Common Faults · Product Defects (Quick-Reference Handbook)
Injection-molded part warpage analysis
[Phenomenon] Part bends / twists / exceeds flatness after ejection
[Cause] (1) Uneven mold temperature distribution; (2) Large wall-thickness variation (thick sections shrink more than thin); (3) Filling orientation causes anisotropy; (4) Insufficient cooling time
[Diagnosis] Measure ejection temperature at each location, check cooling channels for blockage, measure wall thickness
[Remedy] Balance mold temperature, optimize gate location, increase cooling time 20%~50%, anneal at 60~80°C × 2~4 h
Other related quick references:Welding defectsHydraulic systemPneumatic systemMotor electricalEquipment faultsMotor faultsStructural part faultsSensor faultsElectrical faultsQuick diagnosisMechanical component faultsBearing faultsGear faultsHydraulic / pneumatic valves