / without it → overpressure → the piping bursts
The minimum bend radius of an air tube should be ≥10 times the outside diameter / too small → the tube kinks → the air circuit is blocked
Cylinders that act at different times should be on separate air circuits / sharing one circuit → they interfere with each other
Related quick references: Welding PitfallsCasting PitfallsShafting PitfallsSheet Metal PitfallsAssembly PitfallsHydraulic PitfallsPneumatic PitfallsShafting DesignHousing DesignWelded StructuresSheet Metal StructuresSpring DesignBolt ConnectionsBearing Arrangement