Common Faults · Pneumatic Faults (Quick-Reference Handbook)

Pneumatic directional valve fails to actuate

[Phenomenon] Valve spool does not move after solenoid energized

[Cause]

(1) Insufficient voltage or burned coil

(2) Spool stuck (foreign object / oil sludge)

(3) Pilot air path blocked

(4) Spring broken

(5) Seal aging and swelling

[Countermeasures]

(1) Check supply voltage

(2) Clean valve spool

(3) Clean pilot air path

(4) Replace spring

(5) Replace seal

Vacuum suction cup cannot hold workpiece

[Phenomenon] Suction cup cannot stably hold workpiece

[Cause]

(1) Insufficient vacuum (generator undersized)

(2) Suction cup worn or broken

(3) Workpiece surface has holes / oil

(4) Line leakage

(5) Workpiece too heavy or cup diameter too small

[Countermeasures]

(1) Increase vacuum generator

(2) Replace suction cup

(3) Clean workpiece surface

(4) Check line airtightness

(5) Increase cup diameter or add more cups