Hydraulic cylinder stick-slip

[Phenomenon] Hydraulic cylinder moves unevenly at low speed

[Cause]

(1) Air in cylinder

(2) Uneven seal friction (stick-slip)

(3) Poor lubrication

(4) High guideway friction

(5) Supply pressure fluctuation

[Countermeasures]

(1) Bleed air

(2) Replace low-friction seal

(3) Improve lubrication

(4) Improve guiding accuracy

(5) Add accumulator to stabilize pressure

Hydraulic system oil temperature too high

[Phenomenon] Oil temperature exceeds 60°C, system performance degrades

[Cause]

(1) Insufficient tank volume

(2) Cooler blockage or insufficient capacity

(3) Relief valve pressure set too high

(4) Excessive line pressure loss

(5) High ambient temperature

[Countermeasures]

(1) Increase tank volume

(2) Clean or enlarge cooler

(3) Optimize system pressure setting

(4) Optimize line layout

(5) Add cooling loop