Common Faults · Instruments / Sensors (Quick-Reference Handbook)

Thermocouple inaccurate temperature

[Thermocouple inaccurate temperature]

[Phenomenon] Display temperature deviates greatly from actual

[Possible Causes]

(1) Thermocouple aging (thermal EMF drift); (2) Extension wire mismatch with thermocouple; (3) Cold-junction compensation failure; (4) Probe fouling / oxidation

[Corrective Measures]

(1) Replace thermocouple (periodic calibration); (2) Use same-model extension wire; (3) Check cold-junction temperature; (4) Clean probe

PT100 RTD fault

[PT100 RTD fault]

[Phenomenon] Abnormal resistance / open circuit

[Possible Causes]

(1) Platinum wire breaks (vibration); (2) Terminal loose / oxidized; (3) Insulation drops (moisture)

[Corrective Measures]

(1) Replace PT100; (2) Tighten / clean terminals; (3) Dry out

Flow meter reads low

[Flow meter reads low]

[Phenomenon] Actual flow high but display low

[Possible Causes]

(1) Electrode fouling (electromagnetic); (2) Pipe not full; (3) Turbine jammed (turbine meter); (4) Converter parameter drift

[Corrective Measures]

(1) Clean electrodes; (2) Ensure full-pipe installation; (3) Clean turbine / add filter; (4) Re-calibrate converter

Flow meter reads high

[Flow meter reads high]

[Phenomenon] Actual flow low but display high

[Possible Causes]

(1) Zero drift; (2) Bubbles in fluid (electromagnetic meter); (3) Pipe vibration (vortex meter)

[Corrective Measures]

(1) Zero calibration; (2) Add de-bubbling / venting; (3) Add pipe supports to damp vibration

Level gauge reads stuck

[Level gauge reads stuck]

[Phenomenon] Level changes but gauge value unchanged

[Possible Causes]

(1) Probe fouling / coking; (2) Guided-radar antenna adherent; (3) Float stuck (float type)

[Corrective Measures]

(1) Clean probe; (2) Clean antenna; (3) Clean float / guide rod

Pressure gauge pointer jitter

[Pressure gauge pointer jitter]

[Phenomenon] Pointer vibration amplitude > 1/3 division

[Possible Causes]

(1) Pulsation in line (pump / compressor); (2) Installation near elbow / valve; (3) Internal gear loose

[Corrective Measures]

(1) Add damper / needle valve; (2) Add buffer tube before gauge; (3) Replace / repair gauge

Pressure gauge fails to return to zero

[Pressure gauge fails to return to zero]

[Phenomenon] Pointer fails to return to zero after depressurizing

[Possible Causes]

(1) Bourdon tube fatigue / permanent deformation; (2) Sector gear stuck; (3) Hairspring detached

[Corrective Measures]

(1) Replace gauge; (2) Clean gear / oil; (3) Replace movement

Gas analyzer false alarm

[Gas analyzer false alarm]

[Phenomenon] Alarm with normal concentration

[Possible Causes]

(1) Sensor disturbed by humidity / temperature; (2) Filter dirty (line blockage); (3) Calibration expired

[Corrective Measures]

(1) Add preconditioning (dehumidify / thermostatic); (2) Replace filter; (3) Re-calibrate

Vibration sensor signal interrupted

[Vibration sensor signal interrupted]

[Phenomenon] Online monitoring data interrupted

[Possible Causes]

(1) Sensor cable broken (long-term bending); (2) Loose connector; (3) Sensor damaged

[Corrective Measures]

(1) Replace cable (flexible / fixed); (2) Lock connector; (3) Replace sensor

Load cell zero offset

[Load cell zero offset]

[Phenomenon] Output not zero at no load

[Possible Causes]

(1) Sensor overloaded (plastic deformation); (2) Mounting base deformed; (3) Sensor subjected to side load; (4) Temperature change (thermal zero drift)

[Corrective Measures]

(1) Replace sensor (damage not recoverable); (2) Reinforce base; (3) Adjust mounting (remove side load); (4) Auto-zero / temperature compensation