MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
Knowledge Base › Product Design › Hot Runner System
HomeModels
Table of contents

On this page

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Product Design · Hot Runner System (Quick Reference)

Hot Runner System Structure and Classification

【Hot Runner System Components】

① Hot runner plate (manifold): distributes the melt to each nozzle

② Hot nozzle: delivers the melt into the cavity

③ Heating elements: heating rods / heating coils / cartridge heaters

④ Temperature control system: thermocouple + temperature controller

【Classification】

By nozzle type: open type / valve gate type

By heating method: internal heating / external heating

By runner plate temperature: hot runner / warm runner

【Open Nozzle】

Simple structure, small gate residue mark

Application: general injection moulding, not suitable for low viscosity plastics

【Valve Gate Nozzle】

The gate opening and closing can be controlled, leaving no gate mark

Application: parts with strict appearance requirements / synchronised multi-cavity filling

Cost: 2~3 times the open type

Hot Runner Temperature Control System Design

【Temperature Control Accuracy Requirements】

General injection moulding: ±2~5℃

Precision injection moulding: ±1℃

The nozzle-to-nozzle temperature difference on a multi-cavity mould ≤3℃

【Thermocouple Types】

J type (iron-constantan): range 0~750℃, the most common

K type (chromel-alumel): range 0~1200℃, for high temperature

【Heating Power】

Hot runner plate: 100~200W per kg of weight

Hot nozzle: 100~500W each (depending on the size)

【Heater Installation】

Fits the runner plate hole with H7/h6

Too large a gap → poor heat transfer; too small → difficult assembly and disassembly

【First Heat-up】

The temperature must be raised slowly (10~20℃/min)

Rapid heating burns out the heating rods or distorts the runner plate

Hot Runner Gate Types and Selection

【Hot Tip Gate (most common)】

The nozzle tip has a conductive tip that keeps the gate molten

Gate diameter: φ0.5~2.0mm

Applicable: ABS/PC/PP/PA

Not applicable: high viscosity materials (PVC/POM)

【Valve Gate】

The valve needle is driven pneumatically or hydraulically to open and close the gate

Gate diameter: φ0.8~3.0mm

Advantages: small gate mark / controllable filling sequence / prevents drool

Application: appearance parts / sequential filling / multi-cavity moulds

【Edge Gate】

Feeds from the side of the part

Application: multi-cavity moulds / side wall feeding

【Top Gate】

Feeds from the center of the top of the part

Application: cylindrical parts / single cavity moulds

【Selection Recommendations】

High appearance requirements → valve gate

Multi-cavity identical parts → hot tip gate

Sequential filling (such as automotive door panels) → valve gate with sequence valve control

Common Hot Runner Fault Analysis and Remedies

【Burnt Out Heater】

Causes: ① the first heat-up is too fast ② poor fit between the heater and its hole (local overheating) ③ a failed thermocouple causes the temperature to run away

Remedies: ① replace the heater ② clean the oxide layer inside the heater hole ③ check the thermocouple position

【Runner Plate Leakage】

Causes: ① a damaged seal ② insufficient bolt preload on the runner plate ③ thermal expansion causes the seal to fail

Remedies: ① replace the seal (copper gasket / high temperature O-ring) ② retighten to the specified torque ③ preheat to the working temperature and tighten a second time

【Blocked Gate】

Causes: ① the plastic has degraded and carbonised ② foreign matter has entered ③ the temperature at the gate is too low

Remedies: ① flush the runner (with PP/PE) ② polish the gate ③ raise the temperature in the gate area

【Uneven Filling Between Nozzles】

Causes: ① the nozzle temperatures are inconsistent ② the runner is unbalanced ③ an individual nozzle is blocked

Remedies: ① calibrate each temperature control zone ② check the actual temperature of each nozzle ③ clear the blocked nozzle

Hot Runner Sealing and Installation Specification

【Sealing Methods】

① O-ring sealing: temperature resistant to ≤200℃, suitable for general plastics

② Copper gasket sealing: temperature resistant to ≤400℃, suitable for high temperature engineering plastics

③ Metal sealing (tapered / flat): the seal does not need replacement

【Installation Torques】

Nozzle to runner plate connection: 20~40N·m

Nozzle to mould connection: 30~60N·m

Runner plate fixing bolts: the standard torque for the size

【Installation Cautions】

① Clean all contact surfaces before installation

② O-rings and copper gaskets must be replaced at every disassembly

③ Apply thermal conductive silicone grease when installing the heating elements

④ After the first installation, preheat to the working temperature and retighten the bolts

【Insulation】

① The hot runner plate must be thermally insulated from the mould (an air gap of 5~10mm)

② Fit pressure blocks (insulating material)

③ Prevent heat from reaching the injection machine platens

Related quick references: Injection Molding ProcessStamping ProcessDie Casting ProcessSurface TreatmentMold StructureRunner SystemCooling SystemMold MaterialsPlastic MaterialsInjection Molding DefectsMold MachiningAutomotive MoldsForging Dies